User manual THEBEN COMPACT OFFICE 24V LUX

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THEBEN COMPACT OFFICE 24V LUX. We hope that this THEBEN COMPACT OFFICE 24V LUX user guide will be useful to you.


THEBEN COMPACT OFFICE 24V LUX : Download the complete user guide (228 Ko)

You may also download the following manuals related to this product:

   THEBEN COMPACT OFFICE 24V LUX (428 ko)

Manual abstract: user guide THEBEN COMPACT OFFICE 24V LUX

Detailed instructions for use are in the User's Guide.

[. . . ] Designated use The presence detector is solely intended for the purpose contractually specified between the manufacturer and the user. Any other or extended use has to be regarded as not complying with the designated use. Zwei Relais (compact office 24V) beziehungsweise ein Relais (compact office 24V Lux) dienen als Schaltausgänge. [. . . ] the QuickSet plus service remote control for starting-up the system is optionally available. With the remote control all potentiometer values can be set from a distance. Deactivation of brightness measurement "on" Depending on the installation location, natural light intensity, furniture, reflection characteristics of the room and the furniture it may be necessary to correct the settings by 1-2 steps on the scale. In the range between 2 - 15min the switch-off delay varies according to its self-learning behavior. Light measurement: adaptive or fixed hysteresis · Fix : if the lighting is continuously overridden by a superordinate logic, the adaptive mode can be deactivated. In case of presence, the contact does not close before the set switch-on delay has elapsed. Room surveillance function; the contact closes only in case of distinct movements (effective protection against false alarms). Whenever the sensor module is plugged onto the power module or the unit is energised, the detector goes through 3 phases which are indicated by an LED. LED flashes every second, both contacts are closed (light and presence on) · In case of absence, both contacts open after 30sec. The service phase can be terminated earlier by actuating the clic user remote control. The outputs of a number of detectors can be connected in parallel circuit operation. This enables coverage of large and irregularly shaped rooms such as openplan offices, corridors, underground parkings e. The brightness threshold value and switch-off delay time must be adjusted individually for each detector. The user remote control clic can only be used subject to certain restrictions (see section 6). 1 detector: Group addresses freely selectable, see the user manual concerning the user remote control clic 2 detectors: Detector 1: group address A or C Detector 2: group address B or D clic: group addresses A+B or C+D The lighting is switched on or off using ON, OFF 3 or more detectors: The user remote control clic cannot be used Both contacts are closed for 30sec. In case of movement (LED on), both contacts close · In case of absence (LED off), both contacts open after 10sec. Recommended mounting height Maximum range Mixed light measurement Light measurement deactivated Switch-off delay time for light Short pulse Switch-off delay time for presence Switch-on delay time for presence Room surveillance Compact power 24V compact power 24V Lux Compact power 24V compact power 24V Lux Compact power 24V compact power 24V Lux 24V AC/DC ±20% potential free relay 24V2Aµ, 230V~2Aµ minimum 1V / 1mA maximum 50W / 460VA potential free relay 24V2Aµ, 230V~2Aµ Analogausgang 0-10V (nur compact power 24V Lux) Ausgangsspannung Lastwiderstand Mischlichtmessung Tiefe Durchmesser Montageplatte Klemmen Grösse UP-Dose Umgebungstemperatur Schutzart Artikelnummern compact office 24V komplett compact office 24V Lux komplett · Analog output 0-10V (compact power 24V Lux only) Output voltage Load resistor Mixed light measurement Depth Diameter Mounting plate Terminals Size of concealed housing (for flush-mounting) Ambient temperature Degree of protection 20 360 052 20 360 055 Article numbers compact office 24V complete compact office 24V Lux complete · sensor module compact office 24V · Power module compact power 24V · Power module compact power 24V Lux Surface frame for compact office Service remote control QuickSet plus User remote control clic 20 360 052 20 360 055 20 360 053 20 540 009 20 540 010 20 010 002 20 360 035 20 360 045 0-10V DC > 10k linear approx. 10 - 5000 Lux Profondeur Diamètre Plaque de montage Bornes Boîtier encastré Température ambiante Classe de protection Numéros d`articles compact office 24V complet compact office 24V Lux complet 40mm 48mm 70 x 70mm Vis max. [. . . ] Return In case of a warranty claim, please return the device including the delivery note and a brief description of the fault to your responsible specialised stockist. Industrial proprietary rights The design as well as the hardware and software of these devices are protected by copyright. Lighting does not switch on or switches off in case of presence and darkness Lux value setting is too low; Lighting was switched off manually with clic; Person is outside the detection range; Detection is disturbed by obstacle(s); Set switch-off delay setting is too short Lux value setting is too high; The lighting has been switched on manually with clic recently (wait for 30 min); Detector is in test mode Wait until the switch-off delay time has elapsed (selflearning effect); Disturbing heat sources within the detection range (heaters, incandescent lamp/halogen lamp, moving objects (e. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THEBEN COMPACT OFFICE 24V LUX




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THEBEN COMPACT OFFICE 24V LUX will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.