User manual AEG-ELECTROLUX LUX TX1500B

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX LUX TX1500B. We hope that this AEG-ELECTROLUX LUX TX1500B user guide will be useful to you.


AEG-ELECTROLUX LUX TX1500B : Download the complete user guide (335 Ko)

You may also download the following manuals related to this product:

   AEG-ELECTROLUX LUX TX1500B (393 ko)

Manual abstract: user guide AEG-ELECTROLUX LUX TX1500B

Detailed instructions for use are in the User's Guide.

[. . . ] Laurel, New Jersey 08054, USA WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only Energizer is a registered trademark of Eveready Battery Company, Inc. DURACELL® is a registered trademark of The Gillette Company, Inc. ® INSTALLATION 52017 Complete, Easy To Read Programming And Installation Instructions Inside Please read all instructions carefully before beginning installation. TOOLS REQUIRED #1 Phillips screwdriver (small) Drill with 3/16-in. (4. 8mm) bit I M P O RTA N T ! READ INSTALLATION INSTRUCTIONS FIRST Thank you for your confidence in our product. To obtain the best results from your investment, please read these instructions and acquaint yourself with your purchase before installing your new thermostat. [. . . ] ALL RIGHTS RESERVED Base Terminals G Y W RH B O RC R W Latch Button If you are mounting the base to a soft material like plasterboard or if you are using the old mounting holes, the screws may not hold. (4. 8mm) hole at each screw location, and insert the plastic anchors provided. Then mount the base as described below. NOTE TYPICAL HOOKUP FOR 2-WIRE 24V HEATING SYSTEM AND MILLIVOLT SYSTEM G Y W RH B O RC TYPICAL HOOKUP FOR 3-WIRE HEAT SYSTEM IF THIRD WIRE IS FAN WIRE G Y W RH B O RC TYPICAL COOLING AND HEATING SYSTEM (4-WIRE) G Y W RH B O RC GAS VALVE FAN 24 VAC TRANSFORMER OR THERMOPILE 110 Figure 8 GAS VALVE FAN GAS VALVE G COOL COMP 24 VAC TRANSFORMER 110 Figure 9 24 VAC HEAT TRANSFORMER 110 Figure 10 ATTACHING WIRES 4. Hold the base against the wall, with the wires coming through wherever it is convenient for wiring. Position the base for best appearance (to hide any marks from an old thermostat). Attach the base to the wall with the two screws provided. TYPICAL COOLING AND HEATING SYSTEM (5-WIRE) G Y W RH B O RC TYPICAL SINGLE-STAGE HEAT PUMP WIRING G Y W RH B O RC FAN GAS VALVE FAN REMOVE JUMPER BETWEEN RH & RC ADD JUMPER BETWEEN Y&W ALT. CHG. OVER COOL COMP COMP 24 VAC HEAT TRANSFORMER 110 24 VAC COOL TRANSFORMER Figure 11 24 VAC HEAT TRANSFORMER 110 Figure 12 110 Do not allow wires to touch each other or parts on thermostat. Also, be sure to tighten securely all 7 electrical terminal screws. C A U T I O N If you have an electric system and the blower does not operate after installation, find the electric/gas heat selector on the back of the body. Move the selector to the ELEC position. NOTE WIRING DIAGRAMS Heating Systems FAN RELAY COOLING COMPRESSOR HEATING CONTROL HEATING TRANSFORMER DAMPER OR CHANGEOVER VALVE (POWERED IN HEAT) INSTALLING BATTERIES/ MAINTENANCE The TX1500 requires batteries to operate your furnace and retain its programming in memory and to light the display. Replace the batteries when the REPLACE indicator appears in the display or at least once a year. Cooling Systems FAN RELAY COOLING COMPRESSOR HEATING CONTROL HEATING TRANSFORMER DAMPER OR CHANGEOVER VALVE (POWERED IN HEAT) REPLACE When replacing batteries, you have approximately 1 minute before programs are lost. Heat Selector SW1 ELECT RL1 GAS 5/2 MIN ON/OFF C/F 24/12H NOTE DAMPER OR CHANGEOVER VALVE (POWERED IN COOL) DAMPER OR CHANGEOVER VALVE (POWERED IN COOL) COOL TRANSFORMER COOL TRANSFORMER G Y W RH B O RC G Y W RH B O RC REPLACE BATTERIES WHEN INDICATOR APPEARS OR AT LEAST ONCE A YEAR. Tape Off Tape Off ** 4 H 5 V Tape Off * Tape Off C G G F R* B * Y V R TC C RH W RC F * If replacing a Honeywell TM-11, tape off wire "R"; connect wire "B" to terminal "RH. " ** If replacing a Honeywell thermostat with a clock wire "C, " tape off wire "C" Heating/Cooling Systems 4- or 5-Wire with One Transformer FAN RELAY COOLING COMPRESSOR HEATING CONTROL HEATING TRANSFORMER DAMPER OR CHANGEOVER VALVE (POWERED IN HEAT) * If both Y and C wire are present, tape off "C" wire. * If you have a "B" wire in your system which is used as a common wire, connecting it to the "B" terminal on this thermostat may damage your system and/or the thermostat. Heating/Cooling Systems 5- or 6-Wire with Two Transformers FAN RELAY COOLING COMPRESSOR HEATING CONTROL HEATING TRANSFORMER DAMPER OR CHANGEOVER VALVE (POWERED IN HEAT) RC TC 1. Install two new Energizer® or DURACELL® "AA" size alkaline batteries in the battery compartment. Place body back on wall. Battery Compartment WARNING: Use Energizer ® or DURACELL ® Alkaline Batteries Only. 5. Hook the top of the body onto the base, swing the body down and snap the body onto the base. Be sure to turn the power back on to your heating and /or air conditioning system. If this is the first time you are installing batteries, the thermostat will display "SUN 12:00 AM". Within 90 seconds the thermostat will begin to display the room temperature alternately with the time. The set point temperature will appear in the right side of the display. In the winter, set the system switch to HEAT to control your heating system. In the summer, set the switch to COOL to control your air conditioner. In spring and fall or when windows are open, you can set the system switch OFF. [. . . ] Located to the right of the gas electric switch are two black jumpers C/F and 24/12H. ELECT GAS Press the reset key on the front of the thermostat for RL1 5/2 MIN C/F ON/OFF changes to take effect. · · · · · Open the drop down door on the front of the thermostat. You should see the display pictured above with a day of the week flashing. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX LUX TX1500B




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX LUX TX1500B will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.