User manual AEG-ELECTROLUX EFCR147U

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX EFCR147U. We hope that this AEG-ELECTROLUX EFCR147U user guide will be useful to you.


AEG-ELECTROLUX EFCR147U : Download the complete user guide (455 Ko)

You may also download the following manuals related to this product:

   AEG-ELECTROLUX EFCR147U (434 ko)
   AEG-ELECTROLUX EFCR147U (440 ko)
   AEG-ELECTROLUX EFCR147U (772 ko)

Manual abstract: user guide AEG-ELECTROLUX EFCR147U

Detailed instructions for use are in the User's Guide.

[. . . ] · Ensure that the power cord does not get squeezed at the installation. · The cooker hood is only dead when the plug or the fuse is disconnected. · The cooker hood cannot be connected to flues of other appliances that run on energy sources other than electricity. Please, keep to the provisions of official directives regarding the question of fumes discharge. Use of cooker hood · Never leave any deep-frying, melting fat, paraffin or any other inflammable unattended on the hob. [. . . ] · It is essential that the grease filter is regularly cleaned to avoid fat to drip on to the hot zone and cause fire. Read also the part "Maintenance and Cleaning" in the instruction book. Disposal · Prevent accidents when disposing your cooker hood. Disconnect the power plug from the wall socket and cut the power cord at the hood inlet. Contact your local authority for information on where to dispose the cooker hood. 2 Description of the cooker hood The cooker hood 1 Control panel 2 Grease filter 3 Lamps 4 Chimney Functions There are two possible systems: · Extraction of air to outside using optional venting kit and evacuation duct (remove the carbon filter). · Recirculation using carbon filter (already fitted with the hood). 1 Accessories 3 2 3 The cooker hood cannot be connected to flues of other appliances that run on energy sources other than electricity. Please, keep to the provisions of official directives regarding the question of fumes discharge. The following are included with the cooker hood (Fig. 1): · Screws for mounting · Template · Non return fume valve (mounted in the outlet hole) Using the cooker hood The control panel Best results are obtained by using low speed for normal conditions and high speed when smells and steam are more concentrated. Turn the hood on a few minutes before you start cooking then you will get an underpressure in the kitchen. It should be left on after cooking for about 15 minutes or until all steam and smells have disappeared. 2 to know the functions of the Control Panel A ­ Motor OFF button B ­ ON button and motor speed selection button 1 - 2 - 3 1 -2- . Be sure you have the product number and model name at hand when ordering service or parts. Technical data Model Size Height Width Depth EFC 008 X 800-1200 mm 998 mm 700 mm Max 4x20 W 2 pcs. 230 V 215 W Light Grease filter Voltage Total power Installation Unpacking Check that the cooker hood is not damaged. Transportation damages should immediately be reported to the transport company. Damages, faults and eventually missing parts should immediately be reported to the retailer. Dispose carefully of the packaging material so that it is out of the way of small children. Electrical connection The electric outlet should be placed inside the chimney. The hood has a power cord and moulded plug with earth connection for a wall outlet of 230V. Position The cooker hood should be mounted freely hanging on the wall. The cooker hood must be at least 60 cm above electric burners or electric range, or at least 75 cm above gas burners or gas range. 6 Mounting the cooker hood Expansion plugs are provided to secure the hood to most types of ceilings. A qualified technician is needed, however, to make sure that the plugs are suitable for your ceiling. The ceiling must be strong enough to hold the weight of the hood. B A Fig. 7 Preliminary operations: Assembly the cooker hood support structure using the brackets supplied (Fig. 7): Using all brackets, hood can have an height extension from a minimum of 100cm to a maximum of 120cm; for minor extension, do not use brackets B, in this way hood can have an height extension from a minimum of 80cm to a maximum of 100cm. 1 (Ø 150mm Extraction of air or Recirculation) (Ø 120mm Recirculation) 1 1. [. . . ] Exhaust tube of Ø150mm can be used for Extraction of air or Recirculation while exhaust tube of Ø 120 mm can be used only in Extraction of air and by mounting an adapter on the connection ring. Fig. Fit the template supplied on the ceiling vertically to the centre of the cooktop (the short sides of the template correspond to the long side of the hood-to consider when drilling). Drill asindicatedandinsert 4wallplugs, screw onit4screws, do not thighten completely, screws will serve to hang the hood. 10. 4 3 8 4 6 5 10 10 10 7 5 9 5 6 7 5 10 6 9 (Umluftbetrieb!) (Recirculation!) Fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EFCR147U




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX EFCR147U will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.