User manual OREGON RMR500A

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OREGON RMR500A. We hope that this OREGON RMR500A user guide will be useful to you.


OREGON RMR500A : Download the complete user guide (1227 Ko)

You may also download the following manuals related to this product:

   OREGON RMR500A (1194 ko)

Manual abstract: user guide OREGON RMR500A

Detailed instructions for use are in the User's Guide.

[. . . ] Temperature/humidity display for THGR122N remote sensor 2 RMR500 IM EN R8. indd 2 11. Calendar display (or temperature/humidity display for optional sensor) 2/29/08 11:37:21 AM * This product is designed to display the temperature and humidity reading of THGN500 in the outdoor temperature/ humidity area only. OUTDOOR SENSOR - THGN500 (FIG 4) 2 BACK VIEW (FIG 3) 1 4 3 1 1. 3. LED status indicator Wall mount hole Battery compartment RESET hole 2 4. 345 1. [. . . ] The sensor cannot be found. RMR500A: WWVB-60 signal: within 3200 km (2000 miles) of Fort Collins, Colorado. to enable or to disable clock signal TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results. CLOCK AND CALENDAR NOTE If optional sensors are installed: · · clock and calendar display will be replaced by temperature/humidity readings. to toggle between clock and temperature/ press humidity display, or calendar and temperature/humidity display; the display will return to temperature/humidity display after 1 minute. NOTE Reception takes 2-10 minutes. If the signal is weak, it can take up to 24 hours to get a valid signal. If signal reception is unsuccessful, place your unit next to a window, press and hold to force another signal search. 5 RMR500 IM EN R8. indd 5 2/29/08 11:37:29 AM EN EN Clock signal reception indicator: STRONG SIGNAL WEAK SIGNAL NO SIGNAL NOTE "HH. H" or "LL. L" will be displayed when the received temperature is out of the specified temperature range. MOLD ALERT This product features moisture alert function for the prevention of mold. If the humidity is over 60%, the mold MANUALLY SET CLOCK To set the clock manually, disable the clock signal reception first. Press and hold . will flash, and will stop flashing if the humidity alert icon is less than 60%. WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30-50 km (19-31 mile) radius with 75% accuracy. or to change the settings. The settings Press order is: time zone, 12/24 hr format, hour, minute, year, calendar mode (month ­ day / day ­ month), month and day. Press to confirm. Sunny Partially Cloudy Cloudy Rainy Snowy 3. RMR500: Time zone sets the clock +/- 23 hours from the received clock signal time. If you have deactivated the clock signal reception, do not set a value for time zone. RMR500A: Select the time zone: (0) Pacific, (+1) Mountain, (+2) Central or (+3) Eastern. BACKLIGHT TEMPERATURE AND HUMIDITY To toggle temperature unit: Press °C / °F. Press to activate LED backlight for 5 seconds. 6 2/29/08 11:37:33 AM RMR500 IM EN R8. indd 6 RESET Press RESET to return to the default settings. LxWxH Weight SPECIFICATIONS TYPE MAIN UNIT LxWxH Weight Signal frequency Temperature range Temperature resolution Humidity range Humidity resolution Power REMOTE UNIT (THGN500) LxWxH Weight Signal frequency Number of channel Transmission range Temperature range Temperature resolution DESCRIPTION 134 x 27 x 134 mm (5. 3 x 1. 1 x 5. 3 in) 300 g (10. 58 oz) without battery 433 MHz -5°C to 50°C (23°F to 122°F) 0. 1°C (0. 2°F) 25% - 95% 1% 4 x UM-4 (AAA) 1. 5 V batteries 50 x 22 x 96 mm (1. 9 x 0. 9 x 3. 8 in) 63 g (2. 22 oz) without battery 433 MHz 1 30 m (100 ft) unobstructed -20°C to 60°C (-4°F to 140°F) 0. 1°C (0. 2°F) Signal frequency Number of channel Transmission range Temperature range Temperature resolution Humidity range Humidity resolution Power 92 x 60 x 20 mm (3. 6 x 2. 4 x 0. 79 in) 63 g (2. 22 oz) without battery 433 MHz 3 30 m (100 ft) unobstructed -20°C to 60°C (-4°F to 140°F) 0. 1°C (0. 2°F) 25% - 95% 1% 2 x UM-4 (AAA) 1. 5 V battery PRECAUTIONS · · · · · · · Do not subject the unit to excessive force, shock, dust, temperature or humidity. Do not cover the ventilation holes with any items such as newspapers, curtains etc. If you spill liquid over it, dry it immediately with a soft, lint-free cloth. [. . . ] Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING Changes or modifications not expressly 8 RMR500 IM EN R8. indd 8 2/29/08 11:37:34 AM approved by the party responsible for compliance could void the user's authority to operate the equipment. support or sales. Please call our customer service number (listed on our website at www. oregonscientific. com, or on the warranty card for this product) for all inquiries instead. 19861 SW 95th Ave. , Tualatin, Oregon 97062 USA 1-800-853-8883 NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OREGON RMR500A




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OREGON RMR500A will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.