User manual AEG-ELECTROLUX LUX DMH110

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX LUX DMH110. We hope that this AEG-ELECTROLUX LUX DMH110 user guide will be useful to you.


AEG-ELECTROLUX LUX DMH110 : Download the complete user guide (358 Ko)

You may also download the following manuals related to this product:

   AEG-ELECTROLUX LUX DMH110 (370 ko)

Manual abstract: user guide AEG-ELECTROLUX LUX DMH110

Detailed instructions for use are in the User's Guide.

[. . . ] NOTE: When the system mode switch is in the OFF position, it is normal for the system's blower fan ("G" terminal if used) to still become activated depending upon the position of the FAN mode switch (see below). SYSTEM MODE SWITCH: A/C COMPRESSOR GAS VALVE OR HEATER FAN + SYSTEM XFMR LUX PRODUCTS CORPORATION Mt. Laurel, New Jersey 08054, USA 52011 TYPICAL 2-TRANSFORMER 5-WIRE SINGLE STAGE 24 VOLT HEATING & COOLING SYSTEMS *Jumper REMOVED WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only. Energizer® is a registered trademark of Eveready Battery Company, Inc. DURACELL® is a registered trademark of The Gillette Company, Inc. O B Y W RH RC G C Optional Common Lead Please read all instructions carefully before beginning installation and save for future reference. Before removing any wiring from your existing thermostat, the wires must be labeled with their terminal designations. [. . . ] "SAVE" will remain visible until the "SAVE" mode is cancelled. To Adjust SAVE Temperature In "SAVE" mode "SAVE" will be visible in the display Press UP or DOWN button The save temperature will be displayed flashing. The flashing the "SAVE" temperature may be changed with the UP/DOWN buttons. After 5 seconds with no button presses, the displayed "SAVE" temperature will be used as the set temperature, and ambient temperature will be returned to the display. The "SAVE" indicator will be extinguished and the comfort temperature will be displayed flashing. The flashing comfort set temperature may be changed with the UP/DOWN buttons. After 5 seconds with no button presses, the comfort temperature will be made the new set temperature, and ambient temperature will be returned to the display. Save Button HEATING ONLY SYSTEMS JUMPER PROVIDED COOLING ONLY SYSTEMS JUMPER PROVIDED 1 Stage Heat / 1 Stage Cool Electronic Digital - Non Programmable Innovative "SAVE" feature Gas / Electric Blower Option Battery Powered Setting Temperature Range 45°F to 90°F Clean, Attractive Design Easy To Install EL (Electro Luminescent) Backlight Display Large, Easy To Read Display F/C Selectable Temperature Display Adjustable Temperature Differential / Cycle Rate User Temperature Offset / Display Calibration 5/2 Minute Selectable Minimum Run/Off Time for Short Cycle / Compressor Protection On-Screen Low Battery Indicator 1 Year Warranty O B Y W RH RC G C O B Y W RH RC G C COMPLETING YOUR INSTALLATION C W R RH V 5 G C Y RC R V 5 G 7. Please review the "SETUP OPTIONS" section to configure the thermostat's options. NOTE: Before use, remove the plastic film (if present) that is protecting the LCD display screen. Install two (2) Energizer® or DURACELL® "AA" size Alkaline Batteries at this time. **For instructions on installing the batteries, see the "BATTERIES AND MAINTENANCE" section. To do this, line up the tabs on all four corners and gently push the unit straight onto the base. Do not use unnecessary force if the body does not snap into place easily. 10. Turn the electrical power back ON to both your heating and/or air conditioning systems. 11. Verify that both systems (and the blower fan) are operating properly. When set to a high temperature, the heating system should provide warm air after a short time in Heat Mode. Likewise, a cooling system should provide cool air after a short time when set to a low temperature in Cool Mode. Usually, sound from the furnace and air conditioning units can be heard while either of them is running. The rush of moving air should be heard within a short time after either has been started. NOTE: If you have an Electric Heat system and the blower does not operate after installation, locate the "Gas/Electric" option inside the back of the thermostat. Move the jumper to the "Electric" position. OPTIONAL OPTIONAL F F HEATING / COOLING SYSTEMS 4 & 5 WIRE WITH ONE TRANSFORMER JUMPER PROVIDED HEATING / COOLING SYSTEMS 5 & 6 WIRE WITH TWO TRANSFORMERS JUMPER REMOVED OPTIONAL H 4 B* TC C* 6 B* TC DISPLAY ILLUMINATION: Pressing any button will illuminate the display for easier viewing in dim light conditions. While the light is illuminated, pressing any of the three push buttons will continue the lighting and remain on for approximately 10 more seconds. O B Y W RH RC G C O B Y W RH RC G C Y W OPTIONAL F R F CAUTION: The DMH110 is protected against normal static electric discharges. [. . . ] This warranty gives you specific legal rights and you may also have other rights which vary from state to state. only. TYPICAL 3-WIRE 24 VOLT COOLING ONLY SYSTEMS *Jumper Provided JP2 - FAHRENHEIT OR CELSIUS DISPLAY FORMAT This setting controls whether the temperature is displayed in degrees °F or °C on the LCD screen. O B Y W RH RC G C Optional Common Lead JP3 - TEMPERATURE SWING SETTING This setting changes the size of the temperature control band with respect to the set point. The larger the swing setting, the larger the temperature control range will be. Conversely, the smaller the swing setting, the smaller (or tighter) the temperature control range will be. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX LUX DMH110




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX LUX DMH110 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.