User manual DA-LITE COSMOPOLITAN ELECTROL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DA-LITE COSMOPOLITAN ELECTROL. We hope that this DA-LITE COSMOPOLITAN ELECTROL user guide will be useful to you.


DA-LITE COSMOPOLITAN ELECTROL : Download the complete user guide (406 Ko)

You may also download the following manuals related to this product:

   DA-LITE COSMOPOLITAN ELECTROL DATASHEET (116 ko)
   DA-LITE COSMOPOLITAN ELECTROL DATASHEET (117 ko)
   DA-LITE COSMOPOLITAN ELECTROL DATASHEET (154 ko)
   DA-LITE COSMOPOLITAN ELECTROL ASSEMBLY (287 ko)
   DA-LITE COSMOPOLITAN ELECTROL MANUAL 2 (422 ko)
   DA-LITE COSMOPOLITAN ELECTROL DATASHEET (237 ko)
   DA-LITE COSMOPOLITAN ELECTROL ANNEXE 857 (407 ko)
   DA-LITE COSMOPOLITAN ELECTROL CEILING TRIM KIT (282 ko)
   DA-LITE COSMOPOLITAN ELECTROL SPECIFICATION DATA (184 ko)
   DA-LITE COSMOPOLITAN ELECTROL FOR SIZES UP TO 9X12 (408 ko)

Manual abstract: user guide DA-LITE COSMOPOLITAN ELECTROL

Detailed instructions for use are in the User's Guide.

[. . . ] OFF . NOTE: Must be installed in accordance with the requirements of the Local Building Codes, the Canadian Electrical Code (CEC), CAN/ CSA C22. 1 and the National Electric Code (NEC), NFPA 70. 1 COSMOPOLITAN® ELECTROL® INSTALLATION 3/4" DIAMETER HOLE FOR WALL INSTALLATION MOTOR END Overall length A=fabric width + 8". Length B is the distance between wall mounting holes at back of end caps and is the fabric width + 6-1/2". A B 4" FABRIC HEIGHT x WIDTH AS ORDERED, UP TO 12 FEET x 12 FEET. 4" FIGURE 2 423/32" 5 /32" 129/32" /8" DIAMETER FOR CEILING INSTALLATION 3 63/32" 57/8" ENCLOSURE COVER 1 /16" 3 /8" DIAMETER KNOCK OUT 7 7 /8" DIAMETER OPENING FOR ELECTRICAL FITTINGS PICTURE SURFACE 2 COSMOPOLITAN® ELECTROL® INSTALLATION WIRING ENCLOSURE COVER 120V WIRING DIAGRAM TO JUNCTION BOX, MOUNTED IN SCREEN CASE, IN WHICH INTERNAL WIRING TERMINATES IN WHITE, BLACK AND RED LEADS DOWN BLACK UP RED COMMON WHITE DOWN WHITE LIMIT SWITCH ADJUSTMENT BLACK ROCKER SWITCH UP OFF DOWN WHITE RED BLACK WITH YELLOW SIDE VIEW OF SWITCH AND BOX OPERATING SWITCH AND PLATE FURNISHED WITH SCREEN. (SPDT WITH CENTER OFF) IN MULTIPLE CONTROL INSTALLATIONS THIS SWITCH IS REPLACED BY THE LOW VOLTAGE CONTROL, OPERATED FROM PUSH BUTTON STATIONS. AC COMMON AC HOT 120 V. [. . . ] TO INCREASE SCREEN DROP: Turn the white limit switch screw counterclockwise to increase the amount of screen drop. If the screen does not drop enough, raise the screen about one foot and adjust the limit switch again. s SCREEN ADJUSTMENT FOR 120V SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL OR VPI 1. Locate the wall switch and remove the cover plate from the 3-button wall switch and remove the switch from the junction box. To adjust the down limit switch, press and hold the down tactile button until the LED on back of switch turns solid red. If you travel to far down you can press the up to move the screen upward. If you press and let go of either up or down button the motor will do a small jog in that direction for finer adjustment of screen. Once desired position is reached turn switch over press and hold down tactile button until the LED on back of switch blinks red twice. To adjust the up limit switch, press and hold the up tactile button until the LED on back of switch turns solid green. If you travel to far up you can press the down to move the screen downward. If you press and let go of either up or down button the motor will do a small jog in that direction for finer adjustment of screen. Once desired position is reached turn switch over press and hold up tactile button until the LED on back of switch blinks green twice. To test limit switch setting, press and release the up or down button on the wall switch to operate the screen. IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party control system is used. Therefore, it is advised to wire the switch or provide a 3-conductor connection that is accessible. SCREEN ADJUSTMENT FOR 220V/240V SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL 1. Remove the cover plate from the 3-button wall switch and remove the switch from the junction box. To adjust the down limit switch, slide the 3-position switch to the down position. Press and hold the down button to run the screen down to the desired stop position. [. . . ] To protect yourself against damage or loss in transit, insure the product and prepay all transportation expenses. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY. Any implied warranties of fitness for use, or merchantability, that may be mandated by statute or rule of law are limited to the one (1) year warranty period. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DA-LITE COSMOPOLITAN ELECTROL




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DA-LITE COSMOPOLITAN ELECTROL will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.