User manual DA-LITE TENSIONED ADVANTAGE ELECTROL
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DA-LITE TENSIONED ADVANTAGE ELECTROL. We hope that this DA-LITE TENSIONED ADVANTAGE ELECTROL user guide will be useful to you.
You may also download the following manuals related to this product:
DA-LITE TENSIONED ADVANTAGE ELECTROL DATASHEET (101 ko)
DA-LITE TENSIONED ADVANTAGE ELECTROL DATASHEET (109 ko)
DA-LITE TENSIONED ADVANTAGE ELECTROL DATASHEET (134 ko)
DA-LITE TENSIONED ADVANTAGE ELECTROL DATASHEET (454 ko)
DA-LITE TENSIONED ADVANTAGE ELECTROL DATASHEET 2 (402 ko)
DA-LITE TENSIONED ADVANTAGE ELECTROL ANNEXE 428 (364 ko)
DA-LITE TENSIONED ADVANTAGE ELECTROL SPECIFICATION DATA (280 ko)
Manual abstract: user guide DA-LITE TENSIONED ADVANTAGE ELECTROL
Detailed instructions for use are in the User's Guide.
[. . . ] Toreducetheriskofelectricshock, donotdisassemblethisappliance. Contactanauthorized servicedealerwhenrepairworkisrequired. Incorrectreassemblycancauseelectricshockwhen theapplianceisusedsubsequently. Theuseofanaccessoryattachmentnotrecommendedbythemanufacturermaycauseariskof fire, electricshock, orinjurytopersons.
SAVE THESE INSTRUCTIONS
PRE-INSTALLATION
1. arefullyunpackcasefromshippingcarton. DONOTunpackfabricandrollerassemblyyet. [. . . ] Re-installaccessdoor. Procedureisreverseofremoval(step1).
1
ADVANTAGE® ELECTROL® INSTALLATION
6-1/16"
6-7/16"
VARIABLE POSITION MOUNTING BRACKET MOTOR END AUDIENCE SIDE
7-3/4" 8"
6-1/16"
ELECTRICAL JUNCTION BOX
3/8" THREADED ROD (NOT INCLUDED) ATTACHED TO MOUNTING BRACKET
6-3/8"
SELF-TRIMMING FLANGE 7-3/4"
FINISHED CEILING
SEE DETAIL A
3. 41"
3/8" THREADED ROD (NOT SUPPLIED)
6. 42"
7. 95"
HANGER BRACKET
7. 75"
DETAIL A
2
TENSIONED ADVANTAGE® ELECTROL® INSTALLATION FOR 120V SCREENS
120V WIRING DIAGRAM FOR STANDARD WALL SWITCH
JUNCTIONBOX LOCATEDIN LEFTENDCAP
WHITE RED BLACK GREEN
MOTOR
NOTE:
ASINGLESWITCHCANNOTBE USEDTOOPERATEMORETHAN ONESCREEN. CONTACTTHE FACTORYFORFURTHER INFORMATION.
WHITE RED(UP) BLACK(DOWN) SPDTSWITCHWITH CENTEROFF UP OFF DOWN THISSWITCHCANNOT BEUSEDWITHLVC. RED BLACK ACHOT120VAC60HZ1AMP BLACK/YELLOW AC(COMMON)
FIGURE3
UP
RJ-22 JACK
STO
P
UP DO (RE W CO N( D) (W MM BLA HIT ON CK ) E)
120V WIRING DIAGRAM WITH OPTIONAL BUILT-IN VIDEO PROJECTOR INTERFACE
CAUTION: THE PROJECTOR MUST BE TURNED OFF BEFORE CONNECTING THE TRIGGER WIRES TO THE PROJECTOR. U se2-conductor20-24gaugewiretoextendthelowvoltageconnectionfrom theprojector's5or12-voltscreentriggeroutputtothelengthrequiredtoreach theVPI. Whenextendingthelowvoltageconnectionfromtheprojector'sscreen triggeroutputpolaritydoesnotmatter. TheredandblackwiresfromtheVPIare interchangeable.
LED UPLIMIT TACTILE BUTTON RJ-22 INPUTS
RJ-22JACK RJ-22OUTPUT DRYCONTACTS
DOW
N
DOWN LIMIT TACTILE BUTTON BACKOF WALLSWITCH
RJ-45 JACK RJ-45 RECEPTACLE
DATA CABLE
FRONTOF WALLSWITCH
POWER WIRE BLACK RED
IMPORTANT NOTE: ThewallswitchisREQUIREDtomakeanylimitswitchadjustments, EVENifathirdpartycontrolsystemisused. Therefore, itisadvisedto wiretheswitchorprovidea3-conductorconnectionthatisaccessible.
