User manual DAEWOO DOC-090RH

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DAEWOO DOC-090RH. We hope that this DAEWOO DOC-090RH user guide will be useful to you.


DAEWOO DOC-090RH : Download the complete user guide (1630 Ko)

Manual abstract: user guide DAEWOO DOC-090RH

Detailed instructions for use are in the User's Guide.

[. . . ] Avoid prolonged direct exposure of your body to the cold air. Keep children cautious not to stick their fingers or metal sticks into the opening of the product indifference can result in a severe case of shock or malfunction of this appliance. Place this appliance on flat surface which makes it stand always straight up. - 12- CONTENTS Advantages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 I I 3 4 5 6 7 8 9 10 I I I I CONTENTS Advantages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Convenient Portability This air conditioner is compact and has strong air conditioning function, light weight with high efficiency, lesser noise and easy to move even in a small space. 2. [. . . ] Push the duct fitting A into the duct hole of main body as shown below 4. When the installation of duct is finished, turn the air conditioner on by switch or remote controller. Duct fitting A 2. For moving the air conditioner, hold the handles on both side and move it to the desired place. - 6- INSTRUCTION I * Before starting air conditioner, see to it that the appliance is properly placed and all doors and windows are closed intact. 1. Select MODE switch on air conditioning(T ) and select desired temperature. 5. When the water container is full, the beefer will signal and the warning lamp will blink simultaneously, and then water container should be emptied. (See page 10) - 7- INSTRUCTION II * Before starting air conditioner, see to it that the appliance is properly placed and all doors and windows are closed intact. 2. When the water container is full, the beefer will signal and the warning lamp will blink simultaneously, and then water container should be emptied. Heating Set the Mode switch on Heating( ). * Ambient temperature for air conditioning and dehumidifying is 18 C- 35 C. When the ambient temperature is below 18 C, the compressor will not function and the temperature lamp will blink simultaneously while the fan will start for removing the frost. * When the function of air conditioning and dehumidifying is stopped, it will not operate for approximately 3 minutes in order to prevent overload of compressor; but it will be fanning for approximately 3 minutes, and then both air conditioning and dehumidifying will start again. - 8- HOW TO CLEAN AND HANDLE THE FILTER * When the filter is contaminated with dust, clean the filter once in every 2 weeks, lest it should decrease the fanning function. 1. Remove the filter by pulling toward the arrows shown below. 3. Clean the filter in a neutral detergent dissolved water (appr. 30¡£ C) and dry well in the shadow. 4. Outside Clean the outside with wet soft cloth soaked in neutral detergent dissolved water, and then dry it with a clean soft cloth thoroughly until the neutral detergent is completely removed. * When handling and cleaning the filter as directed above, see to it that the power connector is disconnected. * When the evaporator is contaminated with dust, the efficiency of air conditioning will be decreased. (Use air conditioner cleaning spray. ) Evaporator - 9- HOW TO HANDLE WATER * When the air conditioner and dehumidifier are in operation, the humid indoor air will produce water drops. 1. When the water container is full, the warning lamp will blink and the air conditioning will be stopped while the warning lamp is keep blinking until the water container is emptied and replaced. As soon as the water container is replaced, start air conditioning or dehumidifying. * When disposing the less full water, the power switch should be turned off and pull out the water container more than 3 minutes later. If the container is pulled out immediately, remaining water will drop inside of the appliance. * Do not pull out the water container while the appliance is in operation because the remaining water will drop inside. [. . . ] Does the product stand titled? Replace either the plug or the outlet Place the product on flat surface. The sound comes from auxiliary pips in which refrigerant flows. Is the product functioning all right? Specification MODEL Cooling Capacity Heating Capacity Dehumidification Power Supply Power Consumption Net Dimension 780(H)X330(W)X390(D) mm. DOC- 090RH 9, 000BTU/ h 1. 2 kW 50 pints/ day 24 / day AC 115V, 60Hz, Single Phase 930 watts 30. 7(H)X13. 0(W)X15. 4(D) inch 63. 9 Ibs. Net Weight 29 kg - 13- LIMITED WARRANTY DAEWOO DAEWOO ELECTRONICS CORPORATION OF AMERICA warrants the following window room air- conditioner to be free from defective material and workmanship and agrees to remedy any such defect or to furnish a new part (at the Company's option) in exchange for any part of any unit of its manufacture which under normal installation, use and service disclosed such defect, provided the unit is delivered by the owner to store or dealer where purchased or Daewoo authorized service center. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAEWOO DOC-090RH




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DAEWOO DOC-090RH will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.