User manual SUPERMICRO MBD-X7SPA-HF-D525
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUPERMICRO MBD-X7SPA-HF-D525. We hope that this SUPERMICRO MBD-X7SPA-HF-D525 user guide will be useful to you.
Manual abstract: user guide SUPERMICRO MBD-X7SPA-HF-D525
Detailed instructions for use are in the User's Guide.
[. . . ] This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license. BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA. Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. [. . . ] Watch Dog must also be enabled in the BIOS.
Watch Dog Jumper Settings (JWD) Jumper Setting Pins 1-2 Pins 2-3 Open Definition Reset (default) NMI Disabled
Fan5 Fan6 Dedicated LAN (X8DT3/i-F/-LN4F only)
JPW2 P1-DIMM3A
JPW3
J6
KB/MOUSE
A. Clear CMOS
JPW1 Fan1
USB 0/1
P1-DIMM3B P1-DIMM2A P1-DIMM2B P1-DIMM1A P1-DIMM1B CPU2
B. Watch Dog Enable
COM1
Fan7/ CPU2 SP1
VGA
JLAN1
LAN1 LAN3
P2-DIMM1B P2-DIMM1A P2-DIMM2B P2-DIMM2A LE1 CPU1
JLAN2
LAN2 LAN4
JF1 Fan3 SI/O TPM Header LES2 LES1 (*X8DT3 Models only) SAS4~7 SAS0~3 J5 Floppy Fan4 LSI 1068E JSM2 (*X8DT3 Models only) JL1 JWD JPS1JPS2
Fan2
P2-DIMM3B P2-DIMM3A Slot6 PCI-E 2. 0x8 LAN SPEC
X8DT3/i Series Rev. 2. 01
CTRL
Slot5 PCI-E 2. 0x8 in x16
Intel 5520 North Bridge
Slot4 PCI-E 2. 0 x16 LAN CTRL (X8DT3/i-LN4F) Slot3 PCI 33 MHz BIOS JBT1 Slot2 PCI-E x4 JI2C1 JI2C2 Slot1 PCI 33MHz COM2 JPL1 JPL2
J28 J27
A
ICH10R South Bridge T-SGPIO2 T-SGPIO1 I-BUTTON JP7 I-SATA5 I-SATA3
BMC/VGA CTRL
Battery
JP3
JPB USB6/7 USB4/5 JPG1 JUSB3 JUSB2
USB3
USB2 I-SATA4 I-SATA2 I-SATA0
2-30
JWOL
I-SATA1 JWF1
B
JSM1
D1
JD1 1 1 1
Fan8/ CPU1 FAN
JOH1
Chapter 2: Installation I2C Bus to PCI-Exp. Slots Jumpers JI2C1 and JI2C2 allow you to connect the System Management Bus (I2C) to PCI-Express slots. See the table on the right for jumper settings.
I2C to PCI-Exp Jumper Settings Jumper Setting 1-2 2-3 Definition Enabled Disabled (Default)
VGA Enable Jumper JPG1 allows the user to enable the onboard VGA connector. See the table on the right for jumper settings.
