User manual DA-LITE DESIGNER CONTOUR ELECTROL
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DA-LITE DESIGNER CONTOUR ELECTROL. We hope that this DA-LITE DESIGNER CONTOUR ELECTROL user guide will be useful to you.
You may also download the following manuals related to this product:
DA-LITE DESIGNER CONTOUR ELECTROL DATASHEET (122 ko)
DA-LITE DESIGNER CONTOUR ELECTROL DATASHEET (112 ko)
DA-LITE DESIGNER CONTOUR ELECTROL DATASHEET (146 ko)
DA-LITE DESIGNER CONTOUR ELECTROL SCHEMA (66 ko)
DA-LITE DESIGNER CONTOUR ELECTROL DATASHEET (279 ko)
DA-LITE DESIGNER CONTOUR ELECTROL DATASHEET 2 (175 ko)
DA-LITE DESIGNER CONTOUR ELECTROL SPECIFICATION DATA (124 ko)
DA-LITE DESIGNER CONTOUR ELECTROL DATASHEET WITH BUILT-IN INFRARED REMOTE CONTROL (274 ko)
Manual abstract: user guide DA-LITE DESIGNER CONTOUR ELECTROL
Detailed instructions for use are in the User's Guide.
[. . . ] The POWER In PRESENTATION PRODUCTS
DA-LITE SCREEN COMPANY, INC.
Instruction Book for
DESIGNER CONTOUR® ELECTROL®
3100 North Detroit Street Post Office Box 137 Warsaw, Indiana 46581-0137 Phone: 574-267-8101 800-622-3737 Fax: 574-267-7804 Toll Free Fax: 877-325-4832 www. da-lite. com e-mail: info@da-lite. com
IMPORTANT SAFETY INSTRUCTIONS
When using your video equipment, basic safety precautions should always be followed, including the following: 1. Position the cord so that it will not be tripped over, pulled, or contact hot surfaces. If an extension cord is necessary, a cord with a current rating at least equal to that of the appliance should be used. [. . . ] Remove the end cap on the right end of the case and insert the brackets into the case channel. Drill holes into the ceiling and attach screen with the appropriate fasteners for your ceiling. Do not remove the wall mount bracket, even if you are not using it for mounting. Be sure the ceiling has adequate reinforcement to attach a hook anchor. The top of the screen case has a channel that the ceiling hook brackets slide into. Remove the end cap on the right end of the case and insert the brackets into the case channel. The brackets can be attached anywhere within 12" of the end of the case. Attach an S-hook or similar fastener to the large center hole on the bracket.
2 WALL MOUNT BRACKET
4-1/4" CASE HOOK 5/16"
9/16"
4-5/8"
STOP SCREW
FIGURE 1
SET SCREWS (2) CEILING MOUNT HOLES
ENDCAP SCREWS (3) ENDCAP
FIGURE 2
SET SCREWS (2) HOOK MOUNT HOLE
ENDCAP SCREWS (3) ENDCAP
FIGURE 3
ELECTRICAL INSTALLATION
Internal wiring has been completed at the factory. Installer must route power to the wall switch and to the junction box located on the left end of the screen case. Standard installation is for a single 120VAC or 240VAC wall switch to control the screen. Wiring diagrams for the built-in VPI and low voltage control are included in these instructions. Refer to additional instructions for the external VPI, external low voltage control, SCB-100 and SCB-200. Refer to the appropriate wiring diagram for your screen.
120V WIRING DIAGRAM FOR STANDARD WALL SWITCH
JUNCTION BOX LOCATED IN LEFT ENDCAP
WHITE BLACK RED GREEN
MOTOR
GROUND TO CASE
WHITE BLACK (DOWN) RED (UP)
GROUNDMUST BE CONNECTED TO BUILDING GROUND AC (COMMON)
SPDT SWITCH WITH CENTER OFF BLACK UP OFF DOWN THIS SWITCH CAN NOT BE USED WITH LVC. RED
AC HOT 120VAC 60HZ 1 AMP BLACK/YELLOW
NOTE: A SINGLE SWITCH CANNOT BE USED TO OPERATE MORE THAN ONE SCREEN. CONTACT THE FACTORY FOR FURTHER INFORMATION.
240 VOLT WIRING DIAGRAM FOR STANDARD WALL SWITCH:
Da-Lite offers two styles of 240 volt wall switches for standard operation. Please see wiring diagram included in wall switch box included with screen.
3
ELECTRICAL INSTALLATION
120V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL
RED BLACK
MOTOR
WHITE (COMMON)
GROUND TO CASE EYE AUX
BLACK WHITE RED
UP
STOP
DOWN
120VAC 60HZ
WHITE (COMMON) BLACK (HOT) GREEN
LOW-VOLTAGE WALL SWITCH OPTIONAL RF OR IR REMOTE CONNECTOR
GROUNDMUST BE CONNECTED TO BUILDING GROUND
240V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL
BLACK (UP) BROWN (DOWN)
MOTOR
BLUE (COMMON)
OPTIONAL RF OR IR REMOTE CONNECTOR
GROUND TO CASE
AUX EYE
BLACK WHITE RED
UP
STOP
BLACK
DOWN
240VAC 50HZ
BLUE (COMMON) BROWN (HOT) BLACK
LOW-VOLTAGE WALL SWITCH
GROUNDMUST BE CONNECTED TO BUILDING GROUND
GREEN
4
SCREEN ADJUSTMENT
Screen travel is stopped automatically in the down and up positions by the limit switches that are preset at the factory. [. . . ] "Up" Position Check for power across red and white leads.
(b) Blown fuse. (d) No power to operating switch or junction.
Power at junction box (e) Thermal overload tripped. Call for information (a) Replace motor assembly.
(a) Defective brake.
(a) Replace motor assembly.
RESTORING LOST ROLLER WRAP
1. [. . . ]