User manual DA-LITE ASCENDER ELECTROL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DA-LITE ASCENDER ELECTROL. We hope that this DA-LITE ASCENDER ELECTROL user guide will be useful to you.


DA-LITE ASCENDER ELECTROL : Download the complete user guide (336 Ko)

You may also download the following manuals related to this product:

   DA-LITE ASCENDER ELECTROL DATASHEET (90 ko)
   DA-LITE ASCENDER ELECTROL DATASHEET (81 ko)
   DA-LITE ASCENDER ELECTROL DATASHEET (114 ko)
   DA-LITE ASCENDER ELECTROL DATASHEET (260 ko)

Manual abstract: user guide DA-LITE ASCENDER ELECTROL

Detailed instructions for use are in the User's Guide.

[. . . ] Toreducetheriskofelectricshock, donotdisassemblethisappliance. Contactanauthorizedservicedealer whenrepairworkisrequired. Incorrectreassemblycancauseelectricshockwhentheapplianceisused subsequently. Theuseofanaccessoryattachmentnotrecommendedbythemanufacturermaycauseariskoffire, electric shock, orinjurytopersons. SAVE THESE INSTRUCTIONS PRE-INSTALLATION 1. Removethewhiteshippingbraces(mountedattheendofthearmstothebackofthecase). Refertothechartbelowforminimumoverheadclearancerequiredtoraisethescreen. [. . . ] Connectthewirefromtheswitchtothewirelabeled"wallswitch" . Refertofigure3. CAUTION: Never apply voltage to the wall switch lead or the LVC will be damaged. Control Panel AcontrolpanelmaybeconnectedtotheLVCbyusingthewallswitchwirelead. Thecontrolpanelmustprovidea momentary, drycontactclosureofatleast1/2second. Use2-conductor20-24gaugewiretoconnectthecontrolpaneltothewallswitchlead. Amomentaryclosurewhenthescreenisfullyextendedwillbea"down"command. Amomentaryclosurewhilethescreenisinmotionwillbea"stop"command. CAUTION: Never apply voltage to the wall switch lead or the LVC will be damaged. Refertofigure3forelectricalconnections. Wiringdesignatedasexternalistobecompletedbyinstaller conformingtolocalandnationalcodes. NOTE: Must be installed in accordance with the requirements of the Local Building Codes, the Canadian Electrical Code (CEC), CAN/CSA C22. 1 and the National Electric Code (NEC), NFPA 70. An appropriate disconnect device shall be provided as part of the building installation. Use14-18gaugewiretoconnectpowertotheLVCwireslabeled"ACpowerinput" . Refertofigure3. Routethereceiverwirethroughtheroundplasticbushingandplugitintotheonboardsocketmarked"EYE" . Refer tofigure3. Routethereceiverwirethroughtheroundplasticbushingandplugitintotheonboardsocketmarked"EYE" . Refer tofigure3. 3 ASCENDER ELECTROL® INSTALLATION 120V WIRING DIAGRAM WHITE (COMMON) SINGE PULL, SINGLE THROW MOMENTARY CONTACT SWITCH UP / STOP / DOWN GREEN (GROUND) BLACK (UP) RED (DOWN) WHITE (COMMON) OPTIONAL IR OR RF CONNECTION BLACK OFF WHITE (COMMON) BLACK (HOT) MOTOR GREEN (GROUND) NOT USED WHITE (COMMON) BLACK NOT USED POWER INPUT 120 VAC / 60 HZ FIGURE 3 DOOR MICROSWITCH 240V WIRING DIAGRAM WHITE (COMMON) SINGE PULL, SINGLE THROW MOMENTARY CONTACT SWITCH UP / STOP / DOWN GREEN / YELLOW (GROUND) BROWN (UP) BLACK (DOWN) BLUE (COMMON) OPTIONAL IR OR RF CONNECTION BLACK OFF BLUE (COMMON) BROWN (HOT) MOTOR GREEN / YELLOW (GROUND) NOT USED WHITE (COMMON) BLACK NOT USED POWER INPUT 240 VAC / 50 HZ FIGURE 3 DOOR MICROSWITCH 4 SCREEN ADJUSTMENT Thescreenstoppositionsarepresetatthefactory. Shoulditbenecessarytoadjustformoreorlesstravelproceedas follows. Refertofigure4. Turnthewhitelimitadjustercounterclockwiseone-quarterturnatatime. Runthescreendownaboutonefootand thenbackuptotestthestopposition. Repeatuntilthedesiredpositionisset. Adjusting too high may cause the arms to lock and not retract properly. There must be at least 1-1/2 wraps of fabric on the roller at all times. Turnwhitelimitadjusterclockwiseone-quarterturnatatime. Runthescreenuptotestthestopposition. Lower thescreenaboutonefootandturnlimitadjusteragain. Repeatuntilthedesiredpositionisset. Raisethescreenaboutonefootandstop. Turntheredlimitadjustercounterclockwiseone-quarterturnto increasethedowntravel. Turntheredlimitadjusterclockwiseone-quarterturnatatimetodecreasetheamountofdowntravel. Runthe screendowntotestthestopposition. Repeatuntilthedesiredpositionisset. WHITE LIMIT ADJUSTER RED LIMIT ADJUSTER FIGURE 4 KEYSTONE ADJUSTMENT TheAscenderscreencanbeadjustedtoreducekeystoningofthevideoimage. NOTE: Make sure that the screen surface does not rub against the edge of the case. ADJUSTING NUT FIGURE 5 LOCK NUTS 5 TROUBLESHOOTING SYMPTOM 1. [. . . ] Da-Lite'ssoleobligationunderthiswarrantyshallbetorepairortoreplace(atDa-Lite'soption) thedefectivepartofthemerchandise. ReturnsforserviceshouldbemadetoyourDa-Litedealer. IfitisnecessaryforthedealertoreturnthescreenorparttoDa-Lite, transportationexpenses toandfromDa-LitearepayablebythepurchaserandDa-Liteisnotresponsiblefordamagein shipment. Toprotectyourselfagainstdamageorlossintransit, insuretheproductandprepayall transportationexpenses. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY. Anyimplied warrantiesoffitnessforuse, ormerchantability, thatmaybemandatedbystatuteorruleoflaw arelimitedtotheone(1)yearwarrantyperiod. Thiswarrantygivesyouspecificlegalrights, and youmayalsohaveotherrights, whichvaryfromstate-to-state. NO LIABILITY IS ASSUMED FOR EXPENSES OR DAMAGES RESULTING FROM INTERRUPTION IN OPERATION OF EQUIPMENT, OR FOR INCIDENTAL, DIRECT, OR CONSEQUENTIAL DAMAGES OF ANY NATURE. IntheeventthatthereisadefectinmaterialsorworkmanshipofaDa-Liteproduct, youmay contactourSalesPartnersatPOBox137 , Warsaw, IN46581-0137 , (574)267-8101, (800)622-3737 . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DA-LITE ASCENDER ELECTROL




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DA-LITE ASCENDER ELECTROL will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.