If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DA-LITE TENSIONED LARGE ADVANTAGE ELECTROL. We hope that this DA-LITE TENSIONED LARGE ADVANTAGE ELECTROL user guide will be useful to you.
You may also download the following manuals related to this product:
DA-LITE TENSIONED LARGE ADVANTAGE ELECTROL DATASHEET (372 ko)
DA-LITE TENSIONED LARGE ADVANTAGE ELECTROL SPECIFICATION DATA (309 ko)
Manual abstract: user guide DA-LITE TENSIONED LARGE ADVANTAGE ELECTROL
Detailed instructions for use are in the User's Guide.
[. . . ] ositionthecordsothatitwillnotbetrippedover, pulled, orcontacthotsurfaces. Ifanextensioncordisnecessary, acordwithacurrentratingatleastequaltothatoftheappliance shouldbeused. Cordsratedforlessamperagethantheappliancemayoverheat. Toreducetheriskofelectricshock, donotimmersethisapplianceinwaterorotherliquids. [. . . ] Placetherollerassemblyintothecasewiththemotorontheleftside. Thelimitswitchesshouldbefacingdown. Loosenfourboltsthatsecurepinendmountingbracketintohousing. Liftpinendofrollerintopositionandslide thebracketintotherollerpin. Tightenallfourbolts. 7 Completeelectricalhook-upbysnappingmotor1/3wireconnectorsintocaseconnectors. Returntomotorendandinsertsafetyclipovercastingbrackettosecuremotorend. Carefullyremovetapestripssecuringpicturesurfacearoundroller. Slatshouldmovefreely(Fig. 2). (Onlyifthe rollerassemblyispreinstalled. ) 10. Testinstallationbyoperatingthescreenseveraltimes. Bepreparedtostopthescreen. Thedoorassemblywillnot closeuntilthewallswitchisplacedintheuppositionandwhenthescreenmotorstopsatitslimitswitchintheup direction. If this happens the motor will shut off until it cools to a normal operating temperature. Closedoorassemblyandreplacefourboltsatendsofdoor(2boltsoneachend)(Fig. 1).
!REMOVE BY HAND.
OPTIONALLVC CONTROLBOX
SCREENMOTOR LIMITSWITCHES SCREENMOTOR
FIGURE 2
2
SCREEN ADJUSTMENT
Surfacetravelisstoppedautomaticallyinthefullyopenedandclosedpositionsbylimitswitchesthatareproperly adjustedatDa-Lite. Shoulditbenecessarytoadjustformoreorlessdropofpicture, proceedinthefollowingmanner: NOTE: Useascrewdriveror5/32"Allenwrenchtomakeadjustments.
MORE SCREEN DROP
1. henthescreenstops, turnthewhite"down" limitknob(Fig. 2)one-quarterturncounterclockwise. Testbyraising W picturesurfaceapproximatelytwofeet, thenloweragain. Repeatuntildesiredpicturesurfacepositionisattained.
!See the specification data sheet for details.
LESS SCREEN DROP
1. urnthewhite"down"limitswitch(Fig. 2)one-quarterturnclockwise. Testbyraisingpicturesurfaceapproximately T twofeet, thenloweragain. Repeatuntildesiredpicturesurfacepositionisattained.
3
TENSIONED LARGE ADVANTAGE® ELECTROL® INSTRUCTIONS
120V WIRING DIAGRAM
JUNCTION BOX MOUNTED INTERNALLY ON SCREEN CASE WHITE BLACK RED GREEN
MOTOR
WHITE BLACK (DOWN) RED (UP) SPDT SWITCH WITH CENTER OFF BLACK UP OFF DOWN THIS SWITCH CANNOT BE USED WITH LVC RED AC HOT 120VAC 60HZ 1 AMP BLACK/YELLOW NOTE: A SINGLE SWITCH CANNOT BE USED TO OPERATE MORE THAN ONE SCREEN. AC COMMON
240 VOLT WIRING DIAGRAM FOR STANDARD WALL SWITCH: Da-Liteofferstwostylesof240voltwallswitchesfor standardoperation. Pleaseseewiringdiagramincluded inwallswitchboxincludedwithscreen.
