[. . . ] - Very low temperature setting considerably increase power consumption. - Avoid continuous direct air flow on you or a sick person while sleeping. This air-conditioner must used 20°C(min)-43°C(max) outdoor and 20°C(min)~32°C(max) indoor on the temperature range. The appliance is not intended for use by young children or infirm persons without supervision. [. . . ] Determine Correct Mounting procedure-Refer to Window Installation or Through the Wall Installation. · Contact service man for replacement of power cord.
3
· HOW TO REMOVE THE FRONT GRILLE
1. (when the knobs are too tight to release, leave them. )
;;;; ;;;;; ;;;; ;;;;; ;;;; ;;;;; ;;;; ;;;;; ;;;; ;;;;; ;;;; ;;;;; ;;;; ;;;;; ;;;; ;;;;; ;;;; ;;;;; ;;;; ;;;;; ;;;; ;;;;; ;;;; ;;;;;
4. Push the right lower side of chassis to the left, with pushing left side of Front Grille to the right until the snap-fit is released.
Push
Push
2) Release left-lower snap-fit. Push the left-lower side of chassis to the right, with pushing right side of Front Grille to the right until the snap-fit is released.
Push Push
3) Pull lower side of the Front Grille until it is separated from the chassis. (when knobe remain, pull Front Grille until knobs are released from control)
4) Push base side of the Front Grille to upper side until it is separated from the chassis.
4
5. Reinstall the unit, side screws, front grille.
CAUTION
· When the front grille is reinstalled, the DOOR VENT should be in position first so that it would not be bent by grille.
Door Vent
5
· HOW TO INSTALL THE DRAIN CAP
Install the drain cap like Fig. The first method is that the shape of hole like It is good for the household. The second method is that the shape of hole is like It is good for the shop.
The rear side of the unit SEAL DRAIN Drain Cap
M4x8 SCREW: Use Screw(M4x8) only.
· WINDOW INSTALLATION
1. The window where the Air Conditioner is to be installed should have enough strength to bear the weight of the Air Conditioner. Install the Air Conditioner using the Mounting Angle or other Hardware to be installed as shown in Fig. 1 For proper drainage, Rear side of the unit should be inclined about 5mm lower.
Mounting Angle Close up the gap
unit
5mm
wall
Fig. Finish opening Close up the gap between unit and window using the sponge or tape for insulation as shown in Fig. 1 * If through the wall installation is required, you may choose to consult an independent servicing Dealer. 6
NAMES OF MAJOR COMPONENTS
3
7 4
2
8
1
5
6
NO 1 2 3 4
PART NAME AIR FILTER GRILLE FRONT CABINET BLADE VERTICAL
NO 5 6 7 8
PART NAME KNOB THERMOSTAT KNOB SELECTOR BLADE HORIZENTAL AIR VENT
7
OPERATING INSTRUCTIONS
NOTE · FOR MOST ECONOMICAL USE
1. Do not leave doors and windows open.
· FAN & COOLING CONTROL
The Fan Control Selector Switch has six positions. Choose one of the speed settings by rotating the fan control Selector Switch to the appropriate position.
CAUTION
When the air conditioner has been performing its cooling operation and is turned "OFF" or set to the `FAN" position, wait at least 3 minutes before resetting to the cooling operation.
OFF HIGH FAN LOW FAN LOW COOL MED COOL HIGH COOL
Select this setting for stop all operation of air conditioner Select this setting for high air circulation without cooling. Select this setting for cooling operation with HIGH FAN.
· TEMPERATURE CONTROL
Choose a temperature settings by rotating the knob of thermostat to the appropriate position
NOTE
Setting the control at the coldest extreme of the temperature range will not cool the room any faster. If the room temperature is not satisfactory after a reasonable period of time, adjust the temperature control to a lower or higher setting.
· The Thermostat automatically starts and stops cooling operation in order to keep the room temperature at a proper level, and this results in efficient use of power and economical cooling. · Turn counter-clockwise for a warmer room temperature.
8
GENERAL INFORMATION
· CHANGING AIR FLOW DIRECTION
Air flow deflectors divert air from center flow to left or right and up or down. Adjust deflectors for desired air flow pattern.
· AIR FLOW AROUND UNIT
Check in door grill and outdoor louvers for air flow obstructions. The outdoor coil should be checked and periodically cleaned for debris that may collect and block unit air flow. If air flow is obstructed or deflected back into unit, the compressor may cycle on and off rapidly, causing early compressor failure.
· DRAIN HOLE AND WATER DRIPPING OUTSIDE
Locate drain hole at the rear or on the bottom of unit. [. . . ] · When blocked by curtains, blinds, or furnitures, etc. , the air flow is restricted and cooling performance is affected. · Check with dealer to determine proper unit capacity for application. · Stop noise by allowing water to drain from base fan through drain hole. · Place algaecide tablet in base pan · Remove water in base pan through drain hole. [. . . ]