VGA Enable Jumper Settings Jumper Setting 1-2 2-3 Definition Enabled (Default) Disabled
J6
KB/MOUSE Fan5 Fan6 Dedicated LAN (X8DT3/i-F/-LN4F only) JPW2 P1-DIMM3A JPW3
A. VGA Enable
Fan7/ CPU2 SP1
VGA
COM1
JLAN1
LAN1 LAN3
P2-DIMM1B P2-DIMM1A P2-DIMM2B P2-DIMM2A LE1 CPU1
JLAN2
LAN2 LAN4
JF1 Fan3 SI/O TPM Header LES2 LES1 (*X8DT3 Models only) SAS4~7 SAS0~3 J5 Floppy Fan4 LSI 1068E JSM2 (*X8DT3 Models only) JSM1 JWOL JL1 JWD JPS1JPS2
Fan2 1 1 1
P2-DIMM3B P2-DIMM3A Slot6 PCI-E 2. 0x8 LAN SPEC
X8DT3/i Series Rev. 2. 01
CTRL
Slot5 PCI-E 2. 0x8 in x16
Intel 5520 North Bridge
Slot4 PCI-E 2. 0 x16 LAN CTRL (X8DT3/i-LN4F) Slot3 PCI 33 MHz BIOS JBT1 Slot2 PCI-E x4 BMC/VGA CTRL ICH10R South Bridge T-SGPIO2 T-SGPIO1 I-BUTTON JP7 I-SATA5 USB3 USB2 I-SATA4 I-SATA2 I-SATA0 I-SATA3 I-SATA1 JWF1
Battery
JI2C1 JI2C2
A
COM2 JPL1 JPL2
JP3
B
Slot1 PCI 33MHz
J28 J27
C
D1
JPB USB6/7 USB4/5 JPG1 JUSB3 JUSB2
2-31
JD1
Fan8/ CPU1 FAN
JOH1
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual SAS Enable/Disable (X8DT3/ X8DT3-F/X8DT3-LN4F only) Jumper JPS1 allows you to enable or disable the onboard SAS connections. See the table on the right for jumper settings.
1-2 2-3
SAS Enable Jumper Settings Jumper Setting Definition
SAS Enabled (Default) SAS Disabled
SAS RAID Select (X8DT3/X8DT3-F/ X8DT3-LN4F only) Jumper JPS2 allows you to select RAID Configuration settings for the onboard SAS connections. Select Jumper Settings Jumper Setting Open Closed Definition
Integrated Target Mode (IT) Software RAID (SR) (Default)
Note: For more information on LSI SAS RAID configuration, please refer to the LSI MegaRAID User's Guide posted on our website @ http://www. A • single floppy disk drive ribbon cable has 34 wires and two connectors to A
provide for two floppy disk drives. The connector with twisted wires always connects to drive A, and the connector that does not have twisted wires always connects to drive B.
Floppy Drive Connector Pin Definitions Pin# 1 3 5 Definition Ground Ground Key Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Pin # 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 Definition FDHDIN Reserved FDEDIN Index Motor Enable Drive Select B Drive Select B Motor Enable DIR STEP Write Data Write Gate Track 00 Write Protect Read Data Side 1 Select Diskette
Floppy Connector The floppy connector is located next to the Super I/O chip on the motherboard. See the table on the right for pin definitions.
7 9 11 13 15 17 19 21 23 25 27 29 31 33
Fan5 Fan6 Dedicated LAN (X8DT3/i-F/-LN4F only)
JPW2 P1-DIMM3A
JPW3
J6
KB/MOUSE
JPW1 Fan1
A. Floppy
USB 0/1
P1-DIMM3B P1-DIMM2A P1-DIMM2B P1-DIMM1A P1-DIMM1B CPU2
COM1
Fan7/ CPU2 SP1
VGA
JLAN1
LAN1 LAN3
P2-DIMM1B P2-DIMM1A P2-DIMM2B P2-DIMM2A LE1 CPU1
JLAN2
LAN2 LAN4
JF1 Fan3
Fan2 1 1
P2-DIMM3B P2-DIMM3A Slot6 PCI-E 2. 0x8 LAN SPEC
X8DT3/i Series Rev. 2. 01
CTRL
Slot5 PCI-E 2. 0x8 in x16
Intel 5520 North Bridge SI/O Floppy
JD1 Slot4 PCI-E 2. 0 x16
Fan8/ CPU1 FAN
JOH1
A
1
LAN CTRL (X8DT3/i-LN4F) Slot3 PCI 33 MHz BIOS JBT1 Slot2 PCI-E x4 JI2C1 JI2C2 Slot1 PCI 33MHz COM2 JPL1 JPL2
J28 J27
TPM Header LES2 LES1 (*X8DT3 Models only) SAS4~7 SAS0~3 J5
BMC/VGA CTRL
ICH10R South Bridge T-SGPIO2 T-SGPIO1 I-BUTTON JP7 I-SATA5 I-SATA3
LSI 1068E (*X8DT3 Models only) I-SATA1 JWF1
JSM2
Battery
JSM1 JWOL
D1
JP3
JPB USB6/7 USB4/5 JPG1 JUSB3 JUSB2
USB3
USB2 JL1 JWD JPS1JPS2 I-SATA4 I-SATA2 I-SATA0
Fan4
2-37
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual Serial ATA Ports Six Serial ATA Ports (I-SATA0~I-SATA 5) are located at JS1~JS6 on the motherboard. These ports provide serial-link signal connections, which are faster than the connections of Parallel ATA. SAS Ports (X8DT3/X8DT3-F/ X8DT3-LN4F only) SAS Ports 0~3, 4~7, located at JSM1/ JSM2, provide Serial-Attached SCSI connections on the X8DT3/X8DT3-F/ X8DT3-LN4F. See the layout below for SAS port locations.
