User manual ICOM IC-F410

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-F410. We hope that this ICOM IC-F410 user guide will be useful to you.


ICOM IC-F410 : Download the complete user guide (1360 Ko)

You may also download the following manuals related to this product:

   ICOM IC-F410 BROCHURE (449 ko)
   ICOM IC-F410 BROCHURE (234 ko)
   ICOM IC-F410 Instruction Manual (233 ko)

Manual abstract: user guide ICOM IC-F410

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL VHF TRANSCEIVER iF310 iF320 UHF TRANSCEIVER iF410 iF420 This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. IMPORTANT READ ALL INSTRUCTIONS carefully and completely before using the transceiver. CAUTIONS RWARNING!This may pose a fire hazard or result in an electric shock. SAVE THIS INSTRUCTION MANUAL -- This instruction manual contains important operating instructions for the IC-F310, IC-F320, IC-F410 and IC-F420 VHF/UHF TRANSCEIVERS. NEVER connect the transceiver to a power source of more than 16 V DC such as a 24 V battery. This connection will ruin the transceiver. NEVER cut the DC power cable between the DC plug and EXPLICIT DEFINITIONS DEFINITION Personal injury, fire hazard or electric shock RWARNING may occur. [. . . ] · Push the key to toggle the mute and unmute conditions (toggles `Audible' and `Inaudible'). · Push the key to mute the channel (sets to `Inaudible' only). · Push the key to unmute the channel (sets to `Audible' only). · Push the key after the communication is finished to send a `reset code'. 1 LOCK HIGH LOW1 OUTPUT POWER SELECTION KEYS Select the transmit output power temporarily or permanently depending on the pre-setting. level for each selection. LOW2 · Ask your Dealer or System Operator for the output power MONI TA TALK AROUND KEY Turns the talk around function ON and OFF. · The talk around function equalizes the transmit frequency to the receive frequency for mobile-to-mobile communication. CALL CAL A CAL B CALL KEYS Transmit a 5-tone call. · Call transmission is necessary before you call another station depending on your signaling system. · The [CAL A] and/or [CAL B] keys may be available when your system employs selective `Individual/Group' calls. Ask your System Operator which call is assigned to each key. NOTE: The unmute condition (`Audible' condition) may automatically return to the mute condition (`Inaudible` condition) after a specified period. W/N EMER EMERGENCY KEY Push and hold the key to transmit an emergency call. · If you want to cancel the emergency call, push (or push and hold) the key again before transmitting the call. · The emergency call is transmitted one time only or repeatedly until receiving a control code depending on the pre-setting. WIDE/NARROW KEY Push [W/N] to toggle bandwidth between wide or narrow. · This function is available for W/N versions only. 4 1 PANEL DESCRIPTION TX CODE KEY Select a transmit 5-tone code (station code) channel. · Push and hold to changes the contents of the station code using [ ]/[ ] keys. · Push to selects a TX 5-tone code channel using [ ]/[ ] keys after pushing this key. TX CODE CHANNEL UP/DOWN KEY Push to selects a TX code channel directory. · Push this key, then select the desired DTMF channel using the [ ]/[ ] keys. NOTE: DTMF channels 6 and 7 are used for ID code and emergency code respectively, depending on your system set up. Ask your System Operator or Dealer about DTMF channels 6 and 7 before using these. GRP TX CH ID MR ID MEMORY READ KEY Recalls detected ID codes. ON: Low (0 V) OFF: High (12 V) ATTENUATOR Push to turn the attenuator function ON/OFF. NOTE: The attenuator function protects desired signals from distorting when excessively strong signals, such as broadcast, pager signals, etc. TRUNKING GROUP SWITCH Push to select the Trunking group. LITE CODE DTMF ATT TONE C. TONE CHANNEL ENTER KEY Push this key then input a continuous tone memory channel number via the keypad to change the tone frequency. 5 OPERATION I Turning power ON I q Push [K ] to turn the power ON. 2 I Channel selection Several types are available, and the channel selection method may differ according to your system set up. Opening message may differ depending on the pre-setting. · A power-up alert tone sounds for about 1 sec. and an opening message may appear. w If the transceiver is programmed for a start up passcode, input digit codes as directed by your System operator. Input your password if this display appears. NON-BANK TYPE: Push the [ ]/[ ] keys to select the desired operating channel, in sequence; or, push one of the [CH 1] to [CH 4] keys to select these channels directly. BANK-TYPE: Push [BANK] to select the desired bank number. · The keys in the diagram below can be used for password input: · The transceiver detects numbers in the same block as identical. When the Tx code channel number (or name) is displayed, the [ ]/[ ] keys select the Tx code channel. r Push [TX CH] again to return to the channel display. 2 D DTMF transmission If the transceiver has a [DTMF] key, the automatic DTMF transmission function is available. [. . . ] input power: 5 W UT-105 SmarTrunk IITM Logic Board Provides SmarTrunk IITM capabilities. HM-100T/TA DTMF microphone. OPC-617 ACC CABLE Allows you to connect to an external terminal. HM-100 Normal microphone. 16 A-5458D-1EX-e Printed in Japan © 1997 by Icom Inc. 1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003 Japan DECLARATION OF CONFORMITY We Icom Inc. Japan 1-1-32, Kamiminami, Hirano-ku Osaka 547-0003, Japan Declare on our sole responsibility that this equipment complies the essential requirements of the Radio and Telecommunications Terminal Equipment Directive, 1999/5/EC, and that any applicable Essential Test Suite measurements have been performed. Kind of equipment: Type-designation: VHF TRANSCEIVER 0168 Düsseldorf 07 Feb. 2001 Place and date of issue iC- f310/s 146­174 MHz 12. 5 KHz/ 20 KHz/ 25 KHz Icom (Europe) GmbH Himmelgeister straße 100 D-40225 Düsseldorf Authorized representative name Version (where applicable): This compliance is based on conformity with the following harmonised standards, specifications or documents: i) EN300 279 v1. 2. 1(1999-02) (EMC product standard) ii) EN60950 August 1992, A11 1997 (Safety of information technology equipment) iii) ETS300 086 January 1991 (Radio equipment for analog speech) iv) I-ETS300 219 October 1993 (Radio equipment transmitting signals) v) Icom (Europe) GmbH T. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-F410




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-F410 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.