4
TENSIONED LARGE ADVANTAGE® ELECTROL® INSTRUCTIONS
120V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL
FRONT OF WALL SWITCH
BACK OF WALL SWITCH NOTE: 20-24AWG WIRE RECOMMENDED FOR CONNECTING WALL SWITCH TO LOW VOLTAGE CONTROLLER.
UP
STOP
DOWN
RED (UP) WHITE (COMMON) "EYE" PORT PLUG "IR" OR "RF" REMOTE HERE
WHITE (COMMON)
POWER INPUT 120VAC / 60HZ
GREEN (GROUND) BLACK (HOT) WHITE (COMMON) BLACK (DOWN)
WHITE (COMMON
BLACK (DOWN)
NOTE: DO NOT USE 3-POSITION HIGH VOLTAGE ROCKER SWITCH WITH THIS UNIT!THIS WILL DAMAGE THE LOW VOLTAGE CONTROL BOARD.
BLACK (DOWN) RED (UP)
RED (UP)
GREEN (GROUND)
GREEN (GROUND)
SCREEN MOTOR
5
TENSIONED LARGE ADVANTAGE® ELECTROL® INSTRUCTIONS
240V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL
FRONT OF WALL SWITCH
UP
BACK OF WALL SWITCH
NOTE: 20-24AWG WIRE RECOMMENDED FOR CONNECTING WALL SWITCH TO LOW VOLTAGE CONTROLLER. BROWN (HOT) BLUE (COMMON)
STOP
DOWN
WIRE NUT RED (UP) WHITE (COMMON) GREEN/YELLOW (GROUND) BLACK (DOWN)
"EYE" PORT PLUG "IR" OR "RF" REMOTE HERE BLACK
POWER INPUT 240VAC / 50HZ
GREEN/YELLOW (GROUND)
WIRE NUT
BLUE (COMMON)
BLUE (COMMON BROWN (DOWN) BLACK (UP)
BLACK (UP) NOTE: DO NOT USE 3-POSITION HIGH VOLTAGE ROCKER SWITCH WITH THIS UNIT!BROWN (DOWN)
GREEN/YELLOW (GROUND)
GREEN/YELLOW (GROUND)
SCREEN MOTOR
6
TENSIONED LARGE ADVANTAGE® ELECTROL® INSTALLATION
9 /8"
1
(SUGGESTED)1/2" THREADEDROD(NOT INCLUDED)ATTACHED TOMOUNTING BRACKET
SCREENROLLER
AUDIENCE SIDE 123/16" 11" 11 /16"
7
FINISHED CEILING
SELF-TRIMMING FLANGE 131/8"
SELF-TRIMMING FLANGE
23/16"
1015/16"
ACCESSDOOR
11"
VARIABLE POSITION MOUNTING BRACKETS
CASELENGTH 81/2"
111/2" ELECTRICAL JUNCTIONBOX 81/2"
7
TROUBLESHOOTING
SYMPTOM 1. [. . . ] IfitisnecessaryforthedealertoreturnthescreenorparttoDa-Lite, transportationexpenses toandfromDa-LitearepayablebythepurchaserandDa-Liteisnotresponsiblefordamagein shipment. Toprotectyourselfagainstdamageorlossintransit, insuretheproductandprepayall transportationexpenses. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY. Anyimplied warrantiesoffitnessforuse, ormerchantability, thatmaybemandatedbystatuteorruleoflaw arelimitedtotheone(1)yearwarrantyperiod. Thiswarrantygivesyouspecificlegalrights, and youmayalsohaveotherrights, whichvaryfromstate-to-state. NO LIABILITY IS ASSUMED FOR EXPENSES OR DAMAGES RESULTING FROM INTERRUPTION IN OPERATION OF EQUIPMENT, OR FOR INCIDENTAL, DIRECT, OR CONSEQUENTIAL DAMAGES OF ANY NATURE. IntheeventthatthereisadefectinmaterialsorworkmanshipofaDa-Liteproduct, youmay contactourSalesPartnersatPOBox137 , Warsaw, IN46581-0137 , (574)267-8101, (800)622-3737 . [. . . ]