User manual WHIRLPOOL WED4616FW DIMENSION GUIDE
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHIRLPOOL WED4616FW. We hope that this WHIRLPOOL WED4616FW user guide will be useful to you.
You may also download the following manuals related to this product:
WHIRLPOOL WED4616FW USE & CARE GUIDE (4427 ko)
WHIRLPOOL WED4616FW INSTALLATION GUIDE (4925 ko)
WHIRLPOOL WED4616FW WARRANTY INFORMATION (297 ko)
Manual abstract: user guide WHIRLPOOL WED4616FWDIMENSION GUIDE
Detailed instructions for use are in the User's Guide.
[. . . ] Electric Dryer
PRODUCT MODEL NUMBERS WED4800B, WED4810B, WED4850B, WED4870B, WED5000D, WED4810E, WED4815E, WED4915E, WED4975E, WED4616F, WED4916F
Dryer Dimensions
Wide opening side-swing door 29" (737 mm) 29" (737 mm) Wide opening hamper door 133/4" (349 mm)
22 / " (578 mm)
3 4
27 / " (705 mm)
3 4
273/4" (705 mm)
433/8" (1102 mm)
433/8" (1102 mm)
1/2" (13 mm)
11/2" (38 mm)
NOTE: Leveling legs should be 1/2" (13 mm) (to match height of 3. 6 cu. [. . . ] Closet door with vents
*Additional spacing recommended
W10562358A 05/2015
ELECTRICAL REQUIREMENTS
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz. , AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. Connect to an individual branch circuit.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
The Vent System Chart provides venting requirements that will help achieve best drying performance.
Vent System Chart
Number of 90° turns or elbows 0 1 2 3 4 Type of vent Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Box/louvered hoods 64 ft. (6. 4 m)
Exhaust hoods: Recommended Styles:
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Vent System Chart (Long Vent Models Only)
Number of 90° turns or elbows 0 1 2 3 4 5 Type of vent Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Box/louvered, or Angled hoods 120 ft. (21. 3 m)
Determine vent path:
■■ Select route that will provide straightest and most direct
path outdoors.
■■ Plan installation to use fewest number of elbows and turns. ■■ When using elbows or making turns, allow as much room
as possible.
■■ Bend vent gradually to avoid kinking. [. . . ] For complete details, see Installation Instructions packed with product. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WED4616FW
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL WED4616FW will begin.