If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS CYBERSCAN PH 10 PHMV METER. We hope that this EUTECH INSTRUMENTS CYBERSCAN PH 10 PHMV METER user guide will be useful to you.
Manual abstract: user guide EUTECH INSTRUMENTS CYBERSCAN PH 10 PHMV METER
Detailed instructions for use are in the User's Guide.
[. . . ] Instruction Manual
CyberScan pH 10 & pH 100
Hand-held pH / mV / Temperature / RS 232 Meter
pH 10 Meter
pH/mV/°C
pH 100 Meter
pH/mV/°C/RS 232
68X007106 09/2001 rev 4
Technology Made Easy . . .
PREFACE
This manual serves to explain the use of the Standard CyberScan series hand-held meters. The models covered are the CyberScan pH 10 and the CyberScan pH 100 hand-held meters. The manual functions in two ways, firstly as a step by step guide to help the user operate the meter. This instruction manual is written to cover as many anticipated applications of the CyberScan pH meters as possible. [. . . ] As soon as the printer is ready, the error display will automatically go off. While the meter is displaying the printer error, you may press the `CAL/MEAS` key to go back to the measurement mode.
25
8. 2
Sending Data To Computer
To send data to the computer, connect the RS232C cable from the base of the CyberScan pH 100 to the communication port of the computer. Load and run the CYDATA data acquisition program ensuring that the parameters of the settings in the CyberScan pH 100 and the CYDATA are identical (See Section 10. 4 "Setting Up CYDATA" on page 37). 8. 2. 1 Printing Measurement Data To print any data that currently being measured, press the PRINT key as shown in the diagram below. Note that the PRINT capability is available for the [MEAS], [Rel mV] and [mV] modes. The data will be printed onto the printer paper or the screen of the CYDATA program automatically. 8. 2. 2 Printing Data From Memory The CyberScan pH 100 meter can print data that is stored in the memory. Firstly ensure that the cables are properly connected to either the printer or the computer and the units are configured to receive data from the meter. Change the mode to the mode of measurement from which data needs to be printed. For example, the data stored is in the memory location of the mV mode. Scroll to the data that needs to be printed by pressing the MR/" key. The data displayed will then be sent to the printer or the computer.
Parameter pH, Rel mV, mV Temperature Date Time Format mm/dd/yy hh/mm/ss
Note:
Abbreviation mm dd yy hh mm month date year hour minute
26
The data will be printed in the following format:
pH : 5. 41 pH : 5. 43 pH : 5. 74 pH : 6. 03 R. mv: 1. 4 R. mv: -1. 1 R. mv: -3. 2 R. mv: -4. 9 mv : -6. 9 mv : -8. 2 mv : -10. 3 mv : -11. . 2 mv : -12. 9 mv : -14. 1 mv : -15. 9 mv : -17. 4 mv : -17. 8 mv : -18. 6 mv : -19. 7 mv : -22. 5 mv : -20. 9 mv : -33. 0 pH : 5. 69 pH : 5. 45
Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0 Temp: 25. 0
Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996 Date: 12-21-1996
Time: 09:52:39 Time: 09:52:42 Time: 09:53:57 Time: 09:54:00 Time: 09:57:00 Time: 09:57:03 Time: 09:57:07 Time: 09:57:10 Time: 09:57:15 Time: 09:57:18 Time: 09:57:22 Time: 09:57:24 Time: 09:57:28 Time: 09:57:31 Time: 09:57:37 Time: 09:57:40 Time: 09:57:43 Time: 09:57:46 Time: 09:57:49 Time: 09:57:52 Time: 09:57:55 Time: 09:57:58 Time: 10:11:35 Time: 10:11:38
27
9
ADVANCED SETUP FUNCTIONS (FOR pH 100 ONLY)
The advanced setup mode lets you customized your meter's preferences and defaults. The Eutech Instruments' standard CyberScan meter features four different programs that organize all setup parameters. The programs and options are elaborated under the following sections:
Program P 1. 0 P 2. 0 P 3. 0 P 4. 0 Description Software Initialization View Electrode Data Meter Configuration Communication Data Setting Sub-Group Functions Memory Clear and Reset Options pH slope & offset, calibration data, & relative mV offset Set pH resolution, READY setting, & auto-off function Set baud rate, parity & stop bit. Section 9. 1 9. 2 9. 3 9. 4
To enter the SETUP mode, press the SET key from either the pH, Relative mV or mV measurement [MEAS] mode. There are some options that only permit the viewing of data and are useful for diagnostic purposes. Ensure that the CON key is pressed to confirm your option in each program. Should you desire to exit from the program after the confirmation of your choice or abort the [SETUP] mode, press the CAL/MEAS key to return to the [MEAS] mode. Addendum 1 shows the overall program setup and the factory default settings.
28
9. 1
Program 1 Software Initialization
This program deals with the initialization of the memory and calibration data. "OFF" is the default setting for both Memory Clear and Reset. 9. 1. 1 P1. 0 : Memory Clear
Activation of this option by selecting `ON` clears all stored measurement values in the memory (5 sets of values each for pH, mV and Rel. Under default condition this option is not activated (set to OFF).
Figure 27: P1. 0, Memory Clear
9. 1. 2
P1. 1 : Reset
Activation of this option by selecting `ON`, resets the instrument. [. . . ] EC-BU-4BX EC-BU-7BX EC-BU-10BX EC-BU-1BT EC-BU-4BT EC-BU-7BT EC-BU-10BT EC-BU-12BT EC-BU-4BS EC-BU-7BS EC-BU-10BS EC-RIN-WT EC-AST-PK EC-DPC-BT EC-RE-005 EC-ORP-PRE EC-ORP-QUIN EC-ORP-QUIN086
Note: pH buffer solutions (480-ml bottle) have ±0. 01 pH accuracy at 25 °C. Sachets are individually sealed, single use pouch containing 20 ml of fresh, contamination free calibration solution. pH buffer sachets have ±0. 01 pH accuracy at 25°C and conductivity sachets have ±1% accuracy at 25°C.
15. 3
Ion Selective Electrodes (ISE)
Ask our distributors for more details regarding Ion Selective Electrodes. The table below lists the range of electrodes available.
Ion Ammonia ( NH3) Ammonium (NH4+) Bromide (Br ) Cadmium (Cd ) Calcium (Ca+2) Carbon Dioxide (CO2) Chloride (Cl-) Copper (Cu+2) Cyanide (CN ) Fluoride (F-) Flouroborate (BF4-)
+2
Ion Lead (Pb+2) Lithium (Li+) Nitrate (NO3-) Nitrogen Oxide (NOX) Perchlorate (ClO4-) pH (H+) Silver/Sulfide (Ag+/S-2) Sodium (Na+) Sulfur Dioxide (SO2) Surfactant (X+, X-) Thiocyanate (SCN-)
-
57
15. 4
pH & ORP Electrodes
There is a wide range of electrodes for the user's applications. [. . . ]