5/12VOLTSCREEN TRIGGERONPROJECTOR
VPITRIGGER MODULE BLACK(HOT) WHITE(COMMON)
GREEN(GROUND) GROUNDMUSTBECONNECTED TOBUILDINGGROUND
POWER INPUT 120VAC / 60HZ
FIGURE4
3
TENSIONED ADVANTAGE® ELECTROL® INSTALLATION FOR 120V SCREENS
RJ-14 PIN-OUTS
(TAB IS FACING UP)
WHITE GREEN RED BLACK BUS (RP DATA) RQ DATA +5V GND
120V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL
LED RJ-22 JACK RJ-22 OUTPUT
RJ-22 PIN-OUTS
(TAB IS FACING UP)
+12V BUS (RP DATA) RQ DATA +5V GND RQ CLOCK BLUE YELLOW GREEN RED BLACK WHITE
Supplied RJ-14 cable
Standard RJ-22 can be used in place of RJ-14
UP DO (RED WN ) (BL M AC (W HIT K) E)
UP LIMIT TACTILE BUTTON RJ-22 JACK
RJ-22 INPUTS
RJ-45 PIN-OUTS
DRY CONTACTS (TAB IS FACING UP)
MANUAL 2 +12V BUS (RP DATA) RQ DATA +5V GND BROWN BLUE YELLOW GREEN RED BLACK ORANGE PURPLE
CO
UP
STO
P
DOW
N
DOWN LIMIT TACTILE BUTTON
RJ-45 JACK RJ-45 RECEPTACLE
RQ CLOCK
DATA CABLE
MANUAL 1
FRONT OF WALL SWITCH
BACK OF WALL SWITCH
POWER WIRE
IMPORTANT NOTE: ThewallswitchisREQUIREDtomakeanylimitswitch adjustments, EVENifathirdpartycontrolsystemis used. Therefore, itisadvisedtowiretheswitchor providea3-conductorconnectionthatisaccessible.
GREEN (GROUND) BLACK (HOT) WHITE (COMMON)
POWER INPUT 120VAC / 60HZ
GROUNDMUST BE CONNECTED TO BUILDING GROUND
FIGURE 5
4
TENSIONED ADVANTAGE® ELECTROL® INSTALLATION FOR 220/240V SCREENS
240V WIRING DIAGRAM WITH OPTIONAL BUILT-IN VIDEO PROJECTOR INTERFACE
BROWN(HOT) BLUE(COMMON)
GREEN/YELLOW(GROUND) BROWN(DOWN) BLUE(COMMON) BLACK(UP)
240 VOLT WIRING DIAGRAM FOR STANDARD WALL SWITCH: Da-Liteofferstwostylesof240voltwall switchesforstandardoperation. Pleasesee wiringdiagramincludedinwallswitchbox includedwithscreen.
240VOLTAC/50HZ POWERSOURCE
GREEN/YELLOW(GROUND)
FRONTOF WALLSWITCH
UP STOP DOWN
RED BLACK WHITE BACKOFWALL SWITCH
FIGURE 6
RED BLACK
5/12VOLTSCREEN TRIGGERONPROJECTOR
FIGURE 7
CAUTION: THE PROJECTOR MUST BE TURNED OFF BEFORE CONNECTING THE TRIGGER WIRES TO THE PROJECTOR. Use2-conductor20-24gaugewiretoextendthelowvoltageconnectionfromtheprojector's5or12-voltscreen triggeroutputtothelengthrequiredtoreachtheVPI. Whenextendingthelowvoltageconnectionfromthe projector'sscreentriggeroutput, besuretomaintaintheproperpolarity. TheredwirefromtheVPIisthe"signal" andtheblackwirefromtheVPIisthe"ground" . ConnectthewiresfromtheVPIthatarelabeled"LowVoltageConnection"totheendoftheextendedscreen triggerwiresabove.
!s
240V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL
BLUE (COMMON) BROWN (HOT) 240VAC 50HZ GREEN
OPTIONAL IR AND RF REMOTE CONTROL
LOW-VOLTAGE WALL SWITCH
UP DN UP GND +5V
MOTOR
RJ9
RJ9
STOP
DOWN
3-POSITION SWITCH
RJ9
GROUND TO CASE
UP +5V COM DN
GROUNDMUST BE CONNECTED TO BUILDING GROUND
GREEN FRONT BACK
SPLITTER DRY CONTACTS
ILT RJ9 PIN-OUTS
(TAB IS FACING UP)
IR or UP GND COMMON +5V DN or DATA
BLACK RED GREEN WHITE
IMPORTANT NOTE:ThewallswitchisREQUIREDtomakeanylimit switchadjustments, EVENifathirdpartycontrol systemisused. Therefore, itisadvisedtowirethe switchorprovidea4-conductorconnectionthatis accessible.
FIGURE 8
5
SCREEN ADJUSTMENT FOR 120V SCREENS WITHOUT BUILT-IN LOW VOLTAGE CONTROL
Surfacetravelisstoppedautomaticallyinthefullyopenedandclosedpositionsbylimitswitchesthatareproperly adjustedatDa-Lite. Shoulditbenecessarytoadjustformoreorlessdropofpicture, proceedinthefollowingmanner: Removetwoscrewstoremoveaccessdoor. henthescreenstops, turnthewhite"down"limitknob(Fig. 1)oneturncounterclockwise. Testbyraisingpicture W surfaceapproximatelytwofeet, thenloweragain. Repeatuntildesiredpicturesurfacepositionisattained. urnthewhite"down"limitknob T (Fig. 1)oneturnclockwise. Testby raisingpicturesurface approximatelytwofeet, thenlower again. Repeatuntildesiredpicture surfacepositionisattained.
