User manual DAEWOO DSB-182L [REVISION EDITION]

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DAEWOO DSB-182L [REVISION EDITION]. We hope that this DAEWOO DSB-182L [REVISION EDITION] user guide will be useful to you.


DAEWOO DSB-182L [REVISION EDITION] : Download the complete user guide (427 Ko)

Manual abstract: user guide DAEWOO DSB-182L [REVISION EDITION]

Detailed instructions for use are in the User's Guide.

[. . . ] SAFETY INSTRUCTIONS PLEASE READ THE FOLLOWING SAFETY INSTRUCTIONS BEFORE INSTALLING AND OPERATING THE UNIT: This air conditioner meets strict safety and operating standards. The installer of this unit must install or service this unit so it operates safely and efficiently. Precautions When Wiring: · Do not plug in the unit until all connections (tubing, drain hose, mounting, etc. ) have been made and double-checked. · High voltages are present in this unit and are very dangerous. Improper connections or inadequate grounding can cause accidental injury. [. . . ] Insert the attached AC plug into a 2pronged 220V~ 240V AC outlet. NOTES: AC Outlet and Plug Plug intoPlug into 220V AC Outlet 220V~240V AC Outlet. · Never connect the AC line cord plug to other than the specified voltage (220V~240V). · If the outlet is a 3-pronged type or other, have an electrician install a new outlet. · The new air conditioner system should be on it's own 220V circuit. Contact your local electrical installer for installation. HOW TO INSTALL BATTERIES To install the batteries, follow the procedures below: 1. Insert two "AAA" size Alkaline batteries following the polarity diagram below. TIMER ON/OFF ENTER/ CANCEL TURBO/MILD ­ + BATTERY PRECAUTIONS The precautions below should be followed when using batteries in this device: 1. Be sure to follow the correct polarity when installing the batteries as indicated in the battery compartment. If the device is not to be used for a long period of time, remove the batteries to prevent damage or injury from possible battery leakage. Do not try to recharge batteries not intended to be recharged; they can overheat and rupture. (Follow battery manufacturer's directions). SETTING THE UNIT FOR REMOTE OPERATION After the unit is fully connected and plugged in, it can be turned on. To turn the unit on and set it for remote operation, follow the procedures below: 1. Open the indoor unit's cover and make sure the EMERGENCY/REMOTE switch is set to the REMOTE position; this will allow the unit to operate with the remote controller. The On LED will light on the indoor unit and "ON" will light in the remote display. To select the various modes and settings, read the following pages. EMERGENCY/REMOTE Switch THREE MINUTE COMPRESSOR DELAY EMERGENCY REMOTE · After turning the indoor unit on and setting it for air conditioner operation, the compressor (outdoor unit) will not come on for three minutes. This is a feature that will protect the compressor from damage due to quick start and stops. 8 ­ + CELSIUS TO FAHRENHEIT CONVERSION CHART CELSIUS 18 19 20 21 22 23 24 25 FAHRENHEIT 64. 4 66. 2 68 69. 8 71. 6 73. 4 75. 2 77 CELSIUS 26 27 28 29 30 31 32 FAHRENHEIT 78. 8 80. 6 82. 4 84. 2 86 87. 8 89. 6 NOTES: · When operating the remote controller, make sure there are no obstructions between the remote controller and the remote sensor. · After a while the display goes blank to conserve battery power. To check the settings, press the ON/OFF button once. TO SET THE UNIT TO AUTO MODE This unit will automatically operate the unit according to its surroundings while in the Auto mode. All you have to set is the desired temperature and it will control the fan, coolness and dehumidifier. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and "ON" will light in the remote display. The desired temperature can be changed up or down 1 degree from the actual room temperature. Then the unit will automatically operate. AUTO 9 TO OPERATE ONLY FAN To operate only the fan so the unit will circulate the air, proceed as follows: 1. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and "ON" will light in the remote display. To select a fan speed, press the FAN SPEED button until the desired speed appears in the display (see below). FAN SPEEDS "" "" "" "NATURAL" The fan will operate on low speed. [. . . ] Open the indoor unit's cover and make sure the EMERGENCY/REMOTE switch is set to the EMERGENCY position. The unit will then turn on and depending on the room temperature, it will select the cool or dehumidifier mode, fan speed and fan direction automatically. EMERGENCY/REMOTE Switch 3. To turn the unit off, slide the EMERGENCY/ REMOTE switch to the REMOTE position. EMERGENCY/REMOTE Switch 14 CHANGING/CLEANING THE AIR FILTERS To change or clean the two black air filters, follow the procedures below: 1. Open the indoor unit's cover and remove both black air filters by bending them slightly backward and the lifting out. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAEWOO DSB-182L [REVISION EDITION]




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DAEWOO DSB-182L [REVISION EDITION] will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.