User manual WHIRLPOOL HDD W40 S INSTRUCTION FOR USE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHIRLPOOL HDD W40 S. We hope that this WHIRLPOOL HDD W40 S user guide will be useful to you.


WHIRLPOOL HDD W40 S INSTRUCTION FOR USE: Download the complete user guide (7512 Ko)

Manual abstract: user guide WHIRLPOOL HDD W40 SINSTRUCTION FOR USE

Detailed instructions for use are in the User's Guide.

[. . . ] The power cable must be long enough for connecting the appliance, once fitted in its housing, to the power supply socket. The electrical components must not be accessible to the user after installation. Do not touch the appliance with any wet part of the body and do not operate it when barefoot. The appliance is not intended for use by persons (including children) with any physical, sensory or mental impairment, or without experience and knowledge of the appliance, unless supervised or previously instructed in its use by those responsible for their safety. [. . . ] WARNING: when the hob is in use, accessible parts of the hood may become hot. Installation and connection After unpacking the appliance, check for any transport damage. To prevent any damage, only remove the appliance from its polystyrene foam packaging at the time of installation. Preparing for installation WARNING: this is a heavy product; the hood should only be lifted and installed by two or more people. The minimum distance between the hob and the bottom part of the hood must not be less than 65 cm for gas cookers and 50cm for electric cookers. Before installation also check the minimum distances stated in the manual of the cooker. If the installation instructions for the cooker specify a greater distance between cooker and hood, this distance must be observed. Electrical connection Make sure the power voltage specified on the appliance rating plate is the same as the mains voltage. This information can be found on the inside of the hood, under the grease filter. Power cable replacement (type H05 VV-F) must be carried out by a qualified electrician. If the hood is fitted with an electric plug, connect the plug to a socket complying with current regulations, located in an accessible place. If no plug is fitted (direct wiring to the mains), or if the socket is not located in an accessible place, a qualified electrician should install a standardised double pole power switch that will enable complete ENGLISH 6 isolation from the mains in case of category III overvoltage conditions, in accordance with wiring rules. Use The hood has been designed to be installed and used either as a “Exhausted model”, or as a “Recirculation model”. Exhausted model (see symbol in installation booklet) Cooking steam is sucked and channelled outside the house through a discharge duct (not supplied), fitted to the hood steam outlet. Ensure that the discharge duct is correctly fitted to the air outlet, unit using an appropriate connection system. Recirculation model (see symbol in installation booklet) The air is filtered through one or more the charcoal filters, and then resent into room. Important: If the hood is supplied without charcoal filters, these must be ordered and fitted before the hood can be used. The hood should be installed away from particularly dirty areas, windows, doors and heat sources. The hood is sold with all necessary components for installation on most types of walls or ceilings. However, ask a qualified technician to check that the items supplied are suitable for the type of wall/ceiling. 2 4 3 4 5 Control panel A Light switch: move right to switch the light on. B Suction power selection switch: move right to switch on and to select the desired power/speed 0 1 0 1 2 3 A B Cleaning and maintenance WARNING: - Never use steam cleaning equipment. [. . . ] If your appliance still does not work properly after carrying out the checks listed in the troubleshooting guide and switching the appliance on again, contact the After-sales service, clearly explaining the problem and specifying: • the type of fault; • the model; • the type and serial number of the appliance (given on the rating plate); • the Service number (the number after the word SERVICE on the rating plate inside the appliance). ENGLISH 10 Technical data Dimensions (mm) Width Height Depth Airflow max - Exhaust (m /h) 3 800 min 990 - max 1540 480 572 67 320 72 200 2x 20W Noise max - Exhaust (dBa) Airflow max - Recirculating (m3/h) Noise max - Recirculating (dBa) Total Power (W) Lamps Installation minimun height dimensions (cm) gas or combi cookers electric cookers The technical information are situated in the rating plate on the internal side of the appliance and in the energy label. 65 50 ENGLISH 1 1 Disposal of packing The packing material is 100% recyclable and is marked with the recycle symbol . The various parts of the packing must therefore be disposed of responsibly and in full compliance with local authority regulations governing waste disposal. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL HDD W40 S




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL HDD W40 S will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.