User manual DA-LITE TENSIONED HORIZON ELECTROL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DA-LITE TENSIONED HORIZON ELECTROL. We hope that this DA-LITE TENSIONED HORIZON ELECTROL user guide will be useful to you.


DA-LITE TENSIONED HORIZON ELECTROL : Download the complete user guide (300 Ko)

You may also download the following manuals related to this product:

   DA-LITE TENSIONED HORIZON ELECTROL DATASHEET (75 ko)
   DA-LITE TENSIONED HORIZON ELECTROL DATASHEET (75 ko)
   DA-LITE TENSIONED HORIZON ELECTROL DATASHEET (109 ko)
   DA-LITE TENSIONED HORIZON ELECTROL DATASHEET (381 ko)

Manual abstract: user guide DA-LITE TENSIONED HORIZON ELECTROL

Detailed instructions for use are in the User's Guide.

[. . . ] To reduce the risk of electric shock, do not disassemble this appliance. Incorrect reassembly can cause electric shock when the appliance is used subsequently. The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire, electric shock, or injury to persons. SAVE THESE INSTRUCTIONS PRE-INSTALLATION 1. Make sure to recheck measurements of screen location before installation. BUS INTERFACE UNIT CONTROL WIRES JUNCTION BOX MASK MOTOR #2 MASK SURFACE ELECTRICAL OUTLET ON THIS END OF CASE TRANSFORMER JUNCTION BOX DRYWALL SCREW ACCESS PANEL MACHINE SCREW HEX HEAD SCREW SHIPPING BRACKET SCREEN MOTOR #1 SLATS PICTURE SURFACE FIGURE 1 1 FIGURE 2 INSTALLATION 1. [. . . ] 2 Sets format to HDTV (1. 78:1) 3 Sets format to Letterbox (1. 85:1) 4 Sets format to Anamorphic (2. 35:1) SCREEN ADJUSTMENT ADJUSTING THE SCREEN The motors on the Horizon Electrol® have been preset to four different screen formats based on your screen size. If you want to change formats we suggest you contact your Da-Lite Dealer to make the adjustments for you. The mask surface and the projection screen must be adjusted separately. The following instructions walk you through this process. 2 SCREEN ADJUSTMENT SCREEN ADJUSTMENT (MOTOR 1) 1. Remove the cover plate from the wall switch, and then remove the switch from the box. If you go past the desired position, press the stop button to stop the screen and then press the up arrow to return the screen to a position above the new stop point and try again until the screen stops at the new position. The new stop point can now be assigned to whichever format location you want, button 2, 3 or 4. Repeat this process for any other changes to the remaining 2 locations. Make sure the power is disconnected to the screen, then insert the T4 cable marked motor 2 in the jack it was disconnected from on the bus interface control and reconnect the T6 cable to the T6 adapter. If you go past the desired position, press the stop button to stop the mask and then press the up arrow to return the mask to a position above the new stop point and try again until the mask stops at the new position. The new stop point can now be assigned to whichever format location you want, button 2, 3 or 4. Repeat this process for any other changes to the remaining 2 locations. Make sure the power is disconnected to the screen, then insert the T4 cable marked motor 1 in the jack it was disconnected from on the bus interface control, shut the cover and fasten the screw. LIMIT CONTROL ADJUSTMENT This procedure will reset the stop positions for the "up" button and button 1. If you have a wall switch with just two T6 connectors on the bottom you will need to use a separate 3-button switch for this operation. Otherwise you will use the wall switch that controls the bus interface unit. Remove cover screw from bus interface unit located on the motor end of screen case. Locate the T4 wires coming from the motors to the bus interface (see wiring diagram). Unplug the T4 wire of the motor to be adjusted from the bus interface unit and plug it into the top left RJ22 4-pin connector of wall switch. Press and hold the 1 button on the switch to run the screen down to the desired position. [. . . ] CONTACT CLOSURE MUST BE MAINTAINED FOR AT LEAST 1 SECOND AND NOT MORE THAN 3 SECONDS. A STOP COMMAND IS SENT BY SIMULTANEOUSLY SENDING AN UP AND DOWN CONTACT CLOSURE. MOTOR 2 120VAC-24VDC TRANSFORMER MOMENTARY DRY CONTACT INPUTS Up Down Common MOTOR 1 BROWN BLUE GROUND T4 1 T6 2 TO 1 T6 ADAPTOR GROUND BROWN MOTOR 2 NOTE: ALL 4 OR 6 CONDUCTOR TELEPHONE WIRES MUST HAVE THE CONNECTORS ORIENTED THE SAME ON BOTH ENDS. DO NOT REVERSE THE CONNECTORS AS IS COMMONLY DONE WITH TELEPHONE EQUIPMENT. SEE SUPPLIED WIRE FOR CORRECT ORIENTATION. T6 BLUE 6-BUTTON WALL SWITCH RECEPTACLE FOR MAIN POWER CONNECTION AND 24VDC TRANSFORMER PLUG IN BROWN BLUE GROUND 240VAC 60 HZ EXTERNAL WIRING 4 SUGGESTED METHODS OF INSTALLATION SELECT INSTALLATION METHOD ACCORDING TO CEILING TYPE. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DA-LITE TENSIONED HORIZON ELECTROL




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DA-LITE TENSIONED HORIZON ELECTROL will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.