User manual GRASS VALLEY JUPITER CM-4400 VERSION 7.9.0 - 10-2010

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GRASS VALLEY JUPITER CM-4400. We hope that this GRASS VALLEY JUPITER CM-4400 user guide will be useful to you.


GRASS VALLEY JUPITER CM-4400 VERSION 7.9.0 - 10-2010: Download the complete user guide (10034 Ko)

Manual abstract: user guide GRASS VALLEY JUPITER CM-4400VERSION 7.9.0 - 10-2010

Detailed instructions for use are in the User's Guide.

[. . . ] JUPITER CM-4400: AccuSwitch Control System Installation and Operating Manual Software Version 7. 9. 0 071876600 OCTOBER 2010 Affiliate with the N. V. KEMA in The Netherlands CERTIFICATE Certificate Number: 510040. 001 The Quality System of: Thomson Inc, and it's wordwide Grass Valley division affiliates DBA GRASS VALLEY Headquarters 400 Providence Mine Rd Nevada City, CA 95959 United States Kapittelweg 10 4827 HG Breda The Nederlands Rue du Clos Courtel CS 31719 35517 Cesson-Sevigné Cedex France 40 Rue de Bray 2 Rue des Landelles 35510 Cesson Sevigné France Carl-Benz-Strasse 6-8 67105 Schifferstadt Germany 15655 SW Greystone Ct. Beaverton, OR 97006 United States 7140 Baymeadows Way Ste 101 Jacksonville, FL 32256 United States 1 rue de l'Hautil Z. I. des Boutries BP 150 78702 Conflans-Sainte Honorine Cedex France Spinnereistrasse 5 CH-5300 Turgi Switzerland 10 Presidential Way Suite 300 Woburn, MA 01801 United States 2300 So. [. . . ] Click on the preferred switcher input table name and "OK. " This will bring up a table similar to that shown in Figure 112 on page 163. If the table is based on the factory-supplied Numeric set, the table illustrates the reason for the name "numeric"- the Name column shows all the inputs with numbers instead of names. 3. Enter/edit the preferred logical name and physical input numbers for the inputs. Note Only physical inputs 000-999 can be used as Primary and Indirect sources 164 JUPITER CM-4400 Control Module Installation and Operating Manual Switcher Input Table 4. Add new inputs at the end of the tables. Row numbers on Jupiter tables are used as the logical numbers for sources. Changing the row number of an existing source (by inserting/ deleting a new input in the middle of the table, for example) will disrupt control of the system. The memory on the controller boards will need to be cleared and reset (see Clearing Persistent Memory (PMEM) on page 106). Adding new inputs at the end of tables will help to avoid this interruption. 5. Save your changes, validate, compile, and activate the configuration set. Data Switching Applications In Venus DM 400B data switching applications, the switcher input table is used to assign a logical name to each physical port connected to a "tributary" device. See Figure 115 for an example and the Switcher Input table settings. Figure 115. Example of DM 400B System. Controller Tributary Editor selected as switcher OUTPUT Port 00 Port 01 VTR 1 selected as switcher INPUT 071826105_DM400B system Example DM 400B Data Matrix Tributary Port 02 VTR 2 selected as switcher INPUT Switcher Input - MAINROUT Logical Input VIDEO Name 1 2 3 4 SAFE EDIT1 VT01 VT02 000 001 002 000 001 002 000 001 002 000 001 002 LEFT RIGHT TC DATA 064 000 001 002 Similarly, the switcher output table is used to assign a logical name to each physical port connected to a "controller" device. Note All port numbers that reside in the Switcher Output table must also have an entry in the Switcher Input table (This is done to avoid possible Status display problems and is checked by the PC compiler). JUPITER CM-4400 Control Module Installation and Operating Manual 165 Section 5 -- The Configurator Application Figure 116. Output Switcher Table for DM400B 826105_Switcher-Output for DM4 Switcher Output - MAINROUT Logical Output Security Name 1 2 EDIT1 - - S-T Pass word VIDEO 000 LEFT 000 RIGHT 000 TC 000 DATA 000 Controller / Tributary Reassignment Some VTRs can themselves act as controllers or tributaries. With the DM 400B the associated ports can be configured as both inputs and outputs; this allows their pinouts to adjust automatically depending on which VTR is selected as the output (controller) and which is selected as the input (tributary). In Figure 117, VTR 1 is the controlling device; accordingly it is selected as a switcher output in order to configure the switcher port correctly. Controller-Tributary Reassignment Controller pinout Port 01 Tributary pinout DM 400B Data Matrix Tributary pinout VTR 1 selected as switcher OUTPUT 071826105_Controller-Tributary Reassignment Port 02 Controller pinout VTR 2 selected as switcher INPUT In Figure 118, the roles are reversed. The switcher ports are configured properly by selecting VTR 2 as an output and VTR 1 as an input. 166 JUPITER CM-4400 Control Module Installation and Operating Manual Switcher Input Table Figure 118. Controller-Tributary Reassignment- Reversed Tributary pinout Port 01 Controller pinout DM 400B Data Matrix Controller pinout VTR 1 selected as switcher INPUT 071826105_Controller-Tributary Reassignment-Reversed Port 02 Tributary pinout VTR 2 selected as switcher OUTPUT Examples of Switcher Input and Switcher Output tables for this reassignment application are shown in Figure 119. Figure 119. Switcher Input and Output Tables for Controller / Tributary Reassignment Switcher Input - MAINROUT Logical Input VIDEO Name 1 2 3 SAFE VT01 VT02 001 002 001 002 001 002 001 002 LEFT RIGHT TC DATA 064 001 002 071826105_Switcher Input and Output Tables Switcher Output - MAINROUT Logical Output Security Name 1 2 VT01 VT02 - - S-T Pass Word VIDEO LEFT 001 002 001 002 RIGHT 001 002 TC 001 002 DATA 001 002 CP Input and Output Sets and Control Panel Operation The input and output names in the previous tables must be assigned to Category/Entry selections using a CP Input Set and CP Output Set. For example, if a CP-3000-type panel is to be used, the "C" (for "controller") category button could be used to select the controller (output) and the VCR category button could be used to select the VCRs. JUPITER CM-4400 Control Module Installation and Operating Manual 167 Section 5 -- The Configurator Application Switcher Output Table The Switcher Output table (Figure 120) performs similar functions as the Switcher Input Table except that it applies to outputs. Figure 120. Example of the Switcher Output Table The Switcher Output table is used to give each physical output a logical name in the Logical Output Name column. In Venus DM 400B data switching applications, the Switcher Output table is used to assign a logical name to each physical port connected to a "controller" device. Security Unlike the Switcher Inputs table, the outputs table has several provisions for security. A Security Board can be identified for an output by entering the name of a controller board in the Security field (such as "CM1"). This setting would limit switching the output to only controls that are connected to that board. The name must be one of those already entered in the Switcher Description Table. [. . . ] Ensure that the configuration set that is opened is the one that you want to change. Follow these steps to enter or modify the Serial Protocol table: 1. Select the Serial Protocol option from the Jupiter menu (Jupiter> Serial Protocol). The Serial Protocol table will then open (Figure 234). JUPITER CM-4400 Control Module Installation and Operating Manual 301 Appendix B -- Connecting Legacy and 3rd Party Routers Figure 238. Double-click the protocol box that is associated with the Serial port. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRASS VALLEY JUPITER CM-4400




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GRASS VALLEY JUPITER CM-4400 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.