User manual DA-LITE CM-USC-4747 PARTS LIST

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DA-LITE CM-USC-4747. We hope that this DA-LITE CM-USC-4747 user guide will be useful to you.


DA-LITE CM-USC-4747 PARTS LIST: Download the complete user guide (18 Ko)

Manual abstract: user guide DA-LITE CM-USC-4747PARTS LIST

Detailed instructions for use are in the User's Guide.

[. . . ] Contact the factory for further information. THIS SWITCH CANNOT BE USED WITH LVC. FIGURE 3 240 VOLT WIRING DIAGRAM FOR STANDARD WALL SWITCH: Da-Lite offers two styles of 240 volt wall switches for standard operation. Please see wiring diagram included in wall switch box included with screen. 120V WIRING DIAGRAM WITH OPTIONAL BUILT-IN VIDEO PROJECTOR INTERFACE CAUTION: THE PROJECTOR MUST BE TURNED OFF BEFORE CONNECTING THE TRIGGER WIRES TO THE PROJECTOR. Use 2-conductor 20-24 gauge wire to extend the low voltage connection from the projector's 5 or 12-volt screen trigger output to the length required to reach the VPI. When extending the low voltage connection from the projector's screen trigger output polarity does not matter. [. . . ] The red and black wires from the VPI are interchangeable. LED UP LIMIT TACTILE BUTTON P RJ-22 JACK RJ-22 INPUTS RJ-22 JACK BUS 5V COM RJ-22 OUTPUT UP DOWN COMMON BUS 5V DRY CONTACTS BUS UP STO DOW RJ-45 RECEPTACLE RJ-45 JACK DATA CABLE N DOWN LIMIT TACTILE BUTTON FRONT OF WALL SWITCH BUS BACK OF WALL SWITCH POWER WIRE BLACK RED IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party control system is used. Therefore, it is advised to wire the switch or provide a 3-conductor connection that is accessible. 3-conductor 20-24 gauge wire can be used in place of the supplied RJ-14 cable to connect the wall switch. Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board. 5/12 VOLT SCREEN TRIGGER ON PROJECTOR VPI TRIGGER MODULE BLACK (HOT) WHITE (COMMON) GREEN (GROUND) GROUND­MUST BE CONNECTED TO BUILDING GROUND POWER INPUT 120VAC / 60HZ FIGURE 4 3 COSMOPOLITAN® ELECTROL® INSTALLATION 120V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL RJ-22 JACK LED UP LIMIT TACTILE BUTTON UP RJ-14 PIN-OUTS (TAB IS FACING UP) WHITE GREEN RED BLACK BUS (RP DATA) RQ DATA +5V GND RJ-22 PIN-OUTS (TAB IS FACING UP) +12V BUS (RP DATA) RQ DATA +5V GND RQ CLOCK BLUE YELLOW GREEN RED BLACK WHITE Supplied RJ-14 cable RJ-22 OUTPUT Standard RJ-22 can be used in place of RJ-14 RJ-22 INPUTS RJ-22 JACK UP DOWN COMMON BUS 5V RJ-45 RECEPTACLE RJ-45 PIN-OUTS DRY CONTACTS BUS (TAB IS FACING UP) MANUAL 2 +12V BUS (RP DATA) RQ DATA +5V GND RQ CLOCK BROWN BLUE YELLOW GREEN RED BLACK ORANGE PURPLE STO P DOW RJ-45 JACK 5V COM BUS N DOWN LIMIT TACTILE BUTTON BUS DATA CABLE MANUAL 1 FRONT OF WALL SWITCH BACK OF WALL SWITCH POWER WIRE 3-conductor 20-24 gauge wire can be used in place of the supplied RJ-14 cable to connect the wall switch. Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board. IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party control system is used. Therefore, it is advised to wire the switch or provide a 3-conductor connection that is accessible. GREEN (GROUND) BLACK (HOT) WHITE (COMMON) POWER INPUT 120VAC / 60HZ GROUND­MUST BE CONNECTED TO BUILDING GROUND FIGURE 5 240V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL BLUE (COMMON) BROWN (HOT) OPTIONAL IR AND RF REMOTE CONTROL CONNECT SUPPLIED RJ9 CABLE TO SPLITTER AND SWITCH, OR USE 4 CABLE CONDUCTOR TO CONNECT TO SCREW TERMINALS. LOW-VOLTAGE WALL SWITCH UP DN UP GND +5V 240VAC 50HZ MOTOR RJ9 RJ9 STOP GREEN DOWN 3-POSITION SWITCH RJ9 GROUND TO CASE UP +5V COM DN GROUND­MUST BE CONNECTED TO BUILDING GROUND GREEN FRONT BACK SPLITTER DRY CONTACTS ILT RJ9 PIN-OUTS (TAB IS FACING UP) IR or UP GND COMMON +5V DN or DATA BLACK RED GREEN WHITE IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party control system is used. Therefore, it is advised to wire the switch or provide a 4-conductor connection that is accessible. FIGURE 6 4 SCREEN ADJUSTMENT FOR SCREENS WITHOUT A BUILT-IN LOW VOLTAGE CONTROL Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly adjusted at DA-LITE. Should it be necessary to adjust for more or less picture drop (viewing area), proceed in the following manner: NOTE: Use a screwdriver or 5/32" Allen wrench to make adjustments. Therefore, it is advised to wire the switch or provide a 3-conductor connection that is accessible. SCREEN ADJUSTMENT FOR 220V/240V SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL 1. Remove the cover plate from the 3-button wall switch and remove the switch from the junction box. To adjust the down limit switch, slide the 3-position switch to the down position. Press and hold the down button to run the screen down to the desired stop position. When the screen is in the desired down position, slide the 3-position switch to the off (center) position. To adjust the up limit switch, slide the 3-position switch to the up position. Press and hold the up button to run the screen up to the desired stop position. When the screen is in the desired up position, slide the 3-position switch to the off (center) position. To test limit switch setting, make sure the 3-position switch is in the off (center) position. [. . . ] When the screen is in the desired up position, slide the 3-position switch to the off (center) position. To test limit switch setting, make sure the 3-position switch is in the off (center) position. Press and release the up or down button on the wall switch to operate the screen. NOTE: If stop button is pressed, the wall switch will reverse direction. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DA-LITE CM-USC-4747




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DA-LITE CM-USC-4747 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.