User manual FOSTEX D-80

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FOSTEX D-80. We hope that this FOSTEX D-80 user guide will be useful to you.


FOSTEX D-80 : Download the complete user guide (5219 Ko)

You may also download the following manuals related to this product:

   FOSTEX D-80 (11707 ko)

Manual abstract: user guide FOSTEX D-80

Detailed instructions for use are in the User's Guide.

[. . . ] Be sure to keep the removed hard disk carefully. APPENDIX (Operation manual for the recorder with the Model 8345 TC/SYNC card installed) Contents of Appendix Names and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Additional features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operations for the additional SETUP menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] SETUP mode [OffsetDisp ?] menu This menu selects whether or not displaying the real offset between the incoming reference timecode (LTC or MTC) and the displayed MTC (output LTC). The real offset is displayed instead of REMAIN when displaying the MTC. 6. GENERATOR setup functions The GENERATOR setup functions allows recording/erasing an external or internal (generator) timecode, forcejamming to external timecode, setting the LTC output, and setting the chase offset value between incoming timecode and the MTC. 4 APPENDIX (Operation manual for the recorder with the Model 8345 TC/SYNC card installed) "Clock Sel ?" menu setting Execute step 1 and 2 in ""Ref. Select the [Clock Sel?] menu by using the JOG dial and press the EXECUTE/YES key. The reference clock currently selected starts flashing (the default reference clock setting when the Model 8345 is installed is [INT]). SETUP "Sync Preset ?" menu setting Execute step 1 and 2 in ""Ref. Select the [Sync Preset ?] menu by using the JOG dial and press the EXECUTE/YES key. The sync preset setting currently selected is shown (the default setting when the Model 8345 is installed is [Int. Ana. ]). SETUP OL 0 3 6 9 12 18 24 30 42 44. 1kHz OL 0 3 6 9 12 18 24 30 42 44. 1kHz _ _ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SETUP SETUP OL 0 3 6 9 12 18 24 30 42 OL 0 3 6 9 12 18 24 30 42 44. 1kHz 44. 1kHz _ _ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 4. Select the desired reference clock by using the JOG dial. You can select from [Auto], [Word] and [Video] as well as [Int]. The following table shows the function of each option. Reference clock Function The reference clock is automatically selected from among available clocks according to the following order of priority; Word, Video and Int. Select the desired sync preset combination by using the JOG dial from the followings; [Int. The following table shows the function of each preset. Preset item Ana. setting Not assigned adat ;Async Not assigned adat ;Async Not assigned adat ;Async Not assigned adat ;Async Not assigned adat ;Async 8345 Clock Slave Type Auto Int Word Video Int. Also note that recording timecode does not consume the hard disk space. To erase all the timecode information, see "Erasing the recorded timecode" described later. The force jamming to the external timecode starts and the display shows the timecode value in real-time. If the 8345 does not receive external timecode correctly, the warning message [Void LTC In!] appears when pressing the EXECUTE/YES key. Selecting the output timecode When the timecode recording mode (described above) is set to [Free Run] or [24H Run], the 8345 can output the internal generator timecode or recorded timecode. Note that it does not output timecode when the timecode recording mode is set to [Rec Run] or [Ext Run]. <CAUTION> * While timecode is output, the recorder's vari pitch and word sync functions are prohibited. Note that the timecode output setting is available only when an "Async" mode ([adat:Async] or [SPDIF:Async]) is selected in the [D. * The [TC Out Sel?] setting returns to the default [Repro] when turning the power off. Editing the internal generator timecode Editing the internal generator timecode can be done only when the timecode recording mode (described above) is set to [Free Run]. 1. Select [Gen TC Set] of the Generator Setup mode and press the EXECUTE/YES key. The current internal generator timecode is displayed and you are now ready to edit the time. OL 0 3 6 9 12 18 24 30 42 44. 1kHz 1. Select [TC Out Sel?] ([?] flashes) of the Generator Setup mode and press the EXECUTE/YES key. The current output setting flashes (the default setting is [Repro]). _ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 OL 0 3 6 9 12 18 24 30 42 44. 1kHz OL 0 3 6 9 12 18 24 30 42 44. 1kHz _ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 _ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2. Use the SHUTTLE dial to move the editing point (which is flashing), and use the JOG dial to set the numeric value. Up to 23h59m59s**f (** = current frame rate - 1) can be set. OL 0 3 6 9 12 18 24 30 42 44. 1kHz _ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 3. Use the JOG dial to select [Repro] or [Gen. ]. The timecode output from the TIME CODE OUT terminal changes according to the setting. Output setting Output timecode Reproduced timecode Force jamming to external timecode Force jamming to external timecode can be done only when the timecode recording mode (described above) is set to [Free Run]. [. . . ] Feed the timecode from the VTR to the TIME CODE INPUT terminal of the recorder with the Model 8345 to play the recorder in sync with the VTR. Also feed the video reference signal to both the VTR and recorder as shown above. Timecode display You can monitor the incoming timecode in the D824/ D1624 display window. 1. Press the DISP SEL key while holding down the SHIFT key to select [MTC]. The display will show the current MTC offset value (the default setting is "00h59m57s00f"). Recorder settings 1. Set the recorder's frame rate to the same rate as the incoming timecode by the [Frame Rate ?] menu of the Setup mode. The [Frame Rate?] menu of the Setup mode allows you to select the desired frame rate from 24, 25, 29nd, 29df, 30nd and 30df. 2. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FOSTEX D-80




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FOSTEX D-80 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.