[. . . ] BENSHAW
REDISTART MICRO II INSTRUCTION MANUAL MVRSM12/18 SERIES
Solid State Motor Control
Technology
Publication #: 890015-01-08
The Leader In
TABLE OF CONTENTS
Table of Contents 1. 42 43 44 44 45 45 45 45 46 46 46 47 47
5. 2 PROGRAMMING: Quick Start . 50 50 50 51 51
ii
TABLE OF CONTENTS
5. 6 PROGRAMMING: Starter Setup - Forward2 Profile . 52 52 52 52 53 53 54 54 54 54 55 55 56 56 56 57 57
5. 7 PROGRAMMING: Starter Setup - Tachometer Setup . [. . . ] This means that decel level #1 is not set as a percentage of actual line voltage. If the motor initially surges when a stop is commanded, decrease this parameter value. If there is a sudden drop in motor speed when a stop is commanded, increase this parameter value. Values The decel level #1 is adjustable from 10% to 100% in 1% increments. The decel level #1 setting must be greater than the decel level #2 setting. The default value for the decel level #1 parameter is 40%.
Default
V Level #2
Description The V Level #2 parameter sets the ending voltage for the voltage ramp profile. This means that decel level #2 is not set as a percentage of actual line voltage. If the motor stops rotating before the deceleration time has expired, increase this parameter value. If the motor is still rotating when the deceleration time has expired, decrease this parameter value. Values The decel level #2 parameter is adjustable from 1% to 99% in 1% increments. The default value for the decel level #2 parameter is 20%.
Default
V DCL Time (decel time)
Description The V DCL Time parameter sets the amount of time taken to go from the decel level #1 setting to the decel level #2 setting. If the motor stops rotating before the decel time has expired, decrease the decel time. If the motor is still rotating when the decel time expires, increase the decel time. Values Default The decel time parameter is adjustable from 0 to 60 seconds in 1 second intervals. The default value for the decel time parameter is 0 seconds.
56
5. 8 PROGRAMMING: Starter Setup - Decel Setup
TT DCL Tim (TruTorque deceleration time)
Description The TruTorque deceleration time sets how quickly the motor decelerates. To make the motor decelerate at a slower rate increase this time or to make the motor stop quicker decrease this time. The TruTorque deceleration time parameter is adjustable from 0 to 100 seconds in 1 second intervals The default TruTorque deceleration time is 0 seconds.
Values Default
TT DCL Tor (ending deceleration torque)
Description The value sets the final torque level for the Trutorque deceleration ramp. If the motor is coming to a stop too quickly or if the starter continues to apply current to the motor after the motor has stopped this parameter can be increased in 5% increments. If the motor is still rotating when the desired deceleration time has expired, decrease this parameter by 5% and retest. Values Default The TruTorque deceleration ending torque value can be set from 1% to 100% torque in 1% steps. The default TruTorque deceleration ending torque setting is 10%
57
5. 9 PROGRAMMING: Starter Setup - PORT CTL Setup
Fault Dly (Fault Delay)
Description The Fault Dly parameter determines how long a power disturbance can exist before the micro system will fualt out on a power loss; and no longer restart. If the Fault Dly parameter is set to OFF, the PORT detection wil be disabled and the standard motor protection features will be enabled. [. . . ] INPUT
112
7. 1 DRAWINGS
RediStart Micro II Four (4) Relay Card Layout
TB2 RELAY OUTPUTS
1 24
TB1 CARD POWER
1 2
J1 RIBBON CABLE CONNECTOR
RediStart Micro II Seven (7) Relay Card Layout
K1 Relay
1 2 3
K2 Relay
4 5 6
K3 Relay
7 8 9
K4 Relay
10 11 12
K5 Relay
13 14 15
K6 Relay
16 17 18
K7 Relay
19 20 21
K1
K2
K3
K4
K5
K6
K7
HOT 1 2 3 4 NEUTRAL
FU1 J1
TB3 120Vac Connector
J1 Ribbon Cable Connector
113
7. 1 DRAWINGS
RediStart Micro II RS-232 Communications Card Layout
RECEIVE LED TRANSMIT LED
RIBBON CABLE CONNECTOR TO COMPUTER CARD
LED1 RXD
LED2 TXD
RS-232 IC
RS232 CARD
J2
TB1
9-PIN SUB-D MALE DCE PINOUT RS-232 CONNECTORS
TXD C COM RXD
RediStart Micro II RS-485 Communications Card Layout
RECEIVE LED TRANSMIT LED
DRIVER ENABLE
RIBBON CABLE CONNECTOR TO COMPUTER CARD
LED1 RXD
LED3 DE
LED2 TXD
RS485 CARD
RS-485 IC
TB1
J3
B(+) COM A(-) RS-485 CONNECTORS
9-PIN SUB-D FEMALE
114
7. 1 DRAWINGS
RediStart Micro II RS-232/485 Communications Card Layout
RIBBON CABLE CONNECTOR TO COMPUTER CARD
TRANSMIT LED RECEIVE LED
120 OHM TERM SHIELD TO COM
RS-485 CONFIGURATION SWITCHES
RS-485 TERMINAL BLOCK RS-232 CONNECTOR 9 PIN, SUB-D, FEMALE DCE PINOUT
Modbus Master Card (for Remote RTD Module)
24VDC FROM POWER CARD
J3 Gnd+24V
24VDC POWER SUPPLY
Com +24V J8 DE TxD RxD
REMOTE RTD MODULE CONNECTOR
A B Com Shield J6
D4
D5
D6
J7
CPU J1
Display J2 U3
RECEIVE TRANSMIT DEVICE ENABLE
U6
CPU RIBBON CABLE CONNECTOR
J5 U5 U7
DISPLAY RIBBON CABLE CONNECTOR
810007 02-00
U1
U4
D3 LED1
D2 LED2
UJ1 UJ2
VALID SLAVE RESPONSE STATUS
115
7. 1 DRAWINGS
RediStart Micro II Display Cut-out
2 27/32"
MICRO DISPLAY CUT-OUT TEMPLATE (May not print to scale)
2 15/16"
CUT-OUT SIZE: 5-3/8" x 2-5/8" HOLE PATTERN: 5-11/16" x 2-15/16" HOLE SIZE: 3/16"
5 11/16"
116
8.
PARAMETER LIST
8. 1 Parameter List
RediStart Micro II Parameter List
General The following pages list the menu parameters for the RediStart Micro II. The list gives the page number where information on the parameter can be found. The list can also be used to record the values that are programmed into the RediStart Micro II for the installation. Each line lists the parameter, page reference, blank, and default setting. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BENSHAW MVRSM12