User manual CASIO GRAPH 90 E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CASIO GRAPH 90 E. We hope that this CASIO GRAPH 90 E user guide will be useful to you.


CASIO GRAPH 90 E : Download the complete user guide (2856 Ko)

Manual abstract: user guide CASIO GRAPH 90 E

Detailed instructions for use are in the User's Guide.

[. . . ] α-5 E-CON2 Application (English) (GRAPH35+ E) 1 2 3 4 5 6 7 8 9 10 11 12 E-CON2 Overview Using the Setup Wizard Using Advanced Setup Using a Custom Probe Using the MULTIMETER Mode Using Setup Memory Using Program Converter Starting a Sampling Operation Using Sample Data Memory Using the Graph Analysis Tools to Graph Data Graph Analysis Tool Graph Screen Operations Calling E-CON2 Functions from an eActivity E-CON3 Application (English) (GRAPH95, GRAPH75+ E, GRAPH75+, GRAPH75) 1 2 3 4 5 6 7 8 9 10 11 12 E-CON3 Overview Using the Setup Wizard Using Advanced Setup Using a Custom Probe Using the MULTIMETER Mode Using Setup Memory Using Program Converter Starting a Sampling Operation Using Sample Data Memory Using the Graph Analysis Tools to Graph Data Graph Analysis Tool Graph Screen Operations Calling E-CON3 Functions from an eActivity iv Familiarisation — A lire en premier!] [pc] [Mil] [in] [ft] [yd] [fath] [rd] [mile] [n mile] [cm²] [m²] [ha] [km²] [in²] [ft²] [yd²] [acre] [mile²] [cm³] [mL] [L] [m³] [in³] [ft³] [fl_oz(UK)] [fl_oz(US)] [gal(US)] [gal(UK)] [pt] [qt] [tsp] TIME TMPR VELO MASS RORC PRES ENGY tbsp cup ns μs ms s min h day week yr s-yr t-yr °C K °F °R m/s km/h knot ft/s mile/h u mg g kg mton oz lb slug ton(short) ton(long) N lbf tonf dyne kgf Pa kPa mmH 2 O mmHg atm inH 2O inHg lbf/in² bar kgf/cm² eV J calth cal15 calIT kcalth kcal15 kcalIT I-atm kW• h ft• lbf Btu erg kgf• m [tbsp] [cup] [ns] [μs] [ms] [s] [min] [h] [day] [week] [yr] [s-yr] [t-yr] [°C] [K] [°F] [°R] [m/s] [km/h] [knot] [ft/s] [mile/h] [u] [mg] [g] [kg] [mton] [oz] [lb] [slug] [ton(short)] [ton(long)] [N] [lbf] [tonf] [dyne] [kgf] [Pa] [kPa] [mmH 2 O] [mmHg] [atm] [inH 2 O] [inHg] [lbf/in²] [bar] [kgf/cm²] [eV] [J] [cal th ] [cal15 ] [cal IT] [kcal th ] [kcal 15 ] [kcal IT] [I-atm] [kW• h] [ft • lbf] [Btu] [erg] [kgf • m] 8-40 PWR W calth /s hp ft• lbf/s Btu/min HYP PROB sinh cosh tanh sinh –1 cosh –1 tanh –1 X!€ Unless specifically indicated otherwise, all page references in this “E-CON2 Application” chapter are to pages in this chapter. 1-1 E-CON2 Overview 1 E-CON2 Overview • From the Main Menu, select E-CON2 to enter the E-CON2 Mode. [. . . ] € Unless specifically indicated otherwise, all page references in this “E-CON3 Application” chapter are to pages in this chapter. * For information about CMA and the CLAB Data Logger, visit http://cma-science. 1-1 E-CON3 Overview 1 E-CON3 Overview • From the Main Menu, select E-CON3 to enter the E-CON3 Mode. E-CON3 Main Menu • The “E-CON3 Mode” provides the functions listed below for simple and more efficient data sampling using a Data Logger. € This function can be used to convert Data Logger setup data configured using E-CON3 to a Data Logger control program that can run on the fx-9860G SD/fx-9860G. € It also can be used to convert data to a program that can be run on a CFX-9850 Series/fx-7400 Series calculator. € Pressing the K key (Setup Preview) or a cursor key while the E-CON3 main menu is on the screen displays a preview dialog box that shows the contents of the setup in the current setup memory area. Note For details about setup data and the current setup memory area, see “6 Using Setup Memory” (page 6-1). About online help Pressing the 6(HELP) key displays online help about the E-CON3 Mode. 2-1 Using the Setup Wizard 2 Using the Setup Wizard This section explains how to use the Setup Wizard to configure the Data Logger setup quickly and easily simply by replying to questions as they appear. If you need more control over specific sampling parameters, you should consider using the Advanced Setup procedure on page 3-1. K Setup Wizard Parameters Setup Wizard lets you make changes to the following three Data Logger basic sampling parameters using an interactive wizard format. € Sampling Time Unit (Select Unit): Specify seconds (sec), minutes (min), hours (hour), or days (day) as the time unit of the value you input for the total sampling time (Total Sampling Time). note For some sensors (EA-200 built-in microphone , Vernier Photogate , etc. The differences between sampling parameters and setup procedures for each sensor are described in this section. Setup Wizard Rules Note the following rules whenever you use the Setup Wizard. 2-2 Using the Setup Wizard u To configure a Data Logger setup using Setup Wizard Before getting started. € Before starting the procedure below, make sure you first decide if you want to start sampling immediately using the setup you configure with Setup Wizard, or if you want to store the setup for later sampling. € See sections 6-1, 7-1, and 8-1 of this chapter (E-CON3 Application) for information about procedures required to start sampling and to store a setup. We recommend that you read through the entire procedure first, referencing the other sections and pages as noted, before actually trying to perform it. € To terminate Setup Wizard part way through and cancel the setup, press !€ This launches the Setup Wizard and displays the “Select Sensor” screen. [. . . ] Press the function key that corresponds to the View Window parameter you want to configure. function Key 1(Auto) 2(FULL) 3(Y) Description Automatically applies the following View Window parameters. Y-axis Elements: In accordance with screen size X-axis Elements: In accordance with screen size when 1 data item equals 1 dot; 1 data equals 1 dot in other cases Resizes the graph so all of it fits in the screen. Resizes the graph so all of it fits in the screen along the Y-axis, without changing the X-axis dimensions. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CASIO GRAPH 90 E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CASIO GRAPH 90 E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.