User manual AEG-ELECTROLUX EFCR950X

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX EFCR950X. We hope that this AEG-ELECTROLUX EFCR950X user guide will be useful to you.


AEG-ELECTROLUX EFCR950X : Download the complete user guide (830 Ko)

You may also download the following manuals related to this product:

   AEG-ELECTROLUX EFCR950X (132 ko)
   AEG-ELECTROLUX EFCR950X (831 ko)
   AEG-ELECTROLUX EFCR950X (2309 ko)

Manual abstract: user guide AEG-ELECTROLUX EFCR950X

Detailed instructions for use are in the User's Guide.

[. . . ] · Since the rule for rooms with fuel burning appliances is "outlet hole of the same size as the ventilation hole", a hole of 500-600 cm2, which 33 is to say a larger hole, could reduce the performance of the extractor hood. · If the hood is used in its filtering function, it will operate simply and safely in the above conditions without the need for any of the aforementioned measures. · When the hood is used in its extractor function, the following rules must be followed to obtain optimal operation: -- short and straight outlet hose -- keep bends in outlet hose to a minimum -- never install the hoses with an acute angle, they must always follow a gentle curve only -- keep the hose as large as possible (preferably the same diameter as the outlet hole). · Failure to observe these basic instructions will drastically reduce the performance and increase the noise levels of the extractor hood. for the user · Always cover lighted elements, to prevent excess heat from damaging the appliance. [. . . ] · The air is discharged to the outside through a pipe, which must be fitted to connection flange D. · In order to obtain the best performance the hose should have a diameter equal to the outlet hole. Should there already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof, it is possible to use the 150/125 mm reduction flange provided. 1 Filter Version · The air is filtered through a charcoal filter and returned to the kitchen through the top grill of the outlet pipe. · You will need an original ELECTROLUX KF20 charcoal filter for the filtering function. 2 34 Control Panel · The hood is fitted with one motor having several speed. Turn the hood on a few minutes before you start cooking, you will then get an under pressure in the kitchen. The hood should be left on after cooking for about 15 minutes or until all the odours have disappeared. The control switches are located on the unit's front panel: · the light switch switches the hood lamp ON and OFF; · ON/OFF Extractor fan switch - Push-button 1: used to turn the fan off and to set the fan to speed 1. · Push-button 3: used to set the fan to speed 3. ON/OFF Extractor fan switch Push-button 1 Light switch Push-button 2 Push-button 3 Fig. 3 Correct ventilation If the cooker hood is to work correctly there must be an under pressure in the kitchen. · Mounting Remove the frame i which supports the filter h by turning 90° the two knobs g, Fig. 5. Insert the charcoal mattress inside the frame and put all parts back in their place. · Always specify the hood model code number and serial number when ordering replacement filters. This information is shown on the registration plate located on the inside of the unit. · The charcoal filter can be ordered from the ELECTROLUX technical assistance service. h g g i g g h Fig. · If the light does not come on, make sure the bulb has been inserted in correctly before contacting the technical assistance service. 3 1 2 Fig. 6 37 Technical Specifications Dimensions (cm) Height Width Depth 85, 8 - 113 99, 8 70 4 x 20 W 1 240 W Lighting Grease filter power absorption We reserve the right to generate constructive and chromatic modifications as required by technological growth. Special accessories Carbon filter KF 20 E-Nr. 942 120 600 Installation Unpacking Check that the cooker hood has no damages. Transportation damages should immediately be reported to the one responsible for the transport Damages, faults and eventually missing details should immediately be reported to the seller. Take care of the packing material so that small children cannot play with it. Min 50 cm Min 65 cm Fig. 7 This disconnector may be for example a switch, fuses (plug fuses must be removed from the fuse box, fault current switches and remote switches with a distance of over 3 mm between contacts. [. . . ] Should it be necessary to provide a fixed connection, the hood must only be installed by an electrician authorised by the local electricity board. When installing, an omnipolar disconnector with a distance of at least 3 mm between contacts must be provided. Installation Mounting accessories included 1 deflector, 6 wood-screws 6 x 70 mm, 6 wall plugs Ø 10 mm, 10 nuts, 8 metal screws 3x9 mm, 6 metal screws 4 x 8 mm, 10 metal screws 3x9 mm, 1 reduction flange Ø 125-120 mm 273 273 244 Wall unit mounting - Fig. 8 - 9 - 10 Expansion plugs are provided to secure the hood to most types of ceilings. However, a qualified technician must verify suitability of the materials in accordance with the type of ceiling. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EFCR950X




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX EFCR950X will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.