[. . . ] Logic 3
OWNER'S MANUAL
APT
INDUSTRIAL DUT Y COMMERCIAL DOOR OPERATOR
This Operator Features the Enhanced
IN
T ENA N
C
E
M A
E
R
T SYS
T
The Maintenance Alert SystemTM allows the installer to set an internal Maintenance Cycle Counter. The Logic 3 operator incorporates a self-diagnostic feature built into the (MAS) Maintenance Alert System LED. An LED on the 3-button station will signal when the set number of cycles/months is reached or when the operator requires immediate service.
Radio Receiver Built on Board
2 YEAR WARRANTY
315MHz
Serial # Box Installation Date NOT FOR RESIDENTIAL USE
E
PAT E N T P E N D I N G
M
A
L
TABLE OF CONTENTS
SPECIFICATIONS
Carton Inventory . . 8
AUTOMATICALLY LEARNED PROGRAMMING
Auxiliary Reversal System/RPM Sensor . [. . . ] Compatible with 3-Button Station, 1-Button Station, 1 & 3 Button Remote Control.
17
PROGRAMMING
Built in 3-channel, 315MHz radio receiver allows you to add as many as 23 Security® remotes or dip switch remote controls.
PROGRAMMING REMOTES
STANDARD SINGLE BUTTON REMOTE 1. To enter programming press and release the RADIO button on the logic board (LED will light). Press and hold the remote button until the LED flashes rapidly, then release remote button. The programming mode is exited if no activity is performed within 30 seconds. NOTE: Single button remote is not supported with D1 and E2 failsafe wiring modes. NOTE: Requires self-monitoring photo eyes when using constant pressure to close (wiring C2, D1 and E2 ). SINGLE BUTTON CONTROL (SBC) REMOTE This function programs a remote as a wireless single button control. In C2 mode, operation is OPEN / STOP/ Constant pressure to CLOSE / STOP on release. In T and TS modes, operation is OPEN / STOP / CLOSE / REVERSE / STOP and Timer to Close start/refresh. In FSTS mode, operation is OPEN with Timer to Close start/refresh only bypassing all up mid stops. Momentary and constant pressure commands are processed in this function.
OPERATION MODE B2 C2 D1 E2 T, TS FSTS OPEN STOP CLOSE Reverse Constant Pressure Timer To Close
WARNING
To prevent possible SERIOUS INJURY or DEATH, install reversing sensors when the 3-button control station is out of sight of the door or ANY other control (automatic or manual) is used. Reversing devices are recommended for ALL installations.
CAUTION
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Ø14LGØ65 P4
E1
R29
C11 D3Ø2 X1 U1
K3
RADIO
D16 P7
OLS
D25
MID
D24
1. Press and release the RADIO button on the logic board (LED will light). Press and release the SBC externally wired button or TIMER on the logic board (LED flashes rapidly and then remains on solid). Press and release the RADIO button on the logic board (LED flashes rapidly and then turns off). The programming mode is exited if no activity is performed within 30 seconds. ERASING REMOTES Press and hold the RADIO button on the logic board until the RADIO LED flashes rapidly (approximately 5 seconds). All remotes will be erased.
SLS
D26
CLS MRT MID
D27
TIM
RADIO
1
D36
2
RELAY
C77 D35 C73
RELAY
E2 D1
L1
LiftM
ast er
C2
C71 L5
B2
FAILSAFE
P6
18
MOTOR
REV
C54
C78
®
PROGRAMMING
Your 315MHz Security® or dip switch remote control can be programmed to operate as a 3-button wireless control station: the large button will open the door, the middle button will close the door, and the third button will stop the door's movement. To enter programming press the RADIO button on the logic board (the RADIO LED will light). To program the OPEN button to a remote control press the OPEN button on the logic board. The RADIO LED on the logic board will flash, this confirms that the remote control has been programmed. [. . . ] There may be more than one error present, but only the highest priority will flash. All errors self-correct when the corrective action is taken and a reset is not needed. 27
TROUBLESHOOTING RADIO FUNCTIONALITY
The error codes will display at the radio LED. NOTE: Radio receiver is compatible with 315MHz remotes
ERROR CODE
R1
SYMPTOM
No response from the remote
DISPLAY
Quick Flash
POSSIBLE PROBLEM
Unlearned remote A user tries to use a remote, but the RADIO LED only flashes briefly and there is no response from the operator. [. . . ]