User manual CORBERO SC400

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CORBERO SC400. We hope that this CORBERO SC400 user guide will be useful to you.


CORBERO SC400 : Download the complete user guide (450 Ko)

Manual abstract: user guide CORBERO SC400

Detailed instructions for use are in the User's Guide.

[. . . ] Check your appliance each time before use. ENVIRONMENT PROTECTION I USE I I The materials used on this appliance marked with the symbol are recyclable. This means that they can be recycled by disposing of them properly in appropriate collection containers. If you take your appliance to a refuse disposal site, cut off the power cable flush with the appliance to avoid the danger of the appliance being re-used, and disable the door catch to prevent children becoming trapped inside. I I I I I Always unplug the appliance after use. The higher the spin speed, the lower the electricity consumption and the shorter the drying times. [. . . ] The tumble dryer must be installed in a clean place, where dirt does not build up. Make sure there are no obstructing items or material near the air-intake louvres provided at the back (e. g. To keep vibration and noise to a minimum when the dryer is in use, it should be placed on a firm, level surface. Once in its permanent operating position, check that the dryer is absolutely level with the aid of a spirit level. If it is not, raise or lower the two adjustable feet at the front of the machine until it is. Do not restrict the floor clearance through deep-pile carpets, strips of wood or similar. This might cause heat build-up which would interfere with the operation of the appliance. Important When operating the tumble dryer, the room temperature must not exceed 35°C, as it may affect the performance of the appliance. P0046 Fitting the vent hose To simplify the installation, there is a choice of vent outlets: one at the back, the others in the left and right-hand side. Connect the hose to whichever is the more convenient by pulling the ring nut (A) from the vent outlet at the back, screwing it on to the hose and pushing it firmly back into place. The unused vents should now be sealed with the special snap covers provided. A P1028 A P1027 5 ENGLISH Advice: If the hose is long and the room temperature low, the moisture might condense to water inside the hose. To prevent this water from Iying in the hose or flowing back into the tumble dryer, it is advisable to drill a small hole (dia. This starts 9 minutes before the end of drying to prevent any creasing or crumpling of fabrics. 8 Electronic Controlled Programmes These operate by means of dampness sensors. All you have to do is to set the selector dial for the programme required A, B, C or D and the laundry will be dried to the selected degree of dryness. The following are the degrees of final drying which can be obtained with electronic control: Extra Dry Ideal for bathrobes, bath towels etc. Store Dry Suitable for items which you want to put away without ironing, for example towels and non-iron fabrics. Iron Dry Suitable for items which need ironing. I I I I Time Controlled Programmes You can select a time up to 90 mins. to finish off drying, if necessary, or to use your tumble dryer independently of the electronic control system. When selecting a short drying time, remember that during the last 9 mins. of operation, the heat is cut off in order to carry out a cooling phase. button . Synthetics (store dry) Suitable for delicate articles which do not need ironing. 9 ENGLISH Drying programmes Electronic Controlled Programmes Type of laundry Degree of drying required Extra dry Cotton & linen Store dry Iron dry Synthetics Store dry 2. 5 kg 5. 0 kg Quantity Selector dial setting A B (*) C (*) D (*) (*) According to CEI 1121 standards. Time Controlled Programmes - Cotton and Linen Degree of drying required Degree of spin given Quantity 5 kg 2 kg 5 kg 2 kg 800-900 rpm Iron dry 1000-1200 rpm 5 kg 2 kg 5 kg 2 kg Selector dial setting mins 75-90 60-75 60-75 45-60 60-75 45-60 45-60 30-45 800-900 rpm Store dry 1000-1200 rpm Time Controlled Programmes - Synthetics: switch on pushbutton Degree of drying required Degree of spin given Quantity 2. 5 kg Store dry Short spin at 650 rpm 1. 0 kg 0. 5 kg Never overfill the drum (do not load large quilts, for example). The laundry must be suitably spun in your washing machine before being placed in the tumble dryer (500rpm minimum). Sheet 700 - 1000 g Tablecloth 400 - 500 g Kitchen towel 70 - 120 g Table napkin 50 - 100 g Towelling hand towel 150 - 250 g Bathrobe 1000 - 1500 g Man's shirt 200 - 300 g Pillowcase 100 - 200 g Man's pyjamas 400 - 500 g Ladies' nightdress 200 - 250 g Never tumble dry the following: Particularly delicate items such as net curtains, woollen, silk, fabrics with metal trim, nylon tights, bulky materials such as anoraks, blankets, eiderdowns, sleeping bags, feather quilts and any items containing rubber foam or materials similar to rubber foam. [. . . ] If individual items are still damp after drying, set a brief post-drying time, but at least 20 minutes. collars, pockets, etc. ). I I I I I I I Close pillowcases and covers with fasteners to prevent small laundry items getting tangled inside them. Avoid drying dark clothes with light coloured fluffy items such as towels as they could attract the fluff. shirts, should be briefly pre-spun before drying (depending on crease resistance approx. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CORBERO SC400




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CORBERO SC400 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.