User manual GE SECURITY RANGER 9000E REV C

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GE SECURITY RANGER 9000E. We hope that this GE SECURITY RANGER 9000E user guide will be useful to you.


GE SECURITY RANGER 9000E REV C: Download the complete user guide (639 Ko)

Manual abstract: user guide GE SECURITY RANGER 9000EREV C

Detailed instructions for use are in the User's Guide.

[. . . ] This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Connect the affected equipment and the Panel receiver to separate outlets, on different branch circuits. [. . . ] You can bypass all sensors for any security level in which they are active, except smoke, heat, and fire pull sensors. Indirect bypassing lets you bypass open sensors when the system will not arm. Direct Bypass lets you bypass sensors when the system is armed and operating normally. If the panel announces, Sensor [sensor #] open and sounds protest beeps, continue to step 2. If the panel arms successfully, you do not have to bypass any sensors. Sensor [sensor #] bypassed. NOTE: NOTE: The indirect bypass procedure shall not be used in UL listed installations. The indirect bypass procedure does not work when you arm the panel by pressing the COMMAND button rather than entering your access code. 2. s To bypass sensors indirectly from a Keychain Touchpad: 1. If the panel announces, Sensor [sensor #] open and sounds a two-beep continuous sequence (1 long, 1 short), continue to step 2. If the panel arms successfully, you do not have to bypass any sensors. 28 2. Press the Arm button again. Depending on which level you arm to, the panel's STAY or AWAY light turns on, the panel and interior sirens sound two or three beeps, and the panel announces, Sensor [sensor #] bypassed. NOTE: The indirect bypass procedure cannot be used in UL listed installations. s To bypass sensors directly: 1. The panel announces, [new primary access code] OK. NOTE: You can enter your current primary access code in place of a new primary access code if you do not want to change your code. 2. 3. Insert the Key into the slot within 30 seconds of changing your primary access code (see Figure 4). Hold the Key in the slot until the panel announces, Memory OK. 31 NOTE: You must reprogram the Magic Key whenever you change your primary access code. s To program Magic Key for temporary access: 1. The panel announces, [new temporary access code] OK. NOTE: You can enter your current temporary access code in place of a new temporary access code if you do not want to change your code. 2. Enter the number of days (00-99) you want the Key to work. If you enter 00, the Key will work until midnight of the day the Key is programmed. For numbers greater than 00, the Key will work until midnight of the assigned day. Insert the Key into the slot within 30 seconds of changing your temporary access code (see Figure 4). Hold the Key in the slot until the panel announces, Memory OK. NOTE: You must reprogram the Magic Key if you change the temporary access code. 3. 4. Magic Key Voice Messages Table 6 describes voice messages you may hear when programming or using a Magic Key. Table 6. Reprogram Key or revalidate the temporary access code. Using the Keychain Touchpad This section summarizes all the functions of the Keychain Touchpad. You can perform the following functions using the Keychain Touchpad: Arm the system Arm the system with no alarm delay time Disarm the system 32 s Activate an alarm Turn system-controlled lights on and off. [. . . ] alarm A Panel condition that occurs when a sensor is tripped, if the sensor is active in the current arming level that the system is set to. When arming to level 2, perimeter sensors, such as door/ window sensors, are monitored. When arming to level 3, all sensors, including interior sensors such as motion sensors, are monitored. auxiliary/medical alarm Activated by pressing the AUXILIARY/MEDICAL buttons. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GE SECURITY RANGER 9000E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GE SECURITY RANGER 9000E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.