User manual LG ARWN200LA2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LG ARWN200LA2. We hope that this LG ARWN200LA2 user guide will be useful to you.


LG ARWN200LA2 : Download the complete user guide (797 Ko)

You may also download the following manuals related to this product:

   LG ARWN200LA2 (1142 ko)

Manual abstract: user guide LG ARWN200LA2

Detailed instructions for use are in the User's Guide.

[. . . ] · Do not charge the unit with refrigerant other than the refrigerant specified on the unit during the installation or transportation of the unit. · Do not change the settings of the safety equipment after the unit is installed. · Ventilate the room before operating the unit when there is a gas leak. [. . . ] · Ensure that the installation area is not deteriorated in time. OPERATION · Do not make modifications or extensions to power cord. · Do not store or use flammable material or gases in the vicinity of the unit. · Do not put your hand inside the air inlet or outlet during installation of the unit. · Do not put your hand or other things inside the air inlet or outlet during the operation of the unit. 4 | EN 2 Technical specification ENGLISH ARWN100LA2 Cooling Capacity Heating Capacity Input Power supply Running Current COP Noise level Dimensions (WxHxD) Net Weight Circuit Breaker Cooling Heating Cooling Heating kW kW kW kW Ø/V/Hz A _ _ dB(A) mm kg A 28. 0 31. 5 5. 6 5. 8 3/380 - 415/50 2. 5 ~ 20. 2 5. 0 5. 43 51 772x1, 120x547 163 30 ARWN200LA2 56. 0 63. 0 11. 2 11. 7 3/380 - 415/50 2. 5 ~ 31. 8 5. 0 5. 38 51 772x1, 120x547 223 40 ARWB100LA2 28. 0 31. 5 5. 6 5. 8 3/380 - 415/50 2. 5 ~ 20. 2 5. 0 5. 43 51 772x1, 120x547 163 30 ARWB200LA2 56. 0 63. 0 11. 2 11. 7 3/380 - 415/50 2. 5 ~ 31. 8 5. 0 5. 38 51 772x1, 120x547 223 40 Notes: 1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 20°C[68°F] * Interconnecting Piping Length 7. 5m (25 ft. ) * Level Difference of Zero 2. Due to our policy of innovation some specifications may be changed without notification 4. Add an anti freeze to circulation water when outside units is operating under 10°C(50°F), and change the DIP switch on main PCB. n Dip switch setting * Use this mode when temperature of circulation inlet water is under 10°C, You should use an anti freeze 5 | EN 3 Practical and Useful Information Do not overcool your room. This may cause health issues, and also it causes excessive power consumption. Keep all doors and windows closed whenever possible to keep the cool air inside the room. Prevent direct sunlight entering the room and keep the blinds and curtains closed when the air conditioner is operated. Clean the air filters regularly. Blockage in the air filter decreases air flow, cooling and dehumidification. If you do not clean air filters regularly, cooling capacity will be lowered and some of the energy you use will be wasted. Ensure that the room temperature and air flow is distributed homogeneously inside the room by adjusting the directions of the vertical and horizontal flaps of your air conditioner. Ventilate the room by opening the windows as possible, since the windows are kept closed during the operation of your air conditioner. Using air curtains on wide and large areas that the doors are kept open all the time, for example in cafeterias, patisseries etc. , will allow using your air conditioner more efficiently by reducing the electric consumption. Then, the room shall reach the desired temperature more quickly. If you will not use air conditioner for a long time, operate it in the fan position for 2 to 3 hours; this will remove the humidity inside the air conditioner. Then turn the A/C off with the fuse. 6 | EN 4 Consumer Services Dear Customers, ENGLISH Bosch Termoteknik Call Center operates 24/7 with the following telephone number: 444 9 474 (Automatic recording system is used between 20:00 and 09:00). You will be contacted in the next working hour when you call anytime other than the hours specified above and leave your name, surname and telephone number with the area code. [. . . ] Cleaning of the heat exchanger elements on the inner and outer units of the air conditioner is very important. When the heat exchanger elements get dirty, your air conditioner will operate more to provide the required cooing/heating, thus your energy consumption will be increased. Therefore, we advise you to have your air conditioner maintained at least once a year. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG ARWN200LA2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LG ARWN200LA2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.