User manual AEG-ELECTROLUX LUX T401143SA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX LUX T401143SA. We hope that this AEG-ELECTROLUX LUX T401143SA user guide will be useful to you.


AEG-ELECTROLUX LUX T401143SA : Download the complete user guide (227 Ko)

Manual abstract: user guide AEG-ELECTROLUX LUX T401143SA

Detailed instructions for use are in the User's Guide.

[. . . ] Make note of wires and to which terminals they are attached as you disconnect them. For example: "Yellow wire to terminal Y, Red wire to terminal RH, " etc. [. . . ] Do not locate in unusual cooling conditions, such as on an outside wall, or one separating an unheated room, or in drafts from stairwells, doors, or windows. Do not locate where air circulation is poor, such as in a corner, alcove, or behind an open door. Do not install until all construction work and painting have been completed. G COOLING COMPRESSOR HEATING CONTROL HEATING TRANSFORMER DAMPER OR CHANGEOVER VALVE (POWERED IN HEAT) DAMPER OR CHANGEOVER VALVE (POWERED IN COOL) DAMPER OR CHANGEOVER VALVE (POWERED IN COOL) COOL TRANSFORMER COOL TRANSFORMER Y W RH B O RC G Y W RH B O RC Tape Off Tape Off ** 4 5 Tape Off * Tape Off C G G F R* B RH TC C W RC Y F * If replacing a Honeywell TM-11, tape off wire "R"; connect wire "B" to terminal "RH. " ** If replacing a Honeywell thermostat with a clock wire "C, " tape off wire "C" Heating/Cooling Systems 4- or 5-Wire with One Transformer FAN RELAY COOLING COMPRESSOR HEATING CONTROL HEATING TRANSFORMER DAMPER OR CHANGEOVER VALVE (POWERED IN HEAT) * If both Y and C wire are present, tape off "C" wire. Heating/Cooling Systems 5- or 6-Wire with Two Transformers FAN RELAY COOLING COMPRESSOR HEATING CONTROL HEATING TRANSFORMER DAMPER OR CHANGEOVER VALVE (POWERED IN HEAT) DAMPER OR CHANGEOVER VALVE (POWERED IN COOL) DAMPER OR CHANGEOVER VALVE (POWERED IN COOL) COOL TRANSFORMER COOL TRANSFORMER G Y W RH B O RC G Y W RH B O RC 2) TOOLS REQUIRED V RC B O H V * V R TC V R RC A (Optional) (Optional) C 4 Wirestripper or knife, drill with 3/16" bit, screwdriver, level and a pencil. F Y * C O Tape Off Tape Off F * Y B RC (Optional) (Optional) TC * If both Y and C wire are present, tape off "C" wire. * If both Y and C wire are present, tape off "C" wire. © COPYRIGHT 2006 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED W G TC G RH W R These diagrams below are provided for new installations or unreferenced wires. FIGURE 3 SUB-BASE FIGURE 4 DECORATIVE WALL PLATE horiz TYPICAL HOOKUP FOR 2-WIRE 24V HEATING SYSTEM AND MILLIVOLT SYSTEM G Y W RH B O RC TYPICAL HOOKUP FOR 3-WIRE HEAT SYSTEM IF THIRD WIRE IS FAN WIRE G Y W RH B O RC TYPICAL COOLING AND HEATING SYSTEM (4-WIRE) G Y W RH B O RC UP vert UP O GAS VALVE FAN 24 VAC TRANSFORMER OR THERMOPILE 110 Figure 8 GAS VALVE FAN GAS VALVE RH G RC COOL COMP 24 VAC TRANSFORMER 110 Figure 9 A 24 VAC HEAT TRANSFORMER 110 Figure 10 B Y W TYPICAL COOLING AND HEATING SYSTEM (5-WIRE) G Y W RH B O RC TYPICAL SINGLE-STAGE HEAT PUMP WIRING G Y W RH B O RC FAN GAS VALVE FAN REMOVE JUMPER BETWEEN RH & RC ADD JUMPER BETWEEN Y&W ALT. CHG. OVER COOL COMP COMP 24 VAC HEAT TRANSFORMER 110 24 VAC COOL TRANSFORMER Figure 11 TECHNICAL ASSISTANCE 24 VAC HEAT TRANSFORMER 110 Figure 12 110 If you have an electric system and the blower does not operate after installation, find the factory installed yellow wire currently attached to the "Y" terminal and move it to the "A" terminal on the sub-base. Place Base, Figure 3, over Sub-Base and attach by tightening three captive screws. Place a level against the bottom of the Base, adjust until it is level and then tighten mounting screws to secure. Do this by carefully sliding the long pointer , Figure 2, over desired number printed on the anticipator. If old anticipator setting cannot be determined, look on gas control on furnace, or set at at . 6. During heating season, furnace should operate about five times an hour. If adjustments are necessary, move heat anticipator pointer slightly and recheck. Turn electricity and gas back on and set pointer on top of thermostat to desired temperature. [. . . ] only. FIGURE 1 FRONT COVER FIGURE 2 BASE MOUNTING HOLE UP ANTICIPATOR R GE . 2 LON . 1 5 . 3 . 4 LONG POINTER CAPTIVE SCREW RECYCLING NOTICE . 12 HOLES FOR WIRES CAPTIVE SCREW MOUNTING HOLE This product does not contain mercury. However, this product may replace a unit which contains mercury and should not be disposed of in the trash. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX LUX T401143SA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX LUX T401143SA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.