User manual FOSTEX VR800Z SERVICE MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FOSTEX VR800Z. We hope that this FOSTEX VR800Z user guide will be useful to you.


FOSTEX VR800Z SERVICE MANUAL: Download the complete user guide (1435 Ko)

Manual abstract: user guide FOSTEX VR800ZSERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Service Manual Model VR800 VR800Z Digital Multitrack Recorder CAUTION: CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. ATTENTION: POUR ÉVITER LES CHOCS ÉLECTRIQUES, INTRODUIRE LA LAME LA PLUS LARGE DE L A F I C H E D A N S L A B O R N E C O RR ESPONDANTE DE LA PRISE ET POUSSER JUSQU' AU FOND. The lightening flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. "WARNING" "TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. " SAFETY INSTRUCTIONS 1. Read instructions - All the safety and operating instructions should be read before the appliance is operated. Retain instructions - The safety and operating instructions should be retained for future reference. [. . . ] - Connector J4, gate array U5, U20 and / or surrounding circuit are defective. · Defect on DIGITAL IN - Connector J5, gate array U5, U20 and / or surrounding circuit are defective. · The SETUP "DIGITAL IN" is set other than "L: - R: -". Even if the before mentioned prompt is displayed, pressing the [EXECUTE/YES] key would reach the next test. 14 VR800 / VR800Z 4-5-5. Adat In/Out Check By connecting the DATA IN and OUT terminals, this tests checks if the ADAT digital signal output by itself is correctly received. If the PLL circuit is not in a "LOCKED" condition, the prompt below will be displayed. - Connector J4, gate array U5, U20 and / or surrounding circuit are defective. · Defect on DIGITAL IN - Connector J5, gate array U5, U20 and / or surrounding circuit are defective. - PLL circuit (U22, 23, 35, 36, 37, 38, 39 and / or surrounding circuit) are defective. · The SETUP "DIGITAL IN" is set other than "L: - R: -". Even if the before mentioned prompt is displayed, pressing the [EXECUTE/YES] key would reach the next test. 4-5-6. Vari-Pitch Circuit Check Using the master clock generated through the VR800 vari-pitch circuit on the MAIN PCB, the adat digital signal is output. This test checks if the adat digital signal output by itself is correctly received. · Defects on the vari-pitch circuit (U3, U9), gate array (U5) and / or surrounding circuit. Even if the before mentioned prompt is displayed, pressing the [EXECUTE/YES] key would reach the next test. 15 VR800 / VR800Z 4-6. Offset Display : blinking This mode determines if the offset value against a master machine should be displayed when the VR800 is working as a slave machine. If you would like to turn "ON" the offset display, press the [EXECUTE/YES] key while "?" is blinking. (The default setting is "off". ) Then, turn the jog dial C. W. to change the setting to "ON" and press the [EXECUTE/YES] key. In order to check the offset value, select the "MTC" time base and the "REMAINING TIME" display. CAUTION: There might be a case that the percentage value does not indicate "0. 0%" exactly. This is caused by the difference of internal clocks between master and slave machines, which are running independently. 4-7. Initializing Disk : blinking This mode initializes an external SCSI device connected to the SCSI port or an internally installed drive. If both the external SCSI drive and the internal drive are connected at the same time, the current drive will be initialized. One is for recording / reproducing (SCSI ID: 0 ~ 5) and the other for exclusive backing up (SCSI ID: 6). Initializing is possible on the SCSI drive (ID: 0 ~ 5) used for recording / reproducing only. ? : blinking ? After pressing the [EXECUTE/YES] key, "SURE?" will start blinking in the FL display. [. . . ] C001 C002 C003 C004 C007 C008 C009 C010, 011 C012 CAPACITORs ALU = Electrolytic type CER = Ceramic type Part No. Description 8232157106 8232803103 8232157106 8232803103 8232801101 8232801101 8232801101 8232806330 8232803103 ALU, 16V, 10µF, 20%, SRA CER, 50V, 0. 01µF, +80-20%, YF ALU, 16V, 10µF, 20%, SRA CER, 50V, 0. 01µF, +80-20%, YF CER, 50V, 100pF, 5%, SL CER, 50V, 100pF, 5%, SL CER, 50V, 100pF, 5%, SL CER, 50V, 33pF, 5%, NPO CER, 50V, 0. 01µF, +80-20%, YF 26 VR800 / VR800Z Ref. J001 Q001, 002 S001~008 S009~016 S017~022 S025~031 S033~036 W001 W002 X001 MISCELLANEOUS Part No. Description 8245272117 8234100802 8253135002 8253135002 8253135002 8253135002 8253135002 8276779030 CONN, PL, JACK, FPC, 17P TR, VT, PNP, 2SA1150Y SW, PT, TACT, SKQNAB SW, PT, TACT, SKQNAB SW, PT, TACT, SKQNAB SW, PT, TACT, SKQNAB SW, PT, TACT, SKQNAB CABLE_ASSY, 9P, WHTMT/F-MT/ BS, L300 8277003010 CABLE_ASSY, 4P, MT-MT, BLU, L100 8256134003 RESONATOR, PF, CER, 8. 00MHZ, F5, EFOEN · LCD PCB ASSY Parts List Ref. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FOSTEX VR800Z




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FOSTEX VR800Z will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.