User manual ICOM IC-E208

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-E208. We hope that this ICOM IC-E208 user guide will be useful to you.


ICOM IC-E208 : Download the complete user guide (3293 Ko)

You may also download the following manuals related to this product:

   ICOM IC-E208 BROCHURE (209 ko)
   ICOM IC-E208 BROCHURE (310 ko)

Manual abstract: user guide ICOM IC-E208

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL VHF/UHF FM TRANSCEIVER iE208 FOREWORD Thank you for purchasing this Icom product. The IC-E208 VHF/UHF FM TRANSCEIVER is designed and built with Icom's state of the art technology and craftsmanship. With proper care, this product should provide you with years of trouble-free operation. We want to take a couple of moments of your time to thank you for making your IC-E208 your radio of choice, and hope you agree with Icom's philosophy of "technology first. " Many hours of research and development went into the design of your IC-E208. IMPORTANT READ ALL INSTRUCTIONS carefully and completely before using the transceiver. SAVE THIS INSTRUCTION MANUAL-- This instruction manual contains important operating instructions for the IC-E208. EXPLICIT DEFINITIONS DEFINITION Personal injury, fire hazard or electric shock R WARNING! [. . . ] "M" and "#" can be used for "A" and "b" respectively. [M/CALL·PRIO] "!" appears w Rotate [DIAL] to select the desired memory channel. · Programmed memory channels only can be selected. 25 MEMORY OPERATION 5 I Programming a memory channel VFO settings, including the set mode contents such as subaudible tone frequency or offset, can be programmed into a memory channel. w Push [S. MW·MW]. · "!" indicator and the memory channel number blink. eRotate [DIAL] to select the memory channel to be programmed. · Memory channels not yet programmed are blank. r Push [S. MW·MW] for 1 sec. to program. · 3 beeps sound · Memory channel number automatically increases when continuing to push [M/CALL·MW] after programming. 5 CONVENIENT Memory programming can be performed in versatile ways e. g. memory channel to the same (or different) memory channel, memory channel to the call channel, etc. [EXAMPLE]: Programming 145. 870 MHz into memory channel 20 (blank channel) via the controller. Push Rotate for setting frequency, etc. and continue to push " "Beep " Beep " Beep " "Beep 26 5 MEMORY OPERATION D Programming a memory channel via the microphone The microphone can also be used to program memMW ory channels. z Set the desired frequency in VFO mode. offset frequency, duplex direction, subaudible tone encoder ON/OFF and its frequency), if necessary. · Direct numeral input cannot be used. v Push [FUNC] then [CLR A(MW)] for 1 sec. 3 beeps may sound and the VFO contents (including the subaudible tone frequency, etc. ) are programmed. Memory channel number increases when continuing to push [CLR A(MW)] after programming. [EXAMPLE]: Programming 145. 870 MHz into memory channel 20 (blank channel) via the microphone. Push Push then "Beep Push 10 times Push then for 1 sec. and continue to push " "Beep " Beep " Beep " 27 "Beep MEMORY OPERATION 5 I Copying memory contents This function copies a memory channel's contents to VFO (or another memory/call channel). This is useful when searching for signals around a memory channel frequency and for recalling the offset frequency, subaudible tone frequency etc. D Memory/callVFO q Select the desired memory or call channel. Push [M/CALL·PRIO] several times to select memory mode or call channel, then rotate [DIAL] or push [BAND] to select the desired memory or call channel respectively. to transfer the selected memory/call channel contents to the VFO. · VFO mode is selected automatically. MR/CALL MW [Y]/[Z] BAND z Select the memory/call channel to be transferred. Push [MR/CALL] to select memory mode, then select the desired memory channel via [Y]/[Z] or keypad. to transfer the selected memory/call channel contents to the VFO. · VFO mode is selected automatically. 5 [EXAMPLE]: Transferring memory channel 30 contents to VFO. Front panel operation: Push to select memory mode. Rotate for selecting memory channel. Push for 1 sec. HM-133 operation: Push to select memory mode. Push [Y]/[Z] to select memory channel. Push then push for 1 sec. 28 5 MEMORY OPERATION z Select the memory/call channel to be transferred. Push [MR/CALL] to select memory mode, then select the desired memory channel via [Y]/[Z] or keypad. x Push [FUNC], then [CLR A(MW)] momentarily. · "!" indicator and "-- -- --" indication blink, and shows VFO conditions. D Memory/callmemory/call q Select the memory/call channel to be transferred. Push [M/CALL·PRIO] several times to select memory mode or call channel, then rotate [DIAL] or push [BAND] to select the desired memory or call channel respectively. w Push [S. MW·MW] momentarily. · "!" indicator and "-- -- --" indication blink, and shows VFO conditions. MR/CALL MW [Y]/[Z] e Rotate [DIAL] to select the target memory channel. · "C1" or "C2" blinks when the call channel is selected. · Scan edge channels, 1A/1B, 2A/2B, 3A/3B, 4A/4B, 5A/5B can also be selected. BAND c Push [Y]/[Z] to select the target memory channel. · "C1" or "C2" blinks when the call channel is selected. · The keypad cannot be used for the selection. r Push [S. MW·MW] for 1 sec. [. . . ] 46 70 12 MAINTENANCE PROBLEM POSSIBLE CAUSE SOLUTION REF. -- Some memory channels · The memory channel number has not yet been · Select the channel via the microphone keypad to cannot be selected via the programmed. 15 · Only 1 memory channel is programmed or other · Program other memory channels or cancel the pgs. 65 I Fuse replacement If the fuse blows or the transceiver stops functioning, find the source of the problem if possible, and replace the damaged fuse with a new, rated one (FGB 20 A) as shown at right. 20 A fuse 71 SPECIFICATIONS AND OPTIONS I Specifications D GENERAL · Frequency coverage Europe : Rx 118. 000­173. 995 MHz*1, 230. 000­549. 995 MHz*2, 810. 000­999. 990 MHz 144­146 MHz, 430­440 MHz 118. 000­173. 995 MHz*1, 230. 000­549. 995 MHz*2, 810. 000­999. 990 MHz 144­146 MHz, 430­434 MHz, 435­438 MHz 144­146 MHz, 430­440 MHz 13 D TRANSMITTER · Modulation system · Output power · Max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-E208




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-E208 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.