User manual DOMETIC RM4200

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DOMETIC RM4200. We hope that this DOMETIC RM4200 user guide will be useful to you.


DOMETIC RM4200 : Download the complete user guide (13385 Ko)

Manual abstract: user guide DOMETIC RM4200

Detailed instructions for use are in the User's Guide.

[. . . ] Immediately call your gas supplier. WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information consult a qualified installer, service agency or the gas supplier. AVIS Cet appareil doit être réparé seulement par un réparateur autorisé. Modification de l'appareil pourrait être extrèmement dangeruse, et pourrait causer mal ou mort. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. REFRIGERATOR INSTALLATION & MODEL OPERATING INSTRUCTIONS RM 4223 Electrolux Siegen GmbH In der Steinwiese 16 D- 57074 Siegen 821 2686-04 04/99 INDEX Installation Operating Instructions Maint. & Service Page 2 7 10 Francais page 13 IMPORTANT INSTRUCTIONS READ CARFULLY SECTION A. [. . . ] Bubbles indicate a gas leak and the safety valve must be replaced by a qualified serviceman. Light the burner and allow it to burn for five minutes. IMPORTANT: To prevent the refrigerator from being left on and draining the battery when the vehicle's engine is not running and charging the battery, it is recommended that an automatic cutout relay be installed between the battery and the refrigerator toggle switch so that the refrigerator will not draw current when the vehicle ignition is switched off. Alternatively, a suitable plug and receptacle should be installed in the 12V supply line so that the refrigerator can be disconnected from the supply, as necessary. FUSE A 12 amp (continuous rating) fuse should be incorporated in the wiring of the DC supply, as near to the battery as possible. The fuse must be in the side of the wiring which is not connected to the chassis. For example, if the vehicle has a negative ground, the fuse must be in the positive side of the wiring. 10. 120 VOLT AC ELECTRICAL CONNECTION The refrigerator is equipped with a three-prong (grounded) plug for protection against shock hazards, and should be plugged directly into a properly grounded three-prong receptacle. The power cord should be routed to avoid direct contact with the burner cover, fuel cover or manual gas shutoff valve knob. 12. CHANGING DOOR HINGES FROM ONE SIDE TO THE OTHER If required, the door hinges can be moved to the opposite side. Unscrew the upper hinge pin, taking care not to lose the set of washers and bushings. Change the cover plate and travel lock plate in top of door frame to opposite side. Use needle-nosed pliers to carefully lift lock plate out of door frame. When parked close to a gasoline pump, it is possible that the gasoline fumes could enter this type of appliance and ignite from the burner flame, CAUSING A FIRE OR AN EXPLOSION. FOR YOUR SAFETY, it is recommended that all LP gas appliances which are vented to the outside should be shut off when refueling. The refrigerator must be shut off during refueling. If possible, start the refrigerator on gas or AC the day before it is to be used, to allow time for the interior to be cooled. It is then preferable to load the refrigerator with food which has been precooled in your household refrigerator, or in the market. Before moving the vehicle, make sure that all containers are tightly covered to avoid spills. If required, crumpled paper may be packed between bottles and other items to prevent shifting while traveling. Engage the travel catch at the top of the front corner of the door before moving the vehicle. then turn off the gas valve or switch of the DC/AC supply to the refrigerator. Leave the refrigerator door open and place a suitable dish or other receptacle under the evaporator to catch the defrost water. When all the frost has melted, any remaining drops of water in the refrigerator should be wiped up with a clean cloth. B. ELECTRIC OPERATION 12V DC / 120V AC OPERATION In the case of the RM4200, the refrigerator works continuously on DC operation (no thermostat control). [. . . ] 9 7) Reassemble the components in the reverse order to that described above. CLEANING OF FLUE TUBE, FLUE BAFFLE Proceed as follows: 1) To clean the flue tube and the flue baffle, it is neces sary to withdraw the refrigerator out of the recess. 3) Place a piece of paper or cloth between the boiler tube (E, in FIG. Cleaning of Burner, Burner Jet (Refer to FIG. 11) Proceed as follows: 1) Turn off the gas at the gas bottle. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOMETIC RM4200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DOMETIC RM4200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.