Pin# 1 2 3 4 5 6 7
Serial ATA Pin Definitions Definition Ground TX_P TX_N Ground RX_N RX_P Ground
Note 1: For more information on SATA HostRAID configuration, please refer to the Intel SATA HostRAID User's Guide posted on our website @ http://www. supermicro. com/support/manuals/. Note 2: For more information on LSI SAS RAID configuration, please refer to the LSI MegaRAID User's Guide posted on our website @ http:// www. supermicro. com/support/manuals/.
KB/MOUSE Fan5 Fan6 Dedicated LAN (X8DT3/i-F/-LN4F only) JPW2 P1-DIMM3A Fan1 P1-DIMM3B P1-DIMM2A P1-DIMM2B P1-DIMM1A P1-DIMM1B CPU2 JPW3
A. SAS 4~7 (X8DT3/-F/-LN4F only)
1
COM1
Fan7/ CPU2 SP1
VGA
JLAN1
LAN1 LAN3
P2-DIMM1B P2-DIMM1A P2-DIMM2B P2-DIMM2A P2-DIMM3B P2-DIMM3A Slot6 PCI-E 2. 0x8 SPEC LE1 CPU1
JLAN2
LAN2 LAN4
Fan3 Intel 5520 North Bridge SI/O Floppy TPM Header BIOS JBT1 LES2 LES1 (*X8DT3 Models only) SAS4~7 SAS0~3 J5 ICH10R South Bridge T-SGPIO2 T-SGPIO1 LSI JSM2 1068E I-BUTTON JP7
JF1
Fan2 1 1
LAN
X8DT3/i Series Rev. 2. 01
CTRL
Slot5 PCI-E 2. 0x8 in x16
Slot4 PCI-E 2. 0 x16 LAN CTRL (X8DT3/i-LN4F) Slot3 PCI 33 MHz
Slot2 PCI-E x4 JI2C1 JI2C2 Slot1 PCI 33MHz COM2 JPL1 JPL2
BMC/VGA CTRL
JD1
Fan8/ CPU1 FAN
JOH1
H
G
Fan4
Battery
F D
I-SATA3
J28 J27
JP3
JPB USB6/7 USB4/5 JPG1 JUSB3 JUSB2
USB3
USB2 JL1 JWD JPS1JPS2 I-SATA4 I-SATA2 I-SATA0
E C
A
2-38
JWOL
I-SATA5 D1
I-SATA1 JWF1
B
(*X8DT3 Models only)
JSM1
Chapter 3: Troubleshooting
Chapter 3 Troubleshooting
3-1 Troubleshooting Procedures
Use the following procedures to troubleshoot your system. [. . . ] Load Optimal Defaults To set this feature, select Load Optimal Defaults from the Exit menu and press <Enter>. Then, select OK to allow the AMI BIOS to automatically load Optimal Defaults to the BIOS Settings. The Optimal settings are designed for maximum system performance, but may not work best for all computer applications. Load Fail-Safe Defaults To set this feature, select Load Fail-Safe Defaults from the Exit menu and press <Enter>. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SUPERMICRO MBD-X7SPA-HF-D525
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUPERMICRO MBD-X7SPA-HF-D525 will begin.