User manual PANASONIC WHADC1216G6E5

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PANASONIC WHADC1216G6E5. We hope that this PANASONIC WHADC1216G6E5 user guide will be useful to you.


PANASONIC WHADC1216G6E5 : Download the complete user guide (3979 Ko)

You may also download the following manuals related to this product:

   PANASONIC WHADC1216G6E5 (3555 ko)
   PANASONIC WHADC1216G6E5 (3555 ko)
   PANASONIC WHADC1216G6E5 (3555 ko)
   PANASONIC WHADC1216G6E5 (3555 ko)
   PANASONIC WHADC1216G6E5 (3555 ko)
   PANASONIC WHADC1216G6E5 (3555 ko)
   PANASONIC WHADC1216G6E5 (3555 ko)

Manual abstract: user guide PANASONIC WHADC1216G6E5

Detailed instructions for use are in the User's Guide.

[. . . ] Before operating the system, read these operating instructions thoroughly and keep them for future reference. Table of contents Safety precautions ………………………………………… 3-5 To adjust initial settings …………………………………… 6-7 How to use ……………………………………………… 8-11 Cleaning instructions ……………………………………… 12 Troubleshooting ………………………………………… 13-14 Information ………………………………………………… 15 The illustrations in this manual are for explanation purposes only and may differ from the actual unit. Before use, make sure the system has been installed correctly by an authorised dealer according to the given instructions. €¢ Panasonic Air-to-Water is a split system, consisting of two units: indoor and outdoor units. [. . . ] a B 5 °C ~ 25 °C 5 °C ~ 25 °C 15 Dry Concrete During construction to dry the concrete under a preset temperature. Do not use this menu for any other purposes and in period other than during construction (Refer to Information page). –  Note: • The current day and time need to be set in cases below: - When the power is turned on for the first time. - A long time has elapsed since the power was turned on the last time. €¢ The current time that has been set will be the standard time for all the timer operations. Caution Indicator (Tank Temperature above 60 °C) *1 The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners. *2 Only displayed when COOL mode is unlocked (Means when COOL mode is available). Turn on or off the system Press When the system is ON, the operation LED is lit and the actual water outlet temperature and outdoor ambient temperature are shown on the display. AUTO • Depending on the preset outdoor temperature, the system selects HEAT or *1 COOL operation mode. AUTO • Depending on the preset outdoor + TANK temperature, the system selects HEAT + TANK or *1 COOL + TANK operation mode. HEAT • The outdoor unit provides heat to the indoor unit. User HEAT • The outdoor unit provides heat to the + TANK sanitary water tank and indoor unit. TANK • The outdoor unit provides heat to the sanitary water tank. 2 Press • Dry concrete (does not show during normal operation) • The Water Inlet Temperature • Tank Temperature • Compressor Running Frequency • Error History • Heat mode total power consumption (Up to 999 days) • *1 Cool mode total power consumption (Up to 999 days) • Tank mode total power consumption (Up to 999 days) • Press to exit the STATUS mode. *1, *2 COOL • The outdoor unit provides cooling to the + TANK indoor unit and heating to the sanitary water tank. –  Note: • Press or wait for 30 seconds to exit the SETTING mode. €¢ The set temperature will be saved in the system once confirmed. €¢ The SETTING mode cannot be activated when the SERVICE and STATUS indicators are ON. €¢ The system will shift the temperature within water outlet temperature range. User Holiday mode • By setting the day (s) in holiday mode, it promotes energy saving while you are on holiday, and enables the system to resume at the preset temperature after your holiday. • The system will resume operation automatically at 00:00 am after the holiday. [. . . ] Operation LED is not lit or nothing is displayed on the control panel. Force Heater Mode Button • If a malfunction occurs in the system, the backup heater may be used to heat up the water. €¢ In the Force Heater mode, no other operation can be used. It can be unlocked only by authorised installers or our authorised service partners. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC WHADC1216G6E5




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC WHADC1216G6E5 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.