User manual ICOM IC-2800H

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-2800H. We hope that this ICOM IC-2800H user guide will be useful to you.


ICOM IC-2800H : Download the complete user guide (996 Ko)

You may also download the following manuals related to this product:

   ICOM IC-2800H BROCHURE (399 ko)
   ICOM IC-2800H BROCHURE (361 ko)
   ICOM IC-2800H INSTRUCTION MANUAL (970 ko)

Manual abstract: user guide ICOM IC-2800H

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL DUAL BAND FM TRANSCEIVER i2800H This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FOREWORD READ ALL INSTRUCTIONS carefully and completely before using the transceiver. CAUTIONS RWARNING!This may pose a fire hazard or result in an electric shock. SAVE THIS INSTRUCTION MANUAL -- This instruction manual contains important operating instructions for the IC-2800H. RWARNING!Safe driving requires your full attention--anything less may result in an accident. [. . . ] when you want to find a subaudible tone frequency necessary to open a repeater). 53 for details. s Scan types Scanning searches for signals automatically and makes it easier to locate new stations for contact or listening purposes. There are 3 scan types and 4 resume conditions to suit your operating needs. Used as the simplest scan without any preliminary settings necessary. PROGRAMMED SCAN (p. 43) Band edge Scan edges Band edge Band edge Scan Jump Band edge Scan Jump Repeatedly scans between two user-programmed frequencies. Used for checking for frequencies within a specified range such as repeater output frequencies, etc. 45) Not yet programmed ch 1 ch 99 ch 98 ch 6 ch 5 ch 2 ch 3 ch 4 (skip) Repeatedly scans memory channels except those set as skip channels. Used to search through often-used memories and for bypassing normally busy channels such as repeater frequencies. SCAN RESUME CONDITION (p. 46) Receiving a signal Pause scan Timer scan Pausing 2 sec. 4 resume conditions are available: 3 timer scans and pause scan. When receiving a signal, pause scan pauses until the signal disappears; timer scans pause for 5, 10 or 15 sec. 42 SCAN OPERATION 9 s Full/programmed scan q Select VFO mode with the desired band's [V/MH]. · Push [CHG/L] if [V/MH] is not displayed. y To stop the scan, push [PRO] again. If the same frequencies are programmed into a pair of scan edges, programmed scan does not start. to enter scan screen. · If the pocket beep function is activated, the transceiver automatically selects the tone squelch function when the scan screen is selected. MAIN í MAIN M-L 145. 320 12 MAIN SCP V/MH TS M/C SCN MONI SCAN PRO P1 1 4 PRIO Resume 4 . 8 Pause TON SEL Res 43 3. 000 YZ MID-LO 12 LOW r Push [SEL] one or more times to select the desired scan edges, if necessary. 44 for details. · "AL" for full scan, "AA" for air band scan (U. S. A. America versions only), "A1"/"A4" for 144 MHz/430(440) MHz band scan or "P1"­"P3" for programmed scan. · Only programmed scan edges can be selected. q Select the desired band with [BAND]. r Select the desired scan edges using the controller unit, if necessary. 44 for details. · "AL" for full scan, "AA" for air band scan (U. S. A. America versions only), "A1"/"A4" for 144 MHz/ 430(440) MHz band scan or "P1"­"P3" for programmed scan. · Only programmed scan edges can be selected. t Push [PRO] momentarily to start the scan. · Decimal point flashes while scanning. · "AL, " "AA"/"A1"/"A4" or "P1"­ "P3" flashes to indicate full scan, band scan or programmed scan edges, respectively. · To change the scanning direction, rotate the desired band's tuning dial. [. . . ] Enter `Opening Title' and clone `Comment. ' MIC Option : Switches on the transceiver's front panel can be assigned to the microphone's [F-1]/[F-2] for the HM-98 and [UP]/[DN] for the HM-97 and HM-118/T/TA. Display s Exiting cloning mode ¯ After cloning is finished, push the [UP]/[DN] or [Y]/[Z] on the microphone to exit the cloning mode and to return to normal operating condition. · The [POWER] switch does not function in the cloning mode. There are 3 setting menus available. Common : Commonly set items such as operation beeps, sub band mute, sub band beep, RF attenuator, name display, TOT, auto repeater, auto power-off, cooling fan setting, packet data speed, squelch delay, VHF/UHF scan resume timer and RF output power settings. DO NOT disconnect the controller cable while in the cloning mode. The transceiver remains in the cloning mode and continues in power ON condition. 79 17 TROUBLESHOOTING If your transceiver seems to be malfunctioning, please check the following points before sending it to a service center. PROBLEM No power comes on. · A selective call or squelch function is activated · Turn the appropriate function OFF. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-2800H




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-2800H will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.