[. . . ] - The appliance must be disconnected from the power supply before carrying out any installation work. - Installation and maintenance must be carried out by a qualified technician, in compliance with the manufacturer's instructions and local safety regulations. Do not repair or replace any part of the appliance unless specifically stated in the user manual.
TECHNICAL INFORMATION FOR THE INSTALLER
· · This product can be embedded in a worktop 20 to 60 mm thick. If there is no oven beneath the hob, insert a separator panel that has a surface at least equal to the opening in the work surface. [. . . ] Borghi, 27 21025 Comerio (VA) ITALY
ELECTRICAL CONNECTION WARNING WARNING
This operation must be performed by a qualified technician. · · · The electrical connections must comply with local regulations. L Earth (yellow/green) N
REPLACING THE INJECTORS (see the injector table in the Instruction)
· · · Remove grids (A). Using a socket spanner of the appropriate size unscrew the injector (C), unscrew the injector to be replaced. · Replace it with the injector suitable for the new type of gas. · If you have a multiple crown burner use side spanner to replace the injector (E). Before installing the hob, remember to affix the gas calibration plate supplied with the injectors in such a way that it covers the existing information relating to gas calibration.
IMPORTANT: the data relevant to the voltage and power absorption are indicated on the rating plate.
ASSEMBLY
After having cleaned the perimeter surface, apply the supplied gasket to the hob as shown in the figure.
ADJUSTING MINIMUM GAS SETTING OF TAPS
Position the hob in the worktop opening made respecting the dimensions indicated in the Instruction. NOTE: the power supply cable must be long enough to permit its upward extraction. Fit the brackets into the relevant bores shown by the arrow and fasten them by means of their screws in accordance with the thickness of the worktop (see the following figures). Top 20 mm
20 40
Top 40 mm
To ensure that the minimum setting is correctly adjusted, remove the knob and proceed as follows: · tighten screw to reduce the flame height (-); · loosen screw to increase the flame height (+). The adjustment must be performed with the tap in minimum gas setting position (small flame) . · At this stage, light up the burners and turn the knobs from max position to
minimum position to check flame stability. Upon completion of adjustment, reseal using sealing wax or an equivalent material.
Top 30 mm
30
Top 60 mm
REFERENCE TO LOCAL REGULATIONS
Provision for ventilation
60
ADJUSTMENT TO DIFFERENT TYPES OF GAS WARNING
This operation must be performed by a qualified technician.
The room in which the appliance is installed must have an air supply to current B. S. All rooms require a permanent vent in addition to the openable window. 5440 - Part 2 should be consulted to determine the air vent requirements. If the appliance is installed in a cellar or basement, it is advisable to provide an air vent of 65 cm, irrespective of the room volume.
Gas Safety Regulations
The law requires that all gas appliances are installed by competent persons in accordance with the current gas safety regulations. It is in your own interest, and that of safety, to ensure that the law is complied with. The hob should be installed in accordance with the Gas Safety (Installation and Use) Regulations, the Building Regulations issued by the Department of the Environment and the Building Standard (Scotland) (Consolidation) Regulations, issued by the Scottish Development Department. In the G. B. , CORGI registered installers work to safe standards of practice.
If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and information label on the top of the hob, change the injectors. Remove the information label and keep it with the instructions booklet. [. . . ] · To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting. · Press the knob against the control panel to ignite the burner. · After the burner has ignited, keep the knob pressed for about 5-10 seconds to allow proper device operation. This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden draught, an interruption in the gas delivery, boiling over of liquids, etc. ). [. . . ]