User manual DA-LITE TENSIONED COSMOPOLITAN ELECTROL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DA-LITE TENSIONED COSMOPOLITAN ELECTROL. We hope that this DA-LITE TENSIONED COSMOPOLITAN ELECTROL user guide will be useful to you.


DA-LITE TENSIONED COSMOPOLITAN ELECTROL : Download the complete user guide (408 Ko)

You may also download the following manuals related to this product:

   DA-LITE TENSIONED COSMOPOLITAN ELECTROL DATASHEET (170 ko)
   DA-LITE TENSIONED COSMOPOLITAN ELECTROL DATASHEET (179 ko)
   DA-LITE TENSIONED COSMOPOLITAN ELECTROL DATASHEET (191 ko)
   DA-LITE TENSIONED COSMOPOLITAN ELECTROL DATASHEET (352 ko)
   DA-LITE TENSIONED COSMOPOLITAN ELECTROL ANNEXE 500 (410 ko)
   DA-LITE TENSIONED COSMOPOLITAN ELECTROL SPECIFICATION DATA (61 ko)
   DA-LITE TENSIONED COSMOPOLITAN ELECTROL FOR SIZES UP TO 10X10 (409 ko)

Manual abstract: user guide DA-LITE TENSIONED COSMOPOLITAN ELECTROL

Detailed instructions for use are in the User's Guide.

[. . . ] NOTE: Must be installed in accordance with the requirements of the Local Building Codes, the Canadian Electrical Code (CEC), CAN/ CSA C22. 1 and the National Electric Code (NEC), NFPA 70. 1 TENSIONED COSMOPOLITAN® ELECTROL® INSTALLATION MOTOR END OVERALL LENGTH OF CASE 3/4" DIAMETER HOLE FOR WALL INSTALLATION BETWEEN HANGER EYES 4 5/8" 13/32" 1 7/8" 3/8" DIAMETER FOR CEILING MOUNTING 5 7/8" ENCLOSURE COVER 7/8" DIAMETER OPENING FOR ELECTRICAL SETTINGS PICTURE SURFACE OVERALL LENGTH OF SLAT SLAT FIG. 2 WIRING ENCLOSURE COVER 120V WIRING DIAGRAM TO JUNCTION BOX, MOUNTED IN SCREEN CASE, IN WHICH INTERNAL WIRING TERMINATES IN WHITE, BLACK AND RED LEADS DOWN BLACK UP RED COMMON WHITE DOWN WHITE LIMIT SWITCH ADJUSTMENT BLACK ROCKER SWITCH UP OFF DOWN WHITE RED BLACK WITH YELLOW SIDE VIEW OF SWITCH AND BOX OPERATING SWITCH AND PLATE FURNISHED WITH SCREEN. AMP IN MULTIPLE CONTROL INSTALLATIONS THIS SWITCH IS REPLACED BY THE LOW VOLTAGE CONTROL, OPERATED FROM PUSH BUTTON STATIONS. THIS SWITCH CANNOT BE USED WITH LVC. NOTE: A single switch cannot be used to operate more than one screen. Contact the factory for further information. FIGURE 3 240 VOLT WIRING DIAGRAM FOR STANDARD WALL SWITCH: Da-Lite offers two styles of 240 volt wall switches for standard operation. [. . . ] TO INCREASE SCREEN DROP: Turn the white limit switch screw counterclockwise to increase the amount of screen drop. If the screen does not drop enough, raise the screen about one foot and adjust the limit switch again. This screen comes standard with 12" black at the top. NOTE: The slat bar will not retract completely into the case. DO NOT adjust the up limit travel any higher than the factory preset position or damage may occur. 4 SCREEN ADJUSTMENT FOR 120V SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL OR VPI 1. Locate the wall switch and remove the cover plate from the 3-button wall switch and remove the switch from the junction box. To adjust the down limit switch, press and hold the down tactile button until the LED on back of switch turns solid red. If you travel to far down you can press the up to move the screen upward. If you press and let go of either up or down button the motor will do a small jog in that direction for finer adjustment of screen. Once desired position is reached turn switch over press and hold down tactile button until the LED on back of switch blinks red twice. To adjust the up limit switch, press and hold the up tactile button until the LED on back of switch turns solid green. If you travel to far up you can press the down to move the screen downward. If you press and let go of either up or down button the motor will do a small jog in that direction for finer adjustment of screen. Once desired position is reached turn switch over press and hold up tactile button until the LED on back of switch blinks green twice. To test limit switch setting, press and release the up or down button on the wall switch to operate the screen. IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party control system is used. Therefore, it is advised to wire the switch or provide a 3-conductor connection that is accessible. DO NOT adjust the up limit travel any higher than the factory preset position or damage may occur. SCREEN ADJUSTMENT FOR 220V/240V SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL 1. Remove the cover plate from the 3-button wall switch and remove the switch from the junction box. To adjust the down limit switch, slide the 3-position switch to the down position. Press and hold the down button to run the screen down to the desired stop position. [. . . ] If it is necessary for the dealer to return the screen or part to Da-Lite, transportation expenses to and from Da-Lite are payable by the purchaser and Da-Lite is not responsible for damage in shipment. To protect yourself against damage or loss in transit, insure the product and prepay all transportation expenses. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY. Any implied warranties of fitness for use, or merchantability, that may be mandated by statute or rule of law are limited to the one (1) year warranty period. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DA-LITE TENSIONED COSMOPOLITAN ELECTROL




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DA-LITE TENSIONED COSMOPOLITAN ELECTROL will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.