User manual SIEMENS LB55564GB/01 INSTALLATION INSTRUCTIONS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SIEMENS LB55564GB/01. We hope that this SIEMENS LB55564GB/01 user guide will be useful to you.


SIEMENS LB55564GB/01 INSTALLATION INSTRUCTIONS: Download the complete user guide (1822 Ko)

Manual abstract: user guide SIEMENS LB55564GB/01INSTALLATION INSTRUCTIONS

Detailed instructions for use are in the User's Guide.

[. . . ] D When the extractor hood is operated in exhaust-air mode simultaneously with a different burner which also makes use of the same chimney (such as gas, oil or coal-fired heaters, continuous-flow heaters, hot-water boilers) care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion. 2 Before using the first time Important notes: The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. The appliance may be connected to the mains by a qualified technician only. The appliance is not intended for use by young children or infirmed persons without supervision. [. . . ] Renewing the fleece filter: Under normal operating conditions (1 to 2 hours per day), the fleece filter will require replacing after 8 to 10 weeks. Printed fleece filters must be renewed no later than when the coloured printing has started to fade. In so doing you will ensure that safety regulations are upheld and the extractor hood performs as effectively as possible. Disposing of the old fleece grease filter: Fleece grease filters do not contain any pollutants. They can be composted and disposed of as biodegradable waste. Operating controls on different models on off Light 1 0 2 P Intensive setting Fan settings Light P 3 2 1 Intensive setting Fan settings Note: The light can be switched on at any time, including when the vapour extractor tray has been pushed back into the hood. 4 Filters and maintenance Metal grease filter The filter mat is made of non-combustible metal. Caution: As it becomes more and more saturated with grease, the filter also becomes increasingly inflammable. Cleaning the metal filter: Under normal operating conditions (1 to 2 hours per day), the metal grease filter will require cleaning after 8 to 10 weeks. Important: Metal filters that are heavily saturated with grease should not be cleaned at the same time as any crockery, etc. If the filter mat is going to be cleaned by hand, soak it first of all in a hot detergent solution for several hours. Clean the filter with a brush, rinse it off thoroughly and allow it to drip dry. In so doing you will be ensuring that the extractor hood performs as effectively as possible. Note: Do not use alcohol (spirit) on plastic parts, otherwise the surface may become matt in appearance. Switch off the extractor hood and isolate by pulling out the mains plug or switching off the disconnector on the installation side. Switch off the extractor hood and isolate by pulling out the mains plug or switching off the disconnector on the installation side. Even for some time after the bulbs have been switched off there is still a risk of burns. Replace the halogen light bulb (conventional halogen bulb, 12 Volt, max. Note: If the light does not function, check that the bulbs have been inserted correctly. 9 Installation Instructions: Important information Old appliances are not worthless rubbish. Please contribute to a better environment by disposing of packaging materials in an environmentally-friendly manner. Please ask your dealer or inquire at your local authority about current means of disposal. The extractor hood can be used in exhaust air or circulating air mode. Minimum distance between electric hob and bottom edge of extractor hood: 650 mm. The extractor hood must not be installed over a solid fuel cooker ­ a potential fire hazard (e. g. [. . . ] 120 mm Ø extraction pipe Attach the exhaust-air pipe directly to the air-pipe connector. Recirculated air mode The air cleaned by an additional activated carbon filter is conveyed back into the room. In recirculated air mode the exhaust opening must be protected by a grille (see optional accessories on the last page) in order to prevent a mechanical or electrical hazard. 12 Electrical connection The extractor hood must be connected to a correctly installed earthed socket only. Attach the earthed socket as close to the appliance as possible and in an accessible position. If the earthed socket is no longer accessible following installation of the extractor hood, a disconnector must be provided on the installation side. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIEMENS LB55564GB/01




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SIEMENS LB55564GB/01 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.