User manual TOSHIBA RAS-16UAV-E SERVICE MANUAL
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAS-16UAV-E. We hope that this TOSHIBA RAS-16UAV-E user guide will be useful to you.
Manual abstract: user guide TOSHIBA RAS-16UAV-ESERVICE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] SVM-04013
SERVICE MANUAL
AIR CONDITIONER
SPLIT WALL TYPE
RAS-13UKV-E3 / RAS-13UAV-E3 RAS-16UKV-E / RAS-16UAV-E
FILE NO. SPECIFICATIONS
1-1 1-2 1-3 Specifications Operation Characteristic Curve Capacity Variation Ratio According to Temperature Safety During Installation/Servicing Refrigerant Piping Installation Tools Recharging of Refrigerant Brazing of Pipes Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit (RAS-13UAV-E3) Outdoor Unit (RAS-16UAV-E) Indoor Unit Outdoor Unit (RAS-13UAV-E3) Outdoor Unit (RAS-16UAV-E) Refrigerant Cycle Diagram Operation Data Indoor Unit Outdoor Unit (Inverter Assembly) Outlined of Air Conditioner Control Description of Operation Circuit Temporary Operation Auto Restart Function Filter Check Lamp Remote Control and its Functions Hi POWER Mode ([Hi POWER] button on the remote control is pushed. ) Safety Cautions INDOOR UNIT OUTDOOR UNIT
2.
REFRIGERANT R410A
2-1 2-2 2-3 2-4. 2-5.
3.
CONSTRUCTION VIEWS
3-1 3-2
4.
WIRING DIAGRAM
4-1 4-2 4-3
5.
SPECIFICATION OF ELECTRICAL PARTS
5-1 5-2
6.
REFRIGERANT CYCLE DIAGRAM
6-1 6-2
7.
CONTROL BLOCK DIAGRAM
7-1 7-2
8.
OPERATION DESCRIPTION
8-1 8-2 8-3 8-4 8-5 8-6 8-7
9.
INSTALLATION PROCEDURE
9-1 9-2 9-3
- 1-
FILE NO. HOW TO DIAGNOSE THE TROUBLE
10-1 10-2 10-3 10-4 10-5 10-6 10-7 10-8 10-9 First Confirmation Primary Judgment Judgment by Flashing LED of Indoor Unit Self-Diagnosis by Remote Control (Check Code) Judgment of Trouble by Every Symptom Check Code 1C (Miswiring in indoor/outdoor units) and 1E How to Diagnose Trouble in Outdoor Unit How to Check Simply the Main Parts How to Simply Judge Whether Outdoor Fan Motor is Good or Bad
11. [. . . ] It is necessary to use an adapter to prevent vacuum pump oil from flowing back to the charge hose. The charge hose connecting part has two ports-one for conventional refrigerant (7/16 UNF 20 threads per inch) and one for R410A. If the vacuum pump oil (mineral) mixes with R410A a sludge may occur and damage the equipment. Exclusive for HFC refrigerant.
Gas leakage detector
Incidentally, the "refrigerant cylinder" comes with the refrigerant designation (R410A) and protector coating in the U. Also, the "charge port and packing for refrigerant cylinder" require 1/2 UNF 20 threads per inch corresponding to the charge hose's port size.
46
FILE NO. Cutting a hole and mounting installation plate
<Cutting a hole> A place which provides the spaces around the When installing the refrigerant pipes from the rear. A place that allows easy installation of the piping to the outdoor unit. The indoor unit shall be installed as top of the Pipe hole indoor unit comes to at least 2 m height. Also it must be avoided to put anything on the top of 65 mm the indoor unit.
CAUTION
Direct sunlight to the indoor unit's wireless receiver should be avoided. The microprocessor in the indoor unit should not be too close to RF noise sources. (For details, see the owner's manual. ) <Remote controller> A place where there are no obstacles such as a curtain that may block the signal from the indoor unit. Do not install the remote control in a place exposed to direct sunlight or close to a heating source, such as a stove. Keep the remote control at least 1 m apart from the nearest TV set or stereo equipment. (This is necessary to prevent image disturbances or noise interference. ) The location of the remote control should be determined as shown below.
(Side view) (Top view)
5
The center of the pipe hole is above the arrow.
100 mm
Fig. After determining the pipe hole position on the mounting plate (A), drill the pipe hole (65 mm) at a slight downward slant to the outdoor side. NOTE: When drilling a wall that contains a metal lath, wire lath or metal plate, be sure to use a pipe hole brim ring sold separately. <Mounting the installation plate> For installation of the indoor unit, use the paper pattern on the back.
Anchor bolt holes
62 82. 5
Hook
2 m or more from floor
170 85
Indoor unit
7m
Indoor unit 5
m
45
75
45
*7m
m
1
Pipe hole Hook Thread Weight Hook Pipe hole
Installation plate
Remote Reception control range
Reception range * : Axial distance
Remote control
Indoor unit
7 Mounting screw
Fig. SVM-04013
<When the installation plate is directly mounted on the wall> 1. Securely fit the installation plate onto the wall by screwing it in the upper and lower parts to hook up the indoor unit. To mount the installation plate on a concrete wall with anchor bolts, utilize the anchor bolt holes as illustrated in the above figure. The supply voltage must be the same as the rated voltage of the air conditioner. NOTE: Wire type : More than H07RN-F or 245 IEC66 (1. 0 mm2 or more)
CAUTION
When installing the installation plate with a mounting screw, do not use the anchor bolt hole. [. . . ] 2) Remove the front cabinet, and put it down so that fan guard side directs downward. 3) Remove the hooking claws by pushing minus screwdriver according to the arrow mark in the right figure, and remove the fan guard. Attachment 1) Insert claw of the fan guard in the hole of the front cabinet. Check that all the hooking claws are fixed to the specified positions.
Minus screwdriver Hooking claw
84
FILE NO. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-16UAV-E
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-16UAV-E will begin.