[. . . ] Contact the factory for further information.
THIS SWITCH CANNOT BE USED WITH LVC.
FIGURE 3
240 VOLT WIRING DIAGRAM FOR STANDARD WALL SWITCH: Da-Lite offers two styles of 240 volt wall switches for standard operation. Please see wiring diagram included in wall switch box included with screen.
120V WIRING DIAGRAM WITH OPTIONAL BUILT-IN VIDEO PROJECTOR INTERFACE
CAUTION: THE PROJECTOR MUST BE TURNED OFF BEFORE CONNECTING THE TRIGGER WIRES TO THE PROJECTOR. Use 2-conductor 20-24 gauge wire to extend the low voltage connection from the projector's 5 or 12-volt screen trigger output to the length required to reach the VPI. When extending the low voltage connection from the projector's screen trigger output polarity does not matter. [. . . ] The red and black wires from the VPI are interchangeable.
LED UP LIMIT TACTILE BUTTON
P
RJ-22 JACK RJ-22 INPUTS RJ-22 JACK
BUS 5V COM
RJ-22 OUTPUT
UP DOWN COMMON BUS 5V
DRY CONTACTS BUS
UP
STO
DOW
RJ-45 RECEPTACLE RJ-45 JACK DATA CABLE
N
DOWN LIMIT TACTILE BUTTON FRONT OF WALL SWITCH
BUS
BACK OF WALL SWITCH POWER WIRE BLACK RED
IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party control system is used. Therefore, it is advised to wire the switch or provide a 3-conductor connection that is accessible. 3-conductor 20-24 gauge wire can be used in place of the supplied RJ-14 cable to connect the wall switch. Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board.
5/12 VOLT SCREEN TRIGGER ON PROJECTOR
VPI TRIGGER MODULE BLACK (HOT) WHITE (COMMON)
GREEN (GROUND) GROUNDMUST BE CONNECTED TO BUILDING GROUND
POWER INPUT 120VAC / 60HZ
FIGURE 4
3
COSMOPOLITAN® ELECTROL® INSTALLATION
120V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL
RJ-22 JACK LED UP LIMIT TACTILE BUTTON
UP
RJ-14 PIN-OUTS
(TAB IS FACING UP)
WHITE GREEN RED BLACK BUS (RP DATA) RQ DATA +5V GND
RJ-22 PIN-OUTS
(TAB IS FACING UP)
+12V BUS (RP DATA) RQ DATA +5V GND RQ CLOCK BLUE YELLOW GREEN RED BLACK WHITE
Supplied RJ-14 cable RJ-22 OUTPUT
Standard RJ-22 can be used in place of RJ-14
RJ-22 INPUTS RJ-22 JACK
UP DOWN COMMON BUS 5V RJ-45 RECEPTACLE
RJ-45 PIN-OUTS
DRY CONTACTS BUS (TAB IS FACING UP)
MANUAL 2 +12V BUS (RP DATA) RQ DATA +5V GND RQ CLOCK BROWN BLUE YELLOW GREEN RED BLACK ORANGE PURPLE
STO
P
DOW
RJ-45 JACK
5V COM BUS
N
DOWN LIMIT TACTILE BUTTON
BUS
DATA CABLE
MANUAL 1
FRONT OF WALL SWITCH
BACK OF WALL SWITCH
POWER WIRE
3-conductor 20-24 gauge wire can be used in place of the supplied RJ-14 cable to connect the wall switch. Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board. IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party control system is used. Therefore, it is advised to wire the switch or provide a 3-conductor connection that is accessible.
GREEN (GROUND) BLACK (HOT) WHITE (COMMON)
POWER INPUT 120VAC / 60HZ
GROUNDMUST BE CONNECTED TO BUILDING GROUND
FIGURE 5
240V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL
BLUE (COMMON) BROWN (HOT)
OPTIONAL IR AND RF REMOTE CONTROL
CONNECT SUPPLIED RJ9 CABLE TO SPLITTER AND SWITCH, OR USE 4 CABLE CONDUCTOR TO CONNECT TO SCREW TERMINALS.
LOW-VOLTAGE WALL SWITCH
UP DN UP
GND +5V
240VAC 50HZ
MOTOR
RJ9
RJ9
STOP
GREEN
DOWN 3-POSITION SWITCH RJ9
GROUND TO CASE
UP +5V COM DN
GROUNDMUST BE CONNECTED TO BUILDING GROUND
GREEN FRONT BACK
SPLITTER DRY CONTACTS
ILT RJ9 PIN-OUTS
(TAB IS FACING UP)
IR or UP GND COMMON +5V DN or DATA
BLACK RED GREEN WHITE
IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party control system is used. Therefore, it is advised to wire the switch or provide a 4-conductor connection that is accessible.
FIGURE 6
4
SCREEN ADJUSTMENT FOR SCREENS WITHOUT A BUILT-IN LOW VOLTAGE CONTROL
Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly adjusted at DA-LITE. Should it be necessary to adjust for more or less picture drop (viewing area), proceed in the following manner: NOTE: Use a screwdriver or 5/32" Allen wrench to make adjustments. Therefore, it is advised to wire the switch or provide a 3-conductor connection that is accessible.
SCREEN ADJUSTMENT FOR 220V/240V SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL
1. Remove the cover plate from the 3-button wall switch and remove the switch from the junction box. To adjust the down limit switch, slide the 3-position switch to the down position. Press and hold the down button to run the screen down to the desired stop position. When the screen is in the desired down position, slide the 3-position switch to the off (center) position. To adjust the up limit switch, slide the 3-position switch to the up position. Press and hold the up button to run the screen up to the desired stop position. When the screen is in the desired up position, slide the 3-position switch to the off (center) position. To test limit switch setting, make sure the 3-position switch is in the off (center) position. [. . . ] When the screen is in the desired up position, slide the 3-position switch to the off (center) position. To test limit switch setting, make sure the 3-position switch is in the off (center) position. Press and release the up or down button on the wall switch to operate the screen. NOTE: If stop button is pressed, the wall switch will reverse direction. [. . . ]