User manual ZONET ZFS3228E QUICK INSTALLATION GUIDE
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZONET ZFS3228E. We hope that this ZONET ZFS3228E user guide will be useful to you.
Manual abstract: user guide ZONET ZFS3228EQUICK INSTALLATION GUIDE
Detailed instructions for use are in the User's Guide.
[. . . ] 8-Port Gigabit Switch
ZFS3228E
Quick Installation Guide
Features Plug & Play Complies with IEEE802. 3, IEEE802. 3u, IEEE802. 3ab, IEEE802. 3x standards NWAY Auto-negotiation support, Auto-Sense the transmission speed, half/full duplex 8 ports 10/100/1000M Auto-Sense, Auto-MDI/MDIX Adopt IEEE802. 3x flow control for full-duplex and backpressure for half-duplex Non-blocking wire-speed transfer Adopt store and forward structure MAC address auto learning Support IEEE802. 3x for broadcasting storm control Package Contents One 8-Port Gigabit Switch One Quick Installation Guide One Power Adapter Four rubber pad Front Panel LED lights panel
Rear Panel RJ45 ports
Side Panel Ventilation and cooling holes Please make sure there is no substance block up these holes, and leave enough space at the two side of the switch, so the switch can have a proper ventilation and cooling to avoid high heat inside the switch, which may cause improper working of the system.
LED Power 10/100M Link
Status Operation Green Lit: Power is on
Lit: Indicates a 10/100M device is connected Green Flash: the port is transmitting/receiving data Not lit: Indicates there's a 10M device or no device connected Lit: Indicates this port is working under full duplex mode Full Duplex Green Flash: the port is working under half duplex mode (FDX/COL) Not lit: Indicates this port is working under half duplex mode Lit: Indicates a 1000M device is connected 1000M Link/Act Green Flash: the port is transmitting/receiving data Not lit: Indicates there's a 10/100M device or no device connected
Installation 1. [. . . ] Install the four rubber pad one the four bottom corner of the switch to avoid scratch at the bottom surface. When install the switch on the rack, make sure to fix tight it on the rack with the screw. The cable distance between the Switch and other IEEE802. 3 compatible network device should not exceed 100 meter Make sure the wiring is correct, it can be used Category 3/4/5 cable in 10 Mbps operation. To reliably operate your network at 100/1000Mbps, you must use an Unshielded/shielded Twisted-Pair (UTP/STP) Category 5 cable, or better Data Grade cabling. While a Category 3 or 4 cable may initially seem to work, it will soon cause data loss All kinds of IEEE802. 3 compatible network device (Hub, Switch, PC)can connect to the Switch by using straight-through wires or crossover wires because of Switch's auto MDIX function Troubleshooting We always do our very best to deliver good quality product. Most problems come from disconnected cable, faulty cable, exceeding cable length, or a malfunctioning LAN card. If the Power LED is not lit after the power is turned on, check the power source and power cable. If the problem still can not be resolved, call your local supplier to change the power adapter or the whole Switch unit. [. . . ] Notice: If the problem still can not be solved, have your software/hardware configuration and error indications from LEDs, call your local supplier for further assistance.
12-086-00599 Rev:00 [. . . ]