WHITE ADJUSTMENT KNOB "DOWN"
MOTOR POWER CONNECTOR MOTOR
MOTOR MOUNT BRACKET
BLACK ADJUSTMENT KNOB "UP"
FIGURE 1
SCREEN ADJUSTMENT FOR 220/240V SCREENS WITHOUT BUILT-IN LOW VOLTAGE CONTROL
Surfacetravelisstoppedautomaticallyinthefullyopenedandclosedpositionsbylimitswitchesthatareproperly adjustedatDa-Lite. Shoulditbenecessarytoadjustformoreorlessdropofpicture, proceedinthefollowingmanner: NOTE:Useascrewdriveror5/32"Allenwrenchtomakeadjustments. henthescreenstops, turnthewhite "down"limitknob(Fig. 2)oneturncounterclockwise. Testbyraisingpicture W surfaceapproximatelytwofeet, thenloweragain. Repeatuntildesiredpicturesurfacepositionisattained. urnthewhite"down"limitknob T (Fig. 2)oneturnclockwise. Testby raisingpicturesurface approximatelytwofeet, thenlower again. Repeatuntildesiredpicture surfacepositionisattained.
MOTOR POWER CONNECTOR MOTOR
WHITE ADJUSTMENT KNOB "DOWN"
MOTOR MOUNT BRACKET
RED ADJUSTMENT KNOB "UP"
FIGURE 2
6
SCREEN ADJUSTMENT FOR 120V SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL OR VPI
1. Locatethewallswitchandremovethecoverplatefromthe3-buttonwallswitchandremovetheswitchfromthe junctionbox. Locatethetwotactilebuttonsonthebackoftheswitch. Theyaresquaresilverwithblackroundbuttons. See Figure4(VPI)orFigure5(LVC)fordiagram. Toadjustthedownlimitswitch, pressandholdthedowntactilebuttonuntiltheLEDonbackofswitchturnssolid red. Thiswillputthemotorinlimitsetmode. Turnthewallswitchoverandusethedownbuttononfrontof switch. Pressandholduntilthedesiredtravelpositionisreached. Ifyoutraveltofardownyoucanpresstheupto movethescreenupward. Ifyoupressandletgoofeitherupordownbuttonthemotorwilldoasmalljoginthat directionforfineradjustmentofscreen. Oncedesiredpositionisreachedturnswitchoverpressandholddown tactilebuttonuntiltheLEDonbackofswitchblinksredtwice. Thedownlimitisnowset. Toadjusttheuplimitswitch, pressandholdtheuptactilebuttonuntiltheLEDonbackofswitchturnssolidgreen. Thiswillputthemotorinlimitsetmode. Turnthewallswitchoverandusetheupbuttononfrontofswitch. Press andholduntilthedesiredtravelpositionisreached. Ifyoutraveltofarupyoucanpressthedowntomovethe screendownward. Ifyoupressandletgoofeitherupordownbuttonthemotorwilldoasmalljoginthatdirection forfineradjustmentofscreen. Oncedesiredpositionisreachedturnswitchoverpressandholduptactilebutton untiltheLEDonbackofswitchblinksgreentwice. Theuplimitisnowset. Totestlimitswitchsetting, pressandreleasetheupordownbuttononthewallswitchtooperatethescreen. [. . . ] IfitisnecessaryforthedealertoreturnthescreenorparttoDa-Lite, transportationexpenses toandfromDa-LitearepayablebythepurchaserandDa-Liteisnotresponsiblefordamagein shipment. Toprotectyourselfagainstdamageorlossintransit, insuretheproductandprepayall transportationexpenses. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY. Anyimplied warrantiesoffitnessforuse, ormerchantability, thatmaybemandatedbystatuteorruleoflaw arelimitedtotheone(1)yearwarrantyperiod. Thiswarrantygivesyouspecificlegalrights, and youmayalsohaveotherrights, whichvaryfromstate-to-state. NO LIABILITY IS ASSUMED FOR EXPENSES OR DAMAGES RESULTING FROM INTERRUPTION IN OPERATION OF EQUIPMENT, OR FOR INCIDENTAL, DIRECT, OR CONSEQUENTIAL DAMAGES OF ANY NATURE. IntheeventthatthereisadefectinmaterialsorworkmanshipofaDa-Liteproduct, youmay contactourSalesPartnersatPOBox137 , Warsaw, IN46581-0137 , (574)267-8101, (800)622-3737 . [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DA-LITE TENSIONED ADVANTAGE ELECTROL
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DA-LITE TENSIONED ADVANTAGE ELECTROL will begin.