SERVICE MANUAL
SPLIT TYPE
RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E RAS-4M27GAV-E RAS-M10GKCVP-E, RAS-M13GKCVP-E, RAS-M16GKCVP-E RAS-4M27GACV-E RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E RAS-3M26GAV-E
Revised pages : 3 & 83
R410A
PRINTED IN JAPAN, May, 2006 ToMo
CONTENTS
1. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] However if temperature of the indoor heat exchanger becomes over 55°C or more in B room, the indoor fan stops the intermittent operation and starts continuous operation. While heating operation is executed in two rooms, if room temperature reached the setup temperature in both rooms and thermo-off occurred, both indoor units start intermittent operation of the indoor fan.
Indoor fan: Operates with setup number of revolution A room Thermo-ON continues 0 rpm B room thermo-OFF B room thermo-ON Thermo-OFF Thermo-ON 0 rpm B room thermo-ON Operated with setup number of revolution UL (1) Fan stop T on T off T on T off UL (1) Fan stop T on T off T on=2 min. UL (1) Fan stop 1 Operated with UL or SUL
In case which Tc sensor temperature exceeds 55°C in B room, the fan stops intermittent operation and starts continuous operation with UL or SUL (1).
71
10. Safety Cautions
For the rear left and left piping
Hook 47 mm or more 1 Installation plate Hook 140 mm or more 74 mm or more Hook Wall
Insert the cushion between the indoor unit and wall, and tilt the indoor unit for better installation work.
7 Mounting screw
Do not allow the drain hose to become slack.
Cut the piping hole slightly sloped 5 Zeolite-plus filter Z Shield pipe (for extension drain hose)
Make sure the drain hose is sloped downward.
6 Plasma pure filter
Air filters
Y
The auxiliary piping can be connected at the left, rear left, rear right, right, bottom right or bottom left as shown below.
2 Wireless remote controller 100 mm or more from wall
(C)
80 mm or more only when unobstructed to the front and both sides In principle, leave open 50 mm or more from wall
(D)
Right
Rear right
4 Remote controller holder (Mounting holes on both left and right sides) 200 mm or more
(B) (A)
Left Bottom left Bottom right Rear left
As shown in the figure, position power cord and connecting cable downward, and lead out along piping connection port.
8 Remote controller holder mounting screw 250 mm or more from wall When installing the outdoor unit, leave open in at least two of directions (A), (B), (C) and (D) shown in the right figure. Ensure sufficient space to allow drainage Power cord Extension drain hose (Option: RB-821SW)
Insulate the refrigerant pipes separately, not together.
6 mm thick heat resisting polyethylene foam
Before installing the wireless remote controller · With the remote controller cover removed, correctly load the supplied batteries while observing their polarity.
2 Wireless remote controller Cover 3 Batteries
72
10-2. Optional Installation Parts
Part Code Parts name Refrigerant piping Indoor unit name
Y
Q'ty
Liquid side (Outer diameter) 6. 35 mm 6. 35 mm
Gas side (Outer diameter) 1 ea. 9. 52 mm 12. 7 mm 1
RAS-B10GKVP-E, B13GKVP-E RAS-B16GKVP-E
Z
Shield pipe (for extension drain hose) (polyethylene foam, 6 mm thick)
10-2-2. Part name (Q'ty)
Installation plate × 1
Remote control holder × 1
Mounting screw Ø4 × 25L × 6
Wireless remote control × 1
Zeolite-plus filter × 1
Remote control holder mounting screw Ø3. 1 × 16L × 2
<Others>
Battery × 2
Plasma pure filter × 1
Name Owner's manual (Indoor unit) Installation manual (Indoor unit) Installation manual (Outdoor unit)
This model is not equipped with an extension drain hose.
Specifications (Outdoor unit)
73
10-2-3. Installation/Servicing Tools
Changes in the product and components In the case of an air conditioner using R410A, in order to prevent any other refrigerant from being charged accidentally, the service port diameter of the outdoor unit control valve (3-way valve) has been changed. (1/2 UNF 20 threads per inch) · In order to increase the pressure resisting strength of the refrigerant piping flare processing diameter and size of opposite side of flare nuts has been changed. (for copper pipes with nominal dimensions 1/2 and 5/8) New tools for R410A
New tools for R410A Applicable to R22 model Changes As pressure is high, it is impossible to measure by means of conventional gauge. In order to prevent any other refrigerant from being charged, each port diameter has been changed. In order to increase pressure resisting strength, hose materials and port size have been changed (to 1/2 UNF 20 threads per inch). As pressure is high and gasification speed is fast, it is difficult to read the indicated value by means of charging cylinder, as air bubbles occur. Incidentally, a common wrench is used for nominal diameters 1/4 and 3/8. By increasing the clamp bar's receiving hole, strength of spring in the tool has been improved.
Gauge manifold
× ×
¡
Charge hose
Electronic balance for refrigerant charging
Torque wrench (nominal diam. 1/2, 5/8)
×
¡
-- --
Flare tool (clutch type)
Gauge for projection adjustment
Used when flare is made by using conventional flare tool. It is necessary to use an adapter to prevent vacuum pump oil from flowing back to the charge hose. The charge hose connecting part has two ports-one for conventional refrigerant (7/16 UNF 20 threads per inch) and one for R410A. If the vacuum pump oil (mineral) mixes with R410A a sludge may occur and damage the equipment.
Vacuum pump adapter
¡
Gas leakage detector
×
Exclusive for HFC refrigerant.
· Incidentally, the "refrigerant cylinder" comes with the refrigerant designation (R410A) and protector coating in the U. · Also, the "charge port and packing for refrigerant cylinder" require 1/2 UNF 20 threads per inch corresponding to the charge hose's port size.
74
10-3. Installation Place
· A place which provides enough spaces around the indoor unit as shown in the diagram. [. . . ] 4306S709 4306S710 4306S711 43067115 Description P Board Ass'y . C. Outdoor Unit
4
41, 42 6 35 23 24 44 33 34 50 36
25 39, 40
43 32
52 12, 45, 47 13, 46, 48 15, 18, 21 14, 17, 20 16, 19, 22 49 27 30 50, 51 9 1 37 2
38
7
5 8
3
29 28 10 31
125