User manual AEG-ELECTROLUX DC 2000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX DC 2000. We hope that this AEG-ELECTROLUX DC 2000 user guide will be useful to you.


AEG-ELECTROLUX DC 2000 : Download the complete user guide (125 Ko)

Manual abstract: user guide AEG-ELECTROLUX DC 2000

Detailed instructions for use are in the User's Guide.

[. . . ] Operating Instructions Switch Mode Power Supply AC 2000 / DC 2000 AEG Power Solutions GmbH Department: TD Name: Schenuit Alteration state: 08 Date: 23. 08. 2004 Operating Instructions 0206 BAL, en Switch Mode Power Supply AC 2000 / DC 2000 Table of Contents Notes on these operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1. 5. 1 5. 2 5. 2. 1 5. 2. 2 5. 2. 3 5. 2. 4 5. 2. 5 5. 2. 6 5. 3 5. 3. 1 5. 3. 2 5. 3. 3 5. 3. 4 6. 12. 1 12. 2 Safety Regulations!. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Important Instructions and Explanations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Accident Prevention Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Qualified Personnel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Type Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Circuit diagram AC 2000 / DC 2000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Electrical Principle of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Safe Electrical Isolation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Dynamic Response of the Output Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Emitted Interference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Setting the Output Voltage and the Output Current . . . . . . . . . . . . . . . 11 Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Mains Monitoring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Output Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Reset Buttons/Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Signalling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Parallel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Separate Networks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Signal Interface (X11). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 External On/Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 External Sensor Lead Output Voltage UA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 External Set Value Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Fault Location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 No Output Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Deviation of the Output Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Technical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 General Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Technical Data of the AC 2000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Technical Data of the DC 2000 Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Dimension Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Dimension drawing for DC 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Dimension drawing for AC 2000 over 24 V DC. . . . . . . . . . . . . . . . . . . . . . 15 Page 2 of 21 0206 BAL, en Switch Mode Power Supply AC 2000 / DC 2000 Notes on these operating instructions Instruction Obligation These operating instructions must be read carefully by all persons working with or on the switch mode power supply prior to installation and initial start-up. These operating instructions are a composite part of the switch mode power supply. [. . . ] Procedure: Disconnect the load and the battery, if applicable, on the output. Page 11 of 21 0206 BAL, en i Switch Mode Power Supply AC 2000 / DC 2000 - Set the required monitoring values with the UA> and UA< potentiometers with a screwdriver: - UA> Adjustment: - set the UA> potentiometer to the far right stop, set UA to the required UA> value, turn the UA> potentiometer to the left until UA> responds - UA< Adjustment: Performed as for UA> adjustment (observe the discharge time of the output capacitors and monitoring delay). Connect the load/battery Set the UA output voltage to the required value with the UA potentiometer. The maximum output current is also adjustable within a limited range with the IA potentiometer. - Procedure: Increase the load until the set current limitation is triggered Adjust the IA potentiometer with a screwdriver (IA smaller when turned to the left). 5. 3 5. 3. 1 Monitoring Mains Monitoring The mains monitoring assembly fulfils various functions. It ensures the intrinsic safety of the unit against overloads and overvoltages with fixed switching point settings. The response values (switching points) are given in the technical data sheet. On Hysteresis (Shutd ow n hysteresis ra ng e) Off U ma ins[V] Overvolta g e Und ervolta g e Figure 3 Mains undervoltage monitoring The unit is switched off if the mains supply drops below the switching point. When the hysteresis voltage is exceeded the unit automatically resumes operation with a "soft start". Page 12 of 21 0206 BAL, en Switch Mode Power Supply AC 2000 / DC 2000 Mains overvoltage monitoring When the maximum permissible mains voltage is exceeded, the SMPS is stopped for the duration of the overvoltage. When the voltage level drops below the hysteresis voltage the unit automatically resumes operation with a "soft start". 5. 3. 2 Output Monitoring The setting potentiometers and the LED indicators for the following monitored functions are located on the front plate: Overtemperature monitoring AC 2000 with deactivation, without latching. When the unit has cooled down it automatically resumes operation with a "soft start". Fault, with deactivation and latching - DC overvoltage indicator UA> - with deactivation and latching (response delay t = 10ms) Adjustment with UA> potentiometer - DC undervoltage indicator UA< - AC2000 without deactivation, without latching DC2000 with deactivation and latching (response delay t = 2. 8 s) Adjustment with UA< potentiometer - Operation indicator lights up when power is supplied 5. 3. 3 Reset Buttons/Functions A fault signal (response of an output monitoring device) can be acknowledged with the "Reset" button. A fault signal can also be acknowledged by switching off the mains voltage or with the external on/off function. 5. 3. 4 Signalling The faults are indicated by LEDs on the front panel and signalled on signal connector X11 as a collective signal via a potential-free relay contact (changeover contact) (refer to circuit diagram). The contact between X11:12 and X11:13 is closed in the event of unit failure. Relay contact load: Umax = 110 V DC Iper < 0. 45 A DC Umax = 60 V DC Iper < 1 A DC Umax = 24 V DC Iper < 8 A DC Maximum isolation from the secondary side: 110 V DC Page 13 of 21 0206 BAL, en Switch Mode Power Supply AC 2000 / DC 2000 6. Parallel Operation Due to the inclination of the voltage step of approximately 1% a load distribution of approximately 10% is achieved in parallel operation of several SMPS units. If load distribution is to be optimized the output voltage of the unit with the lowest load current should be increased and the output voltage of the unit with the highest load current decreased. Selective monitoring of the individual SMPS units is only possible with external isolating diodes in the output. Systems with redundancy As the units can be connected in parallel it is possible to create systems for redundant operation in accordance with the n+1 principle. 7. Separate Networks When the SMPS is connected to separate networks, mains overvoltages must be expected which can last for a period of seconds. For example if rotary converters are used for supply, up to 20% overvoltage over a period of seconds occurs. The mains overvoltage monitoring device (refer to 5. 3. 1) stops the unit for the duration of the overvoltage. 8. 8. 1 Signal Interface (X11) External On/Off The unit can be switched on and off externally via a potential-free contact (contact load 15 V DC/5mA, contact open = "Unit Stop"). To this purpose the bridge on signal connectors X11:7 and X11:8 must be removed and a relay contact looped in (refer to Chapter 5. 1). In the case of positive pole earthing the potential - UA which is now higher (in relation to reference potential) is applied to these inputs. Electrical isolation must therefore be carried out by the external relay. 8. 2 External Sensor Lead Output Voltage UA On all units is possible to compensate a voltage drop of 1 V on both the positive and negative output cables. For compensation on the positive output cable X11:9 is connected to the positive pole of the load, for compensation on the negative output cable X11:10 is connected to the negative pole of the load. If the sensor lead is interrupted the output voltage increases by 1 V. Page 14 of 21 0206 BAL, en Switch Mode Power Supply AC 2000 / DC 2000 8. 3 External Set Value Input The "internal/external" switch is used to switch between the internal and external voltage set value. [. . . ] In the case of an external set value input, is the set value correct? Page 16 of 21 0206 BAL, en Switch Mode Power Supply AC 2000 / DC 2000 11. 11. 1 Technical Data General Technical Data Make current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IU curve in accordance with DIN 41772 or DIN 41773 Emitted interference to EN 50081-1 - Conducted interference . . . . . . . . . . . . . . . to EN 55022 Class "B" - Emission. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . to EN 55022 Class "B" Noise immunity to EN 50082-2 - Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX DC 2000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX DC